White Rodgers 1F87-0261 INSTALLER/CONFIGURATION Menu, Select Energy Management Recovery Energy

Page 5

INSTALLER/CONFIGURATION MENU

The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements. To enter the menu: Set your thermostat to OFF

and press the and buttons simultaneously.The display will show the first item in the configuration menu. Press RUN/

HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press PRGM. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.

Configuration Menu

Menu

Press

Displayed

Press

or

Comments

Reference

Key

(Factory

to select from

 

Number

 

Default)

listed options

 

 

 

 

 

 

 

1

and

SS

 

HP

Select Single Stage (SS) or

 

 

 

 

 

Heat Pump (HP, 1 compressor)

 

 

 

 

 

 

2

RUN/HOLD*

CS

 

On

Select Cool Savings Feature On or OFF

 

 

(OFF)

 

 

 

 

 

 

 

 

 

RUN/HOLD*

CS

1, 2, 3, 4, 5, 6

If CS selected On, selects Cool Savings value

 

 

(3)

 

 

 

 

 

 

 

 

 

3

RUN/HOLD*

E

 

OFF

Select Energy Management Recovery On or OFF

 

 

(On)

 

 

 

 

 

 

 

 

4

RUN/HOLD*

CR Heat

FA, SL

Select Adjustable Anticipation, cycle rate,

 

 

(ME)

 

 

Heat Single Stage

 

 

 

 

 

 

5

RUN/HOLD*

CR Cool

 

SL

Select Adjustable Anticipation, cycle rate,

 

 

(FA)

 

 

Cool Single Stage

 

 

 

 

 

 

6

RUN/HOLD*

CL

 

On

Select Compressor lockout OFF or On

 

 

(OFF)

 

 

 

 

 

 

 

 

 

7

RUN/HOLD*

L

 

OFF

Select Display Light On or OFF

 

 

(On)

 

 

 

 

 

 

 

 

8

RUN/HOLD*

Temp

4 LO to

Select temperature display adjustment higher or lower

 

 

(0 HI)

 

4 HI

 

 

 

 

 

 

 

9

RUN/HOLD*

oF

 

oC

Select oF / oC Display (temperature units in Fahrenheit

 

 

 

 

 

or Celsius)

 

 

 

 

 

 

10

RUN/HOLD*

Change Filter

 

On

Select filter replacement indicator OFF or On

 

 

(OFF)

 

 

 

 

 

 

 

 

 

RUN/HOLD*

Change Filter

25 to 1975

If Change Filter selected On, selects time interval for

 

 

(200 h)

 

 

Change Filter Indicator. (in 25 hour increments)

 

 

 

 

 

 

11

RUN/HOLD*

 

 

 

Returns to normal operation

 

 

 

 

 

 

*Press RUN/HOLD to advance to next item or TIME to move backwards to previous item

1)System Configuration - Selects SS (Single Stage) or HP (Heat Pump) operating mode. Default configuration is SS. For Heat Pump operation choose HP.

2)Select CS (Cool Savings™) - With Cool Savings™ enabled, the thermostat will make small adjustments to the Setpoint temperature during periods of high demand to reduce cooling system running time and save energy.

When the cooling system has been running for more than 20 minutes, humidity in the home will be lower and a higher setpoint temperature will feel comfortable. After 20 minutes of run time, the thermostat will start increasing the setpoint temperature in steps of less than one degree as the system continues to run. These adjustments will eventually cause the system to satisfy the thermostat and turn the system off to reduce the energy consumption. When the Cool Savings feature is active and making adjustments, the display will show “Save”. The amount of the adjustments to the setpoint temperature is dependent on the Cool Savings value that is set, 1 being the least adjustment and 6 being the most adjustment. With this feature set to OFF, no change will occur when the cooling system is continuously running during the periods of high demand. Periods of high demand will normally occur during the late afternoon and early evening on the hottest days of the summer.

3)Select Energy Management Recovery - Energy

Management Recovery (E) On enables the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint.

4 & 5) Select Cycle Rate Selection - The factory default setting for Single Stage Heat is Medium Cycle (ME). For Single Stage Cool the default setting is fast (FA). To change

cycle rate, press the and buttons.

The cycle rate differentials for different settings are:

MODE

Fast

Medium

Slow

 

(FA)

(ME)

(SL)

SS Heat

0.6°F

0.8°F

1.2°F

SS Cool

1.2°F

-

1.7°F

6)Select Compressor Lockout CL OFF or ON - Selecting CL On will cause the thermostat to wait 5 minutes between cooling cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the

5

Image 5
Contents Precautions SpecificationsApplications Model Programming ChoiceGAS / Elec Switch InstallationBattery Location Attach Thermostat Base to Wall Terminal Switch SelectionEnergy Management Recovery EMR Wiring DiagramsSystem switch COOL, OFF, HEAT, Emer Thermostat Buttons and SwitchesThermostat Quick Reference DisplaySelect Energy Management Recovery Energy INSTALLER/CONFIGURATION MenuFast Medium Slow SS Heat SS CoolManual Operation OperationCheck Thermostat Operation Programming Your Thermostat ProgrammingPlanning Your Program Entering Your ProgramEnter Cooling Program Check Your ProgrammingReset Operation TroubleshootingPage Page Homeowner Help Line

1F87-0261 specifications

The White Rodgers 1F87-0261 is a sophisticated thermostat designed to improve home heating and cooling efficiency. Known for its reliability and user-friendly features, this model is widely appreciated by homeowners and HVAC professionals alike.

One of the standout features of the 1F87-0261 is its digital display, which allows users to easily read temperature settings and program schedules. The large, backlit screen ensures visibility in various lighting conditions, making it accessible for all users. This thermostat is designed for both 1-stage heating and cooling systems, and it is compatible with multisystem setups, providing flexibility for various home configurations.

The installation process of the White Rodgers 1F87-0261 is straightforward, making it an attractive option for DIY enthusiasts. The thermostat is designed to fit standard wall plates, and the clear instructions facilitate a hassle-free installation. It requires a 24V power source, commonly found in most HVAC systems.

Programming capabilities are another significant advantage of the 1F87-0261. This model offers a seven-day programmable feature, allowing users to set different schedules for each day of the week. The user can adjust temperatures for specific timeframes, ensuring optimal comfort while also saving on energy costs. The temporary hold function enables users to override programmed settings temporarily without affecting the entire schedule.

Energy-saving features are embedded within the thermostat's design. It includes a setpoint limiting option that can restrict temperature adjustments, effectively preventing overuse and contributing to reduced energy bills. Moreover, the programmable strategy encourages users to maintain more efficient temperature settings during off-peak hours when energy costs may be lower.

With an emphasis on convenience, the White Rodgers 1F87-0261 offers an intuitive interface that simplifies the programming and adjustment of temperature settings. The thermostat also boasts of a maintenance reminder feature, which alerts users when it’s time for routine HVAC system checks, thereby enhancing system longevity.

In conclusion, the White Rodgers 1F87-0261 combines user-friendly programming, energy-saving capabilities, and compatibility with a range of HVAC systems. Its practical design and innovative features make it an ideal choice for homeowners seeking efficient climate control while managing energy expenditures effectively. The reliability and performance of this thermostat have made it a trusted option in residential climate management.