9.Looking into the opening of the unit under the ember bed, visually locate the light bulbs.

10.Remove the light bulbs by unscrewing them out of the bases turning them coun- terclockwise. You can use one hand to hold the light socket in place, if required.

11.Install the new light bulb(s) by turning the light bulb into the base clockwise. You can use one hand to hold the light socket in place, if required.

12.Reposition the ember bed. If required, gently raise the refractory panels, one at a time, to tuck the ember bed edge underneath them.

13.Reposition the refractory bracket, aligning the refractory in place as required.

14.Reinstall the two (2) screws removed in Step 5.

Figure 9

Figure 10

4W (Max. 5W) Light Bulb

 

FP1618

60W Light Bulbs

FP1739

 

• Maintenance of Motors

Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation.

The motors used on the fan heater and flame blower are pre-lubricated for extended bearing life and require no further lubrication. However, periodic cleaning/vacuum- ing of the appliance around the air intake and exhaust, as well as the fan heater is recommended. For heavy or continuous use, periodic cleaning must be done more frequently. If the heater blows alternating cold and warm air, check the fan for free movement and for debris restricting air flow. If the fan does not move freely, the unit must be turned off and the fan replaced immediately in order to prevent further dam- age to the unit.

• Cleaning

Cleaning of the touchpad label at the bottom front of the unit is to be done only using a soft cloth, slightly dampened in water (if needed, a small amount of dish soap can be added to the water) and dried using a clean, dry soft cloth. Cleaning of the screen diffuser is to be done using only water and a lint free cloth. DO NOT use any abrasive household cleaners as these products will damage the touchpad con- trols and the diffusing screen.

WARNING: Make sure the power is turned OFF

before proceeding.

10009816

11

Image 11
Contents Electric Fireplace Service must be performed by a Qualified service agency00 à 17 h 00 HNE Appelez-nous sans frais Call Toll-FreeÉtats-Unis CanadaTable of Contents Ing unattended Safety InformationElectrical Specifications Installation InstructionsEF22/26/33/36 Fireplace Dimensions Clearance to Combustibles Cabinet InstallationsLocating Your Fireplace Grounding Instructions Electrical ConnectionWA R N I N G T h i s procedure must be conducted by a Direct Hard Wiring Electric FireplaceRemove Front Cover Service InstructionsReplacing the Light Bulbs Glass InformationBefore proceeding Maintenance of MotorsCleaning Electrical Wiring Diagram Fireplace Control Functions Operating InstructionsOverhead Light Flame Speed ControlHeater Control EF33 EF36 Description EF22Year Warranty