Weil-McLain 88 Series specifications

Page 3

Port openings must be of captured seal design – a machined groove assures uniform compression of the sealing ring and protects the seal from contaminants. Elastomer sealing rings are to be used to provide permanent water-tight seal between sections. Unlike cast iron or steel push nipples, the elasticity of the seals fills any gaps caused by misalignment or expansion or contraction.

Provided with flexible refractory blankets attached to back and floor of combustion chamber.

Shipped with insulated heavy gauge steel jacket(s) with durable powdered paint enamel finish. Jacket designed to be installed after connecting supply and return piping.

D.Tankless heaters or indirect water heaters

Provide ( ) internal tankless water heater(s) inserted into the left hand side of the tankless intermediate (TI) section in the opening provided. Allow 34” minimum clearance on left side of boiler for cleaning and servicing. Tankless openings must be on same side as the flue passage cleanout plates to minimize space requirements.

E.Boiler foundation(s):

Installer to construct needed support and level concrete foundation(s) where boiler room floor is uneven or will not support the weight of the boiler(s).

F.Boiler trim:

1.All electrical components to be of high quality and bear the U.L. label.

a)Water boiler(s) controls furnished:

1)Combination low temperature limit (operating) and high temperature limit control.

2)Low temperature limit set according to system design. High temperature limit set at least 20°F higher than the low limit (240°F is the maximum allowable water temperature).

3)Combination pressure-temperature gauge with dial clearly marked and easy to read.

4)ASME certified pressure relief valve, set to relieve at 30 PSIG. Optional relief valves available up to and including maximum allowable pressure. Side outlet discharge type; contractor to pipe outlet to floor drain or near floor, avoiding any area where freezing could occur.

b)Steam boiler(s) standard controls furnished:

1)Low pressuretrol (operating) and high pressuretrol set at maximum pressure as a safety control.

2)Steam pressure gauge with dial clearly marked and easy to read.

3)Gauge cock water set with gauge glass, guards and aluminum water level plate.

4)ASME certified pressure relief valve, set to relieve at 15 PSIG. Side outlet discharge type; contractor to pipe outlet to floor drain or near floor, avoiding any area where freezing could occur.

c)Low water cut-off for water or steam boiler(s):

1)Boiler(s) to be furnished with U.L. labeled low water cut-off with ASME working pressure rating equal to the ASME rating of the relief valve.

2)Do not use quick-connect fittings on boiler(s).

3)Install cut-off according to manufacturer’s instructions.

3

Image 3
Contents General Requirements Series BoilerII. Product Page III. Burners construction, features and requirements

88 Series specifications

Weil-McLain’s 88 Series is a prominent line of cast iron boilers designed to provide reliable heating solutions for both residential and commercial applications. Known for its durability and efficiency, the 88 Series has become a preferred choice among HVAC professionals. One of the main features of the Weil-McLain 88 Series is its robust construction. Crafted from high-quality cast iron, these boilers are built to withstand the test of time, offering longevity and resilience against the demands of heating systems. The cast iron construction also contributes to excellent heat retention, ensuring optimal efficiency in energy usage.

In terms of technologies, the 88 Series integrates an advanced ignition system that enhances safety and reliability. This reliable ignition mechanism reduces the risks associated with gas-fired boilers while ensuring smooth operation. Moreover, the 88 Series is designed with an intuitive control system that allows for easy adjustments to temperature settings and other operational parameters. This level of user-friendly control helps homeowners and facility managers maintain their desired comfort levels effortlessly.

Another defining characteristic of the Weil-McLain 88 Series is its efficiency rating. With levels reaching up to 84% AFUE (Annual Fuel Utilization Efficiency), the boilers are designed to maximize energy use, translating to cost savings on utility bills. The series also features a wide range of sizes and outputs, making it suitable for various applications, from small homes to larger commercial buildings.

The installation of the 88 Series is made easier with its lightweight design, allowing for straightforward handling and setup. Furthermore, the boilers include a standard flue outlet, ensuring compatibility with existing venting systems, which minimizes additional installation costs.

Maintenance of the 88 Series is also made simple with its clean-out ports, allowing technicians easy access for routine checks and service. This ease of maintenance contributes to the overall reliability and efficiency of the heating system, ensuring it operates optimally throughout its lifespan.

In summary, the Weil-McLain 88 Series stands out for its combination of durable construction, advanced technology, high efficiency, and ease of installation and maintenance. Whether for residential or commercial heating needs, the 88 Series represents a solid choice for those seeking reliability and performance in their heating systems.