Enviro EG40 BV owner manual Specifications, EG40 Exterior Dimensions

Page 5
���
���� ���
Figure 2: Clearances to combustibles.

Specifications

WARNING:

Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

DIMENSIONS:

��

���� ���

���� ���

���

��

���� ���

���� ���

���

���� ���

Figure 1: EG40 Exterior Dimensions.

CLEARANCES TO COMBUSTIBLES:

A. Sidewall to unit

12 inches

(30.5 cm)

 

 

B. Backwall to unit

4 inches

(10.2 cm)

��

 

C. Corner to unit

2 inches

(5.1 cm)

��

���� ���

D. Combustibles to unit top

36 inches (91.4 cm)

��� ���

 

 

E. Floor to unit

0 inches

 

 

 

F. Alcove maximum depth:

48 inches (121.9 cm)

 

 

Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building; e.g. cutting a wall or ceiling joist.

Check stove and flue system clearance requirements.

Locate the stove where it can be accessed by a gas supply line.

Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation and comfort.

As the stove is equipped with a convection fan, ensure that an electrical outlet is within 6 feet. (1.8 m) of the stove.

The flow of combustion and ventilation air must not be obstructed.

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.

PREPARATION FOR INSTALLATION:

Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible.

Before beginning, carefully check the glass door and the log set

5

Image 5
Contents EG40 BV General Safety PrecautionsFor Your Safety Table of Contents Vented GAS Fireplace Heater EG40 BV NG/LPG Codes And ApprovalsEG40 Exterior Dimensions SpecificationsQualified Installers only Initial InstallationHeight of Vertical Termination Straight vertical installation Wiring of a Thermostat Turn the unit off and remove the log set 50% turn down HI-LOW Regulator To Test Valve Pressures GAS Line ConnectionLog Placement Secondary InstallationLog Placement with Embers What to do if YOU Smell GAS Operating InstructionsCleaning the Inside of the Firebox Routine Maintenance and ServiceCleaning Plated Surfaces Opening the DoorProblem Possible Cause Solution Trouble ShootingParts List Reference Part Description Part Number Parts Diagram Chassis Parts Diagram Gas Tray & DoorTo the Distributor WarrantyInstallation Data Sheet