Weil-McLain Boiler installation manual Hazard definitions, Selection data

Page 3

GAS-FIRED WATER BOILER Installation Manual — Multiple-boiler Systems

Hazard definitions

The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product.

Indicates presence of hazards that will cause severe personal injury, death or substantial property damage.

Indicates presence of hazards that can cause severe personal injury, death or substantial property damage.

Indicates presence of hazards that will or can cause minor personal injury or property damage.

Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury or property damage.

Selection data

Controls

Weil-McLain offers an excellent selection of boiler sequencing controls. Refer to individual manuals for details.

Domestic hot water

Refer to Weil-McLain Piping Guides and PLUS Water Heater Manual and Ultra PLUS Supplement for suggested piping diagrams.

Venting and combustion air

Ultra boilers must be vented individually. Combustion air must be piped to the boiler as well, but may be manifolded as shown on page 13. Follow Weil-McLain Ultra Boiler Venting Supplement and Boiler Manual plus information in this manual. Failure to comply will result in severe personal injury or death.

Additional considerations

1.Review the Ultra Boiler Manual and applicable supplements prior to designing and installing multiple- Ultra-boiler jobs.

2.Ultra boilers are design-certified for installation on combustible flooring (not carpet).

3.Ultra boilers are tested for 30 P.S.I. working pressure (higher pressure not available).

4.For systems requiring greater than 30 P.S.I. relief valve setting, install a heat exchanger to isolate the boilers from the main system. See page 12 for suggested piping.

5.Maximum operating temperature of each boiler is 190°F.

This manual provides general guidelines for piping and installation. Your installation must comply with all applicable local codes.

When using isolation valves on each boiler, some codes may require providing a low water control and additional limit for each boiler. If desired, consult the codes to determine if exclusion of the individual boiler isolation valves may allow the use of a single water level control and additional limit for the entire multiple boiler system.

Part number 550-101-232/0703

3

Image 3
Contents Installation Manual Contents Selection data Hazard definitionsDOE Ratings and engineering dataRatings and engineering data Water header pipingDimensional data DimensionsPlacement and mounting information Placement, generalWall mounting Easy-FitPiping Easy-Fit Piping installationFlow/check valve each boiler System air eliminator Easy-FitPiping Check valve to prevent heat migration in heating system Use isolation heat exchanger for Combustion air piping Combustion air & vent piping installationVent piping Combustion air manifoldsGas piping Connecting gas supply pipingCommon gas piping installation Water treatment WiringAdditional instructions Air for boiler room ventilation

Boiler specifications

Weil-McLain is a renowned manufacturer of heating systems, particularly known for its high-efficiency boilers designed for residential, commercial, and industrial applications. With a legacy spanning over a century, Weil-McLain has built a reputation for durability, performance, and energy efficiency in the heating industry.

One of the primary features that sets Weil-McLain boilers apart is their diverse range of products. They offer various types of boilers including cast iron, stainless steel, and high-efficiency condensing models. This versatility allows homeowners and businesses to select the best system suited to their specific heating needs.

Weil-McLain boilers are equipped with innovative technologies that enhance efficiency and user experience. Many of their models feature advanced control systems which enable precise temperature management. This leads to optimal energy usage and ensures comfortable indoor environments while reducing greenhouse gas emissions. Moreover, their smart technology options include integration with smart home systems, allowing users to gain remote access and control over their heating systems via mobile devices.

Energy efficiency is a primary characteristic of Weil-McLain boilers, with many models achieving Energy Star certification. The high-efficiency condensing boilers utilize advanced heat exchanger technology to maximize heat extraction, enabling them to achieve impressive annual fuel utilization efficiency (AFUE) ratings. This not only conserves energy but also contributes to reduced utility bills for consumers.

In addition to efficiency, durability is a hallmark of Weil-McLain products. Their cast iron boilers are known for their robust construction, which provides long-lasting performance and reliability. This durability is further supported by comprehensive warranties that offer peace of mind to customers.

Ease of installation and maintenance is another advantage of Weil-McLain boilers. Many units are designed with user-friendly interfaces and accessible components, making them convenient for professional installers and service technicians. This can lead to reduced labor costs and downtime for homeowners and business operators.

Weil-McLain also places an emphasis on customer support and service, with a network of experienced professionals ready to assist with installation, maintenance, and troubleshooting. Their commitment to quality and service has solidified their position as a trusted leader in the heating industry.

In conclusion, Weil-McLain boilers offer a blend of advanced technology, energy efficiency, durability, and user-friendly features. They continue to meet the evolving needs of customers, making them a preferred choice for reliable heating solutions in various settings.