Desa Tech CGFB32C, CGFB32NC installation manual Installation Clearances, Clearances see Figure

Page 7

OWNER'S MANUAL

INSTALLATION

nation with unvented Iogsets are intended for use as supplemen-

tal heat. Do not Install them as

I NOTICE: This firebox in combi- your primary heat source. If you have a central heating system,

you may run system's circulat- ing blower while using unrented logs. This will help circulate the heat throughout the house. In the event of a power outage, you can use unrented logs as your pri- mary heat source.

NOTICE: A qua,fled service per- son must install firebox. Follow all local codes.

WARNING: Never install the firebox

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, cloth-

ing, or other flammable objects

are less than 42 Inches from the

front, top, or sidesofthefirebox

Note: Your Comfort Glow firebox is de- signed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your firebox, except where standoff spacers are integrally at- tached. If standoff spacers are attached to your firebox, these spacers can be placed directly against wall or framing materials.

Use the dimensions shown for rough open- ings to create the easiest installation (see Built-In Firebox Installation, page 10).

INSTALLATION

CLEARANCES

_i, WARNING: Maintain the mini-

mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Wall and Ceiling

Clearances (see Figure 6)

A. Clearances from the side of the

fire-

box opening to any combustible wall

Mantel Clearances for

Conventional Installation

Note: Clearances

MINIMUM

CLEARANCE

are the same if

42" Side Wall - 16 "

using optional

Ceiling - 42"

cabinet mantel or

Floor - 0"

builtqn nstallation.

 

16"

Face or

Cabinet

Mantel

12"

__ Corner_

MantelFloor - 0"

Figure 6 - Minimum Clearance to Walland Ceiling

Mantel Clearances for Built-In

Installation

If placing custom mantel above built-in firebox, you must meet minimum clearance between mantel shelf and top of firebox opening.

In high traffic areas

in windy or drafty areas

IL CAUTION: Log heaters In-

 

should not be less

than 16 inches

for a

 

cabinet mantel or

12 inches for

a cor-

 

ner installation.

 

 

B.

Clearances from the top of the firebox

 

Note:

All vertical measurements

are from top of fireplace

opening to bottom of mantel shelf. All measurements

ate in ibches

Mantel Shelf

stalled in this firebox create warm

air currents. These currents move

heat to wall surfaces next to fire-

box. Installing firebox next to vl-

nyl or cloth wall coverings or

operating firebox where impuri-

ties In the air (such as tobacco

smoke, aromatic candles, clean-

Ing fluids, oil or kerosene lamps,

etc.) exist, may discolor walls.

IMPORTANT:Vent-free gas log beaters add moisture to the air.Although this is beneficial, installing firebox in rooms without enough ventilation air may cause mildew to form from too much moisture. SeeAirfor Combus-

tion and Ventilation, pages 4 through 6.

IMPORTANT:Make surethefirebox is level.

If firebox is not level, log set will not work

propedy.

opening to the ceiling should not be less

than 42 inches.

C. When the firebox is installed directly

on carpeting, or other combustible ma-

terial, other than wood flooring, the

firebox should be installed on a metal

or wood panel extending the full width

and depth of the enclosure.

1 •

J

Facing material (above

firebox) may be of

combustible matedal. includingdecorative

mantel orname_lts.

/

Fi_x

Underside of

Mantet

Figure 7 - Minimum Mantel Clearances for Built-In Installation

If your installation does not meet the above minimum clearances, you must:

raise the mantel to an acceptable height,

OR

remove the mantel.

Continued

10_7S

7

Image 7
Contents What to do if YOU Smell GAS Unvented VENT-FREE Universal FireboxAvailable from Safety InformationLocal Codes UnpackingOperation Productproduct FeaturesspecificationsProviding Adequate Ventilation Locating FireboxAIR for Combustion and Ventilation PlanningBtu/Hr Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Determining if You Have a Confined or Unconfined SpaceBuilding AIR for Combustion VentilationVentilation AIR Ventilation Air From InsideInstallation Clearances InstallationClearances see Figure SlowerPower Cord Installing Blower Accessory Model CGFB32C onlyConventional Installation Built-In Installation of Blower AccessoryRear Hole Screw Installing Fireplace ScreenElectrical FlexibleGas Line Outlet HearthBase CGFB32NC CGFB32CParts Under Warranty Technical ServiceAccessories Replacement PartsCGFB32NC Illustrated Parts BreakdownCGFB32NC Part Number Description Parts List FireboxCGFB32C CGFB32C Part Number Description Parts CentralsIndustrial Drive Box Bowling Green, KY Warranty InformationKeep this Warranty International

CGFB32C, CGFB32NC specifications

Desa Tech has established a reputation for delivering innovative heating solutions, and their CGFB32NC and CGFB32C models are no exceptions. These gas-fired blue flame heaters are designed with user convenience, efficiency, and safety in mind, making them ideal options for both indoor and outdoor use.

One of the main features of the CGFB32NC and CGFB32C is their ability to produce consistent and reliable heat output. These models utilize a blue flame technology, which operates by pulling in air from the surrounding environment and heating it before circulating it throughout the space. This process not only enhances energy efficiency but also ensures that the heat distribution is even, providing a comfortable living or working atmosphere.

In terms of specifications, both models are equipped with variable heat settings, allowing users to customize the temperature according to their specific needs. The CGFB32NC and CGFB32C are also capable of heating spaces up to 1,000 square feet, making them suitable for garages, workshops, and large living areas. Their portability adds to their versatility, as they can easily be transported from one location to another.

Safety is paramount in any heating device, and Desa Tech has incorporated multiple safety features into these models. The CGFB32NC and CGFB32C come with an automatic shut-off valve that activates in case of an accidental tip-over or if the heater overheats, ensuring peace of mind for users. Additionally, both models are certified by the relevant safety standards, assuring consumers of their reliability and secure operation.

Another standout characteristic of these heaters is their straightforward operation. They feature an easy-to-use ignition system, allowing for quick startups without the need for complicated setups. Both models are also designed to run quietly, making them suitable for use in environments where noise levels need to be kept to a minimum.

Durability is a key consideration for any heating appliance, and Desa Tech has focused on quality materials and construction in the CGFB32NC and CGFB32C. These heaters are built to withstand the rigors of daily use, ensuring longevity and providing good value for investment.

Overall, the Desa Tech CGFB32NC and CGFB32C gas-fired blue flame heaters stand out for their efficiency, safety, and user-friendly features. Whether it's for home, garage, or workshop heating needs, these models deliver reliable performance and comfort, making them an excellent choice for countless applications.