White Rodgers 1F80ST-0471 specifications Applications, Specifications, Index, 0827, Description

Page 1

80 Series Thermostat with

Automatic Heat/Cool Changeover Option

Single Stage or Heat Pump

Installation and Operating Instructions for Model:

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Model

 

Programming Choices

 

 

 

 

1F80ST-0471

5/2 Day

5/1/1 Day

Non-Programmable

1F86ST-0471

 

Non-Programmable

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

 

1F80ST-0471 Thermostat

 

with Spanish Display

 

 

Description

 

 

 

 

 

 

Gas or Oil Heat

Yes

 

Electric Furnace

Yes

 

Heat Pump (No Aux. or Emergency Heat)

Yes

 

Heat Pump (with Aux. or Emergency Heat)

No

 

Systems with up to 3 Stages Heat, 2 Stages Cool

No

 

Heat Only Systems

Yes

 

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

 

Cool Only Systems

Yes

 

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

 

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

 

SPECIFICATIONS

Electrical Rating:

 

Battery Power

mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire

20 to 30 VAC

Terminal Load

1.0 A per terminal, 1.5A maximum all terminals combined

Setpoint Range

45° to 90°F (7° to 32°C)

Differential (Single Stage)

Heat 0.6°F; Cool 1.2°F (adjustable)

Differential (Heat Pump)

Heat 1.2°F; Cool 1.2°F (adjustable)

Operating Ambient

32° to +105°F (0° to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temperature Range

-40° to +150°F (-40° to +65°C)

Dimensions Thermostat

3.4"H x 4.4"W x 1.3"D

 

 

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Index

Page

Installation

2

Wiring Connections

3

Thermostat Quick Reference

3

Installer Confi guration Menu

4

Operating Your Thermostat

6

Programming

6

Troubleshooting

8

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this product may replace a product that contains mercury.

Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container. Refer to www.white-rodgers.com for location to send product containing mercury.

PART NO. 37-6952A

www.white-rodgers.com

0827

Image 1
Contents Applications SpecificationsIndex 0827Installation Displays Guardar Save when Cool SavingsTM is working Wiring ConnectionsThermostat Quick Reference Programming and Configuration ItemsSelect Frio Ahorro Cool Savings and value INSTALLER/CONFIGURATION MenuHeat Cool Heat Pump HP MediumOperating Your Thermostat Planning Your Program Important Energy Saving Factory Pre-ProgramWorksheet for Re-Programming 5/2 Day and 5+1+1 Day Program Reset Operation Troubleshooting