Vector VEC192 user manual Troubleshooting, Specifications, Battery Replacement, Battery Disposal

Page 6

WARNING

To reduce the risk of electric shock, replace bulbs with 12 volt H7 100 watt only.

Battery Replacement

1.Release the battery compartment cover locks on either side of the unit and remove the cover.

2.Pull out the battery.

3.Disconnect the terminals and replace the battery with the same type listed in the Specifications section of this manual.

4.Replace the battery compartment cover and engage the locks.

5.Turn one of the Spotlight’s ON/OFF switches to the ON position to ensure proper operation of Spotlight.

Battery Disposal

Non-spillable sealed lead-acid battery — This battery is fully recyclable and should be accepted at any location that accepts common automotive starter batteries. Examples of places that accept these batteries are: county or municipal recycling drop-off centers, scrap metal dealers, and retailers who sell automotive replacement lead acid starter batteries. For more information on recycling this recycling this battery, call toll-free (877) 288-7722.

WARNING

Before disposing of the battery, protect exposed terminals with heavy-duty tape to prevent shorting. (Shorting can result in injury or fire.)

Do not expose battery to fire or intense heat as it may explode.

DC Plug Fuse Replacement

The fuse in the DC plug protects the charging circuit of the DC recharge adapter. If the AC recharger operates but the DC charging adapter does not, then the fuse may be opened.

To replace the fuse:

1.Unscrew the end cap of the DC plug (counterclockwise).

2.Remove spring center contact and fuse.

3.Check fuse with a continuity checker.

4.If blown, locate replacement fuse with same type and rating.

5.Replace the fuse, spring, contact and end cap.

6.Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.

7.Check for proper operation of DC charging adapter.

TROUBLESHOOTING

1.The 120 volt AC charging/recharging method will not work while the Spotlight is in use.

2.If the unit does not operate, the battery may be completely discharged. Charge the unit using the AC adapter following the directions in the manual.

3.If you suspect a bulb is blown, check the bulb filament. If filament is coiled and unbroken, the bulb is not blown. If filament is blown, replace bulb.

4.If you suspect the main fuse is blown, check it and, if necessary, replace with a new 20 amp spade fuse.

SPECIFICATIONS

Spotlight Bulbs:

Two 12 volt, H7 series, 100 watt bulbs

Battery:

Maintenance-free, sealed lead acid, 12 volt, 7.0 Ah

AC Adapter:

500mA, 12 volt

Operating Voltage:

12 volts DC

6

7

Image 6
Contents SportSpot Important Safety Instructions Table of Contents Volt AC Charging/Recharging Charging the BatteryChecking Battery Charge Status Volt DC Charging/RechargingCare and Maintenance Operating InstructionsBattery Replacement TroubleshootingSpecifications Battery Disposal