Minolta W091CA TSG0 Adjusting the Air Flow Direction, How to Attach Drain Pan Some Models

Page 12

HowtoAttach DrainPan(SomeModels)

The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the air) is drained to the outside.

In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water removed from the air may cause some water to collect. To remove this excess water you can install the drain pan as

detailed below.

CABINET

 

1.Take the drain pan which is located in the air discharge.

2.Remove the hole rubber from the base-pan (for some models).

3.Install the drain pan to the right corner of the cabinet with 4 (or 2) screws.

4.Connect the drain hose to the outlet located at the bottom of the drain pan.You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied).

DRAIN

PAN

SCREW

DRAIN HOSE

HowtoConnecta DrainHose

A drain hole is provided at the rear of the air conditioner unit.

Select a drain method according to the following.

1.Remove the hole rubber from the base-pan. (for some models)

2.Connect a drain hose to the drain pipe as shown in Fig. 1.

3.Or connect a pipe elbow to the drain pipe, then connect a drain hose to the pipe elbow as shown in Fig. 2.

Fig. 1

DRAIN PIPE

DRAIN HOSE

Fig. 2

DRAIN PIPE

DRAIN ELBOW

DRAIN HOSE

Operating Instructions

Adjusting the Air Flow Direction

TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET.

OutdoorCoils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through a dealer.

12

Image 12
Contents Room Air Conditioner Table of Contents English Operation Do not allow water to run Thinner Location and Function of Controls Operation Controls Heater LampRemote Control Operation How to Insert the BatteriesVentilation Air DirectionAdjusting the Air Flow Direction How to Attach Drain Pan Some ModelsOutdoor Coils Care and Maintenance Air Filter CleaningHardware Installation FeaturesInstallation Hardware Select the Best Location Remove the Air Conditioner From the CaseInstall the Air Conditioner in the Case Use the Reversible Inlet GrilleCommon Problems and Solutions Nota EspañolNo. MFL57207002