Empire Comfort Systems VFHS-20/10T-4, VFHS-20R-4 installation instructions 16717-2-0605

Page 23

Figure 3

23.Position blower shield side beneath left flange on burner assembly. Align clearance hole on left flange of burner assembly with screw hole on blower shield side.Attach burner assembly to blower shield side with one (1) 10 x 1/2" screw. (See Figure 3 for not installed or Figure 4 for installed)

24.Remove 8 x 1/4" screw located on left, front of valve cover

Figure 4

on burner assembly. Insert blower shield front adjacent to blower motor and blower shield side. Align clearance hole on blower shield front with left, front screw hole on valve cover. Attach blower shield front to valve cover with 10 x 1/2" screw. (See Figure 3 for not installed or Figure 4 for installed)

25.For fireplace that is not installed, replace burner assembly into interior of fireplace.

26.Place inner casing in front of outer casing.

27.Insert inner casing assembly into outer casing.

16717-2-0605

Page 23

Image 23
Contents Installation Instructions Table of Contents To Death Important Safety InformationDo not Tamper with Pilot Light Safety System Carbon Monoxide Poisoning MAY LeadLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction Specifications Ventilation Air From Outdoors Ventilation Air From Inside BuildingVentilation AIR Checking Manifold Pressure Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyCombustible Material ClearancesInstalling Fireplace in Mantel Figure Installation of Fireplace Into MantelInstallation of Brass Trim Built-In Fireplace Installation BUILT-IN Fireplace InstallationOperation INSTRUCTIONS/FLAME Appearance Placement of Glowing Embers Rock WoolWhat to do if YOU Smell GAS VFHS-20R Lighting InstructionsPilot VFHS-20/10T Lighting InstructionsVFHS-20/10T Pilot Pilot Flame CharacteristicsVFHS-20R Pilot VFHS-20R Main Burner Operation Bedroom Installation VFHS-10T OnlyMain Burner and Thermostat Operation VFHS-20/10TRemote Receiver WiringCheck 750 Millivolt System Operation Appliance shuts off during use. Pilot stays on Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance produces unwanted odorsHOW to Order Repair Parts Parts ListParts View Installing Optional Brick Liner EHL-24-1 Optional Brick Liner Installation InstructionsInstalling Optional Blower VFS-BK Optional Blower Installation Instructions16717-2-0605 Optional Blower Installation Instructions Oiling Blower Motor WiringService Notes Service Notes FAX

VFHS-20R-4, VFHS-20/10T-4 specifications

Empire Comfort Systems has consistently been a frontrunner in the heating industry, and their VFHS-20R-4 and VFHS-20/10T-4 models are prime examples of their commitment to quality and innovation. Designed for efficient and effective heating solutions, these units offer unique features that cater to diverse customer needs.

The VFHS-20R-4 is part of Empire's versatile vent-free heater line, providing an impressive output of 20,000 BTUs. Its design allows for flexible installation options, making it ideal for both residential and commercial applications. One of the standout features of the VFHS-20R-4 is its advanced heating technology, which utilizes radiant heat to warm your space quickly and efficiently. This method not only provides powerful heat but also enhances comfort by distributing warmth evenly.

Furthermore, the VFHS-20R-4 includes a built-in safety pilot system that ensures safe operation. This technology detects any malfunctions and automatically shuts the unit off if necessary, providing peace of mind for users. Additionally, the unit's thermostatic control allows for easy temperature management and helps maintain an energy-efficient environment.

On the other hand, the VFHS-20/10T-4 model is tailored for areas requiring a dual heating approach. This innovative unit combines both vent-free and vented heating options, offering flexibility based on user preferences or regulatory requirements. With a heat output of 20,000 BTUs, it delivers ample warmth while also featuring a compact design that seamlessly fits into various spaces.

Both models boast a sleek and modern aesthetic, ensuring they complement any decor. They are available in multiple finishes, allowing users to choose the one that best suits their style. The ease of installation is another significant advantage, with straightforward instructions enabling users to set up the units with minimal hassle.

In terms of energy efficiency, both the VFHS-20R-4 and VFHS-20/10T-4 are equipped with technologies that minimize energy consumption while maximizing heat output. Their environmentally friendly design helps reduce emissions, making them suitable options for eco-conscious consumers.

In conclusion, the Empire Comfort Systems VFHS-20R-4 and VFHS-20/10T-4 models represent the pinnacle of heating technology. With their efficient features, safety enhancements, and stylish designs, they stand out as excellent choices for anyone seeking reliable and effective heating solutions in their living or working spaces. Whether you need a versatile heating option or a dual-function solution, Empire Comfort Systems delivers with these remarkable models.