Desa VVMR18, VVMR24 installation manual Gas leak. See Warning statement at

Page 15

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating log set where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Log Set produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most log sets. If noise is excessive, contact qualified ser- vice person

Log Set produces unwanted odors

1.

Log Set burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Open flue to maximum. Stop using odor causing products while log set is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 8)

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 8)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Gas leak. See Warning statement at

2.

Locate and correct all leaks (see Check-

 

 

top of page

 

ing Gas Connections, page 8)

www.desatech.com

901267

15

Image 15
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASFor Use with Log Sets Vented Natural GAS Logs Safety InformationRemote Control Accessories Local Codes Unpacking Optional Product FeaturesON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP Conversion Remote Control Ready Millivolt Safety VALVE/ Pilot KITConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Appliance LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingCheck GAS Type InstallationFlue Opening Specifications Venting Specifications for InstallationInstallation Items Needed Installing Damper ClampConnecting to GAS Supply Pressure Testing Gas Supply Piping SystemInstallation and Gas Connection Hearth KIT Assembly and InstallationOptional GA9000 ON/OFF Safety VALVE/PILOT KIT Assembly Kit AssemblyGas Control Valve with Ther- mocouple and Pilot Propane/LP Gas ConversionTesting Burner for Leaks Installing the Grate and LogsAdding PAN Material Operating Appliance Shutting Off Burner Only pilot stays lit Cleaning and MaintenanceTroubleshooting To Turn OFF GAS To ApplianceClean pilot see Cleaning and Mainte Gas leak. See Warning statement at VVMR18 VVMR24 Illustrated Parts BreakdownKEY Part Number for VVMR18 VVMR24 Description QTY Parts ListKEY Part Number for VMLR18 VMLR24 Description QTY LOG SET Models VMLR18, and VMLR24Accessories Replacement PartsInternational Warranty Information

VVMR18, VVMR24 specifications

Desa VVMR18 and VVMR24 are advanced solutions designed to enhance the efficiency of commercial and industrial heating systems. These models represent a significant leap in technology within the realm of industrial heaters, emphasizing energy efficiency, reliability, and user-friendly operation.

One of the main features of both the VVMR18 and VVMR24 models is their highly efficient heat exchange technology. The design incorporates a compact heat exchanger that maximizes thermal efficiency while minimizing energy waste. This means that users can not only save on operational costs but also reduce their carbon footprint, aligning with global sustainability goals.

The VVMR series utilizes advanced control systems that allow for precise temperature regulation and monitoring. These control systems are equipped with intelligent algorithms that adapt to varying load demands and external conditions, ensuring optimal performance at all times. This feature is particularly beneficial in environments where temperature fluctuations are common, providing stable heating without the need for constant manual adjustment.

In terms of construction, both models boast robust builds, designed to withstand the rigors of industrial use. The use of high-quality materials enhances durability and longevity, reducing maintenance requirements and extending the lifespan of the units. Additionally, their modular design facilitates easy installation and servicing, which is critical in industrial settings where downtime can be costly.

Safety is another critical characteristic of the VVMR18 and VVMR24 models. They come equipped with multiple safety features, including over-temperature protection and pressure relief systems, ensuring reliable operation without compromising on safety. These features are essential in industrial environments where safety regulations are paramount.

In conclusion, the Desa VVMR18 and VVMR24 offer a blend of efficiency, advanced technology, and robust design. Their intelligent control systems, efficient heat exchange technology, and focus on safety make them ideal choices for businesses seeking reliable heating solutions. Investing in these models not only supports operational efficiency but also promotes a commitment to environmental responsibility, making them a wise choice for modern industrial applications.