CFM Corporation UVDR36C, UVDR42C Install Optional Outside Air Kit, Installation Instructions

Page 9

Install Optional Outside Air Kit

The AKU3 Outside Air Kit can be installed to bring com- bustion air to the heated room air. The air that is drawn into the heated room air from outside the home or un- heated area helps relieve the pressure in the home. The duct termination should be located so it is exposed to an out-of-doors opening at least 100 square inches. If the duct termination must be located in a crawl space or basement, be sure the termination area has 100 square inches of ventilation opening to outside air.

The duct termination must be located so it does not compete for air flow with exhaust fans, gas vent hoods or other air consuming devices or appliances. It must not be obstructed by rafters, insulation materials or other obstructions. The less restrictive the air supply, the better the outside air kits will perform.

It is good practice to protect your hands and eyes during installation by wearing work gloves and safety glasses.

CAUTION: Do not install termination into a garage or other area that could contain flammable liquids or fumes, or into an attic space.

Installation Instructions

Determine the location of the fireplace as described in the fireplace installation manual. Then plan location of the duct termination and the route of the duct run between the fireplace and the duct termination.

Duct run must be limited to a maximum distance of 40’ (12.2m) from the fireplace pipe collar to duct termina- tion. This will provide the least restriction to air flow. No more than four (4) 90° elbows can be used. Duct run may be horizontal, vertical, inclined or any combina- tion of these. (Fig. 12) You are now ready to install the Outside Air Kit.

1.Remove the screws retaining the outside air cover- plate, if provided. (Located on the left side of front open units, on backside of multisided units.) Discard coverplate. (Fig. 13)

2.Secure the inlet collar assembly to the outer casing with four screws (not provided). (Fig. 14)

3.Slide the duct over the collar and attach the duct to the collar using the plastic tie straps or three (3) screws (screws not provided). Continue attaching the ducting together using three (3) screws at each joint until you have installed sufficient duct to arrive at your duct termination locations.

4.At the termination end, install the duct termination. This should be installed from the outside of the home. Cut a hole in the desired location approxi- mately 4¹⁄₂” (114mm) in diameter, caulk around the hole, and slide the termination through the opening from outside the home. The termination/rain cap

UVDR Series Unvented Gas Fireplaces

should be caulked around its perimeter to assure a tight seal. The rain cap opening should be positioned downward. (Fig. 15)

The Outside Air Kit is now installed and ready for use.

Soffit Termination

 

Attic

Duct

Ceiling

Termination

 

40’ Max.

Duct Run

Duct

Exterior Wall Termination

Exterior Wall

40’ Max. Duct Run

Rain Cap

Duct Termination

Duct

 

FP1060

Fig. 12 Typical outside air installations.

Cover Plate

KT143

Fig. 13 Remove outside air cover plate and discard, retain screws.

20007469

9

Image 9
Contents UVDR42C Table of Contents UVDR36/42C specifications and framing dimensions Fireplace DimensionsGas Line Locating the FireplaceDrafts Fireplace ClearancesInstall the Firebox Installing the FireboxFraming the Firebox Level the FireboxGas Piping and Connection Optional Procedure For Cold Climate Instal- lationsInsulation of the Fireplace Enclosure Insulate to Seal Under the FireplaceElectrical Services Pre-Wiring of Junction BoxFinishing the Fireplace Hearth ExtensionBlower Installation UVDR36C Blower InstallationUVDR42C Blower Installation Installation Instructions Install Optional Outside Air KitOperating Precautions and Instructions Description UVDR36/42C Series Unvented FireplacesServicing AccessoriesUvdr Series Unvented Gas Fireplaces Uvdr Series Unvented Gas Fireplaces Limited Lifetime Warranty CFM Corporation

UVDR36C, UVDR42C specifications

CFM Corporation is a leading name in the world of efficient ventilation and air quality management, and its UVDR series, specifically the UVDR36C and UVDR42C models, stands out for their innovative features and advanced technologies. Designed for residential and commercial applications, these units are engineered to enhance air quality while ensuring energy efficiency.

The UVDR36C model is equipped with a powerful 36-inch UV-C air purifier that helps to eliminate airborne pathogens, viruses, and bacteria. This model utilizes ultraviolet light technology, which is proven to disinfect and purify air more effectively than traditional methods. Likewise, the UVDR42C offers a broader 42-inch purification coverage, catering to larger spaces or more demanding air quality needs.

Both models feature a robust filtration system that combines high-efficiency particulate air (HEPA) filters and activated carbon, trapping harmful particulates while neutralizing odors. The HEPA filters help to capture dust, pollen, pet dander, and other allergens, significantly improving indoor air quality. The activated carbon works to remove volatile organic compounds (VOCs) and other undesirable smells, promoting a fresher environment.

One of the standout characteristics of the UVDR series is their smart technology integration. These models are equipped with real-time air quality monitoring sensors, which adjust the purification levels based on the detected pollutants. This intelligent feature not only maximizes efficiency but also ensures that the air remains clean without unnecessary energy consumption.

Energy efficiency is a hallmark of the UVDR series. Designed to minimize power usage while maintaining optimal performance, both models operate quietly, making them ideal for homes, offices, and various commercial environments. This energy-efficient operation is complemented by an easy-to-use interface and user-friendly controls, allowing for seamless adjustments and monitoring.

The construction quality of both the UVDR36C and UVDR42C is robust, ensuring durability and longevity. With modern aesthetics, they fit seamlessly into any interior decor. Furthermore, maintenance is straightforward, with easy access to filters for replacement, making upkeep hassle-free.

Overall, the CFM Corporation UVDR36C and UVDR42C models represent a compelling choice for those seeking advanced air purification solutions. With their unique features, innovative technologies, and commitment to energy efficiency, CFM continues to set the standard in air quality management.