Installation Instructions
Maretron TP-AAP-1 TMP100 Ambient Air Temperature Probe
NOTE: The
Instructions
Please follow these instructions to connect the
1.Using a cable clamp or other means, secure the
2.The
3.Connect the red wire to the appropriate Tx+ terminal on the TMP100 as shown in Figure 1 below.
4.Use a DSM250 (firmware 1.3.8 or greater) or other Maretron display product capable of configuring the TMP100 to configure the “Channel #x Source” to the type of temperature you are measuring.
5.Use a DSM250 (firmware 1.3.8 or greater) or other Maretron display product capable of configuring the TMP100 to configure the “Channel #x Instance” to a number that is unique across the network for the source you have selected. In other words, if you are measuring Freezer Temperature, there may be only one channel on the network that measures Freezer Temperature that has an instance number of 0. Number further Freezer Temperature channels as instance #1, #2, and so on.
6.If desired, use DSM250 (firmware 1.3.8 or greater) or other Maretron display product capable of configuring the TMP100 to configure the “Channel #x Label” to a text string that allows you to identify the particular temperature that is being measured by this probe. For example, if you have two freezers, you may wish to label one of them “Port Freezer” and the other “Starboard Freezer”.
7.Using a Maretron DSM250 or Maretron N2KView, show the temperature with the source and instance you have selected and verify that you see a valid temperature on the display.
|
|
|
|
|
|
|
| Red Black | |
|
|
|
|
|
|
|
|
| TMP100 Screw Terminals |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 11 12 |
T0+ | T0- | T1+ | T1- T2+ | T2- | T3+ | T3- | T4+ | T4- T5+ T5- |
Figure 1 – Wiring Diagram
Maretron, LLP
9014 N. 23rd Ave #10
Phoenix, AZ 85021
Telephone: (+1)
Copyright © 2011 Maretron, LLP All Rights Reserved | P/N: M002103 Rev.1.1 1/11 |