Dimensions | H200 | H300 |
A | 27" | |
B | ||
B (short legs) | ||
C | ||
D | 26" | |
E | 21" | 24" |
F | 16" | |
G | 7" | |
H | ||
H (short legs) | ||
I | 15" | 15" |
J* | ||
J* (short legs) | 21" |
* to center line if rear vented.
Specifications | H200 | H300 |
EPA Certified | Yes | Yes |
Optimum Efficiency | 74% | 74% |
Emissions (grams/hr) | 3.9 | 4.1 |
Maximum BTU* | 38,800 | 45,500 |
Typical Sq. Ft. Heated | ||
Maximum Log Size | 16" | 18" |
Firebox Size | 1.34 cu. ft. | 1.71 cu. ft. |
Flue size | 6" | 6" |
Burn time (typical)* | up to 6 hrs | up to 8 hrs. |
Shipping Weight | 425 lb | 500 lb |
*Length of burn time and BTU range depend on type of wood, climate condi- tions and installation.
B | E |
D | * |
| |
A |
|
C
F
C F
Minimum Clearance To Combustibles | A | B | C | D | E | F | |
H300 | Residential Installation "C" Vent | 17" | 15" | 13" | 30" | 15" | 19" |
| Residential Close Clearance | 15" | 10" | 9" | 28" | 10" | 15" |
| Mobile Home Close Clearance | 15" | 10" | 9" | 28" | 10" | 15" |
H200 | Residential Installation "C" Vent | 17" | 15" | 13" | 29" | ||
| Residential Close Clearance | 15" | 10" | 9" | 27" | ||
| Mobile Home Close Clearance | 15" | 10" | 9" | 27" |
Note: In Canada floor protection must extend 18" to the front and 8" to the sides and back. With side load door floor protection must extend 18" to the side. In US same as above except floor protection extends 6" to sides and back.
*Minimum clearance with side load door is 18" to side wall. Refer to dimension (B) for clearance without side load door.
wood inserts
C
A
B
D
E
Dimensions | HI200 | HI300 | HI300 oversize |
A | 30" | ||
B | |||
C | |||
D | 40" | ||
E | |||
F | |||
G | |||
G (offset adaptor) | |||
H |
Specifications | ||
EPA Certified | Yes | Yes |
Optimum Efficiency | 73.8% | 77% |
Emissions (grams/hour) | 3.0 | 3.8 |
Maximum BTU* | 55,000 | 75,000 |
Typical Sq. Ft. Heated | ||
Maximum Log Size | 18" | 18" |
Firebox Size | 1.4 cu.ft. | 2.3 cu.ft. |
Flue size | 6" | 6" |
Burn time (typical)* | up to 8 hrs. | up to 8 hrs. |
Shipping Weight | 258 lb. | 500 lb. |
*Length of burn time and BTU range depend on type of wood, climate conditions and installation.
G
H
F
B | C |
A | D |
| E |
F | G |
|
Minimum Fireplace Opening | HI200 | HI300 |
Width (front) | 23" | 25" |
Height | ||
Depth (w/ standard flue adaptor) | ||
(w/ offset flue adaptor) |
|
Masonry & Factory Built Fireplace Clearances
The minimum required clearances to combustible materials when installed into a masonry fireplace are:
| Adjacent Side Wall | Mantel | Top Facing | Side Facing (to | Min. Hearth | Min. Hearth | Min Hearth Side |
| (to side) | (to top) | (to top)*** | side)*** | Extension* | Elevation* | Extension** |
| A | B | C | D | E | F | G |
HI200 | 15" | 20" | 14" | 18"CA/16"US | 8"/6" US | ||
HI300 | 11" | 20" | 12" | 8" | 18"CA/16"US | 0.5" | 8" |
* Note: If the hearth extension is flush with the floor (item F) it must extend 19.5 in. in front of the body face (item E).
** Note: Hearth extension width (G) is measured from edge of fuel door to side of hearth.13
*** up to