SAFETY TIPS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70- 1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

5. Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support.

9. (Mounting must support at least 35 lbs.)

10. Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

11. Attach the mounting bracket using only the hardware supplied with the outlet box.

12. To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

13. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

14. NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip- ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

15. Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

 

 

Phillips Screwdriver

TOOLS REQUIRED

Pliers

 

1

Wire Cutters

 

2

 

 

 

Unpack and inspect fan carefully to

 

Before you begin installing the fan, Switch power off

 

 

 

 

 

 

to prevent power from being switched on accidentally.

 

 

be certain all contents are included.

 

at Service panel and lock service disconnecting means

 

 

 

When the service disconnecting means cannot be

 

 

(See exploded view parts lists.)

 

locked, securely fasten a prominent warning device,

 

 

 

such as a tag, to the service panel.

 

 

4

 

 

5

 

 

 

 

 

 

 

 

Install mounting brackets to outlet

 

Feed motor lead wires through downrod/canopy

 

 

 

 

 

 

assembly and insert downrod into motor yoke.

 

 

box in ceiling using the screws pro-

 

Next, insert clevis pin through yoke and down-

 

 

vided with the outlet box and wash-

 

rod and secure with cotter pin. (see Inset)

 

 

 

Tighen both yoke set screws to further secure

 

 

ers.

 

downrod.

 

Step Ladder

3

Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or per- sonal injury, mount to outlet box or supporting system acceptable for fan support.

(Mounting must support at least 35 lbs.)

6

Carefully lift fan assembly onto mounting bracket. Rotate fan so that the notch on the ball engages the ridge in the mount- ing bracket. This will allow hands-free wiring.

Image 2
Contents Owner’s Manual Install mounting brackets to outlet Be certain all contents are includedSee exploded view parts lists Box in ceiling using the screws proThrough the mounting bracket While the fan assembly is still onGround thread the safety cable Screws previously removed After attaching blade reinstallSwitch housing using the three Trouble Suggested Remedy If fan does not start If fan sounds noisy If fan wobbles

5DS44 Series specifications

The Monte Carlo Fan Company has established itself as a leader in the ceiling fan industry, and their 5DS44 Series is no exception. This series exemplifies a blend of modern design, advanced technology, and superior performance, making it an excellent addition to various living spaces.

One of the most notable features of the 5DS44 Series is its sleek and contemporary design. Available in various finishes such as matte black, polished nickel, and white, the fans seamlessly fit into a range of interior aesthetics. The minimalist style ensures that they complement both traditional and modern decor, adding a touch of sophistication to any room.

The 5DS44 Series is equipped with an efficient DC motor, which not only enhances energy efficiency but also reduces noise levels significantly. This technology allows the fan to operate quietly, making it suitable for bedrooms, living rooms, or any space where tranquility is essential. The DC motor also contributes to lower energy consumption, making it an environmentally friendly choice that can help reduce electric bills.

In terms of performance, the 5DS44 Series boasts impressive airflow capabilities. With its 44-inch blade span, the fan is designed to generate optimal airflow, ensuring comfortable conditions in medium to large-sized rooms. The fan's aerodynamic blades are engineered for maximum efficiency, providing a refreshing breeze even at low speed settings.

Another key characteristic of the 5DS44 Series is its versatility in operation. The fans typically come with multiple speed settings, allowing users to customize their comfort level according to individual preferences and seasonal needs. Additionally, many models in this series offer remote control functionality, providing convenient access to speed adjustments and light settings from anywhere in the room.

Installation is easy, as the Monte Carlo Fan Company designs its products with a user-friendly approach. The 5DS44 Series often includes a user-friendly mounting system that simplifies the installation process for both professionals and DIY enthusiasts.

In conclusion, the Monte Carlo Fan Company 5DS44 Series combines aesthetic appeal with cutting-edge technology and user-centric features. The combination of energy-efficient performance, striking design, and quiet operation makes this series an excellent choice for anyone looking to enhance the comfort and style of their home. Whether you are refreshing a modern space or adding a contemporary touch to a classic interior, the 5DS44 Series is sure to impress.