Middleby Marshall KIT P/N 36939 manual Current & Obsolete Thermocouple Comparison

Page 6

5.Check to be sure the oven’s thermocouple is the latest version flange mount style verses the obsolete version. See Figure 4 below.

Flange

Current Thermocouple

PS360 (6.00”)

PS200 (13.38”)

Clip

Obsolete Thermocouple

Figure 4 - Current & Obsolete

Thermocouple Comparison.

cable

The obsolete thermocouple is not compatible with the latest temperature controller, p/n 36056, and must be replaced with the latest thermocouple, kit p/n 33984 (300 Series ovens), and kit p/n 33985 (200 Series ovens). The obsolete thermocouples leads are grounded to the protective sheathing which causes an error signal with the latest controller’s thermocouple circuit.

6.After becoming familiar with the various electrical connections pertaining to the specific model oven and its temperature controller, refer to table 2 for specific wiring instructions for all wires and any jumpers to be reinstalled.

NOTES:

________________________________________________________________________________

________________________________________________________________________________

________________________________________________________________________________

________________________________________________________________________________

________________________________________________________________________________

________________________________________________________________________________

________________________________________________________________________________

5

Image 6
Contents 500 F Installation Instructions Disconnecting Existing Wires / Mechanical Installation Temperature Controller or Damage to the Control will Result Electrical ConnectionsAnalog to Digital Terminal Cross Reference Current & Obsolete Thermocouple Comparison Wiring Configurations Oven Model Number Related Figure Hh h Programming O F 250 Diagnostic Error Messages RPLC