TROUBLESHOOTING
Reset Operation
Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.
If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not
function correctly contact your heating/cooling service person or place of purchase.
Note: Be sure to review the installer configuration menu settings.
To reset the programming, clock and configuration settings,
press ![]()
and
and the FAN button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.
Symptom | Possible Cause | Correction Action | |
|
|
|
|
No Heat/No Cool/No Fan | 1. | Blown fuse or tripped circuit breaker. | Replace fuse or reset breaker. |
(common problems) | 2. | Furnace power switch to OFF. | Turn switch to ON. |
| 3. | Furnace blower compartment door or | Replace door panel in proper position to engage safety |
|
| panel loose or not properly installed. | interlock or door switch. |
| 4. | Loose connection to thermostat or | Tighten connections. |
|
| system. |
|
|
|
|
|
No Heat | 1. | Pilot light not lit. | |
| 2. | Furnace | Many furnaces have safety devices that shut down when |
|
| may also be intermittent. | a |
|
|
| contact the furnace manufacturer or local HVAC service |
|
|
| person for assistance. |
| 3. | Heating system requires service or | Diagnostic: Set SYSTEM Switch to HEAT and raise the |
|
| thermostat requires replacement. | setpoint above room temperature. Within a few seconds |
|
|
| the thermostat should make a soft click sound. This sound |
|
|
| usually indicates the thermostat is operating properly. If |
|
|
| the thermostat does not click, try the reset operation listed |
|
|
| above. If the thermostat does not click after being reset |
|
|
| contact your heating and cooling service person or place |
|
|
| of purchase for a replacement. If the thermostat clicks, |
|
|
| contact the furnace manufacturer or a HVAC service |
|
|
| person to verify the heating is operating correctly. |
|
|
|
|
No Cool | 1. | Cooling system requires service or | Same as diagnostic for No Heat condition except set the |
|
| thermostat requires replacement. | thermostat to COOL and lower the setpoint below the room |
|
|
| temperature. There may be up to a five minute delay before |
|
|
| the thermostat clicks in Cooling. |
|
|
|
|
| 1. | Possible short in wiring. | Check each wire connection to verify they are not shorted |
Heat, Cool or Fan | 2. | Possible short in thermostat. | or touching together. No bare wire should stick out from |
Runs Constantly | 3. | Possible short in heat/cool/fan system. | under terminal block. Try resetting the thermostat as |
| 4. | FAN Switch set to Fan ON. | described above. If the condition persists, the manufacturer |
|
|
| of your system or service person can instruct you on how |
|
|
| to test the Heat/Cool system for correct operation. If the |
|
|
| system operates correctly, replace the thermostat. |
|
|
|
|
Thermostat Setting & | 1. | Thermostat thermometer setting | The thermometer can be adjusted +/- 4 degrees. See |
Thermostat Thermometer |
| requires adjustment. | Temperature Display Adjustment in the Configuration Menu |
Disagree |
|
| section. |
|
|
|
|
Furnace (Air Conditioner) | 1. | The location of the thermostat and/or | Digital thermostats provide precise control and cycle faster |
Cycles Too Fast or Too |
| the size of the Heating System may | than older mechanical models. The system turns on and off |
Slow (narrow or wide |
| be influencing the cycle rate. | more frequently but runs for a shorter time so there is no |
temperature swing) |
|
| increase in energy use. If you would like an increased cycle |
|
|
| time, choose SL for slow cycle in the Configuration menu, |
|
|
| step 6 (heat), 7 (cool) or 8 (heat pump). If an acceptable |
|
|
| cycle rate is not achieved, contact a local HVAC service |
|
|
| person for additional suggestions. |
|
|
|
|
Forgot Keypad Lockout |
|
| Hold MENU key for 20 seconds and the lockout will reset. |
Code |
|
|
|
|
|
|
|
Thermostat does not have | 1. | Earlier version of thermostat. | Refer to Instruction Sheet |