Monte Carlo Fan Company 5RH52 installation instructions Such as a tag, to the service panel

Page 2

SAFETY TIPS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

1.Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes ANSI/NFPA 70-1999),

2.including fire-rated construction.

3.Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-

4.ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,

5.such as a tag, to the service panel.

6.Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

7.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7

8.feet from the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support.

9.(Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating

10.blades.

11.Attach the mounting bracket using only the hardware supplied with the outlet box.

12.To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heat- ing equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA),

13.and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

 

 

Phillips Screwdriver

Wire Cutters

Pliers

 

1

 

 

2

 

 

 

 

 

 

 

 

Before you begin installing the fan, Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

power off at Service panel and lock service dis-

 

Before installing this fan make sure the outlet box is

 

connecting means to prevent power from being

 

properly installed to the house structure. To reduce

 

switched on accidentally. When the service dis-

 

the risk of fire, electric shock, or personal injury,

 

connecting means cannot be locked, securely

 

mount to outlet box or supporting system acceptable

 

fasten a prominent warning device, such as a

 

for fan support. (Mounting must support at least 35

 

tag, to the service panel.

 

lbs.)

 

4

 

yoke

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3Step Ladder

Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securley fas- tened by at least two points to a structural ceil- ing member ( a loose box will cause the fan to wabble). Use only the screws provided with the outlet box.

6

Loosen the 2 set screws till you can not feel them on inside of yoke.

Place canopy on downrod. (as shown)

Thead leadwires and safety cable through downrod. (as shown)

Image 2
Contents OWNER’S Manual Such as a tag, to the service panel Thead leadwires and safety cable through downrod. as shownBlack Blue White Ground GreenPage Install decorative finial nut to glass to secure in place Rouble Hooting