F36 BLOWER KIT

An Optional Blower Kit is available for the 2847 Wondercoal automatic coal

RULES FOR SAFE INSTALLATION AND OPERATION

Read these rules and the instructions carefully.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

burning circulator heater. If this kit is not available where you have purchased this Wondercoal heater, you can purchase the F36 Blower Kit directly from the factory. To order contact the United States Stove Company at the address and telephone number given on the back page.

22

1.Check local codes. The installation must comply with their rulings. Do not install this heater in a mobile home or trailer.

2.Always connect this heater to a chimney or vent to the outside. Never vent to another room or inside a building.

3.Do not connect a COAL burning heater to an aluminum Type B gas vent. This is not safe and is prohibited by all codes. This heater requires connection to approved chimneys: Either a factory built 6" UL 103HT or a lined and approved and recently in- spected and cleaned masonry chimney with a 6" flue, preferably round. A larger masonry flue may be used, so long as the flue-section diameter is not greater than 50 sq. in.

The chimney portion (whether factory-built or masonry) must be tall enough to provide sufficient draft and safe exit of smoke and combustion products. Please refer to Page 5.

4.Be sure that your Chimney is safely con- structed and in good repair. Have the chim- ney inspected by the Fire Department or a qualified inspector (such as a Chimney sweep). Your insurance company may be able to recommend a qualified inspector.

5.Inspect chimney connector and chimney twice monthly during the heating season for any deposit of creosote or soot which must be removed.

6.Provide air for combustion from outside the house into the room where the heater is located. If the intake is not in the same room, air must have free access to the room.

7.CAST IRON PARTS MUST BE "SEA- SONED" TO AVOID CRACKING. BUILD ONLY SMALL FIRES ON FIRST USE.

8.To prevent injury, do not allow anyone to use this heater who is unfamiliar with the correct operation of the heater. Do not allow children to use or in any way operate this heater.

CAUTION: DO NOT TOUCH THE HEATER UNTIL IT HAS COOLED. ALWAYS WEAR GLOVES WHEN REFUELING THIS UNIT OR WORKING WITH METAL CABINET PARTS.

9.For further information on using your heater safely, obtain a copy of the National Fire Protection Association (NFPA) publica- tion "Using Coal and Wood Stoves Safely" NFPA No. HS-10-1978. The address of the NFPA is Battery March Park, Quincy, MA. 02269.

10.Keep the ash pit section free of excess ashes. Do not allow ashes to stack higher than the sides of the ash pan.*

11.DISPOSAL OF ASHES- Ashes should be placed in a metal container with a tight fitting lid. Keep the closed container on a non-combustible floor or on the ground, well away from all combustible materials. Keep the ashes in the closed container until all cinders have thoroughly cooled. The ashes may be buried in the ground or used as fertilizer.

12.CAUTION: The special paints used on your heater may give off some smoke while they are curing during first few fires. Build small fires at first. The metal used in construction of the heater has a light coat- ing of oil. This could give off smoke and/or odors when heater is used for the first couple of times. This should disappear after a short period. Once this burn-off has occurred, it should not reoccur.

13.CARING FOR PAINTED PARTS- This heater has a painted outside jacket, which is durable but will not stand rough handling or abuse. When installing your heater, use care in handling. Clean with soap and warm water when heater is not hot. DO NOT use any harsh chemicals (acids or caustics) or scouring powder, as these wear and dull the finish.

14.KEEP THE FEED DOOR, ASH DOOR AND CABINET DOOR CLOSED AT ALL TIMES EXCEPT WHILE TENDING THE HEATER. DO NOT OVERFIRE THE HEATER. THIS WILL HAPPEN IF THE FEED DOOR, OR PARTICULARLY THE ASH DOOR, IS LEFT OPEN DURING OPERATION. UNDER EXTREME CON- DITIONS THIS CAN PRODUCE DAN- GEROUS RESULTS. AS A MINIMUM, IT WILL ALLOW THE PAINT TO DISCOLOR.

15.Use coal only. DO NOT USE the coal bricks that are manufactured from coal dust and a wax-type binder.

*Never allow ashes to contact the grate(s).

3

Image 3
Contents Safety Notice HOW to Order Repair PartsCirculator Dimensions Tools and Material NeededTools Materials F36 Blower KIT Rules for Safe Installation and OperationLocating the Heater Trouble Shooting Tips for ModelCirculator Chimney ConnectionTypical Masonry Chimney Installation B Circulator Heater Venting Into a FireplaceDescription QTY Fireplace InstallationType a Fireplace Conversion Instructions for TWO-STEP Latch OperationChimney Maintenance CREOSOTE-FORMATION and Need for Removal Service HintsRules for Connector Pipe Installation Cabinet Door Catch AssemblyOperating Instruc Tions Adjusting the ThermostatBest results we recommend large nut coal to Burning Coal in Your Wondercoal Circulator

2847 specifications

The Little Wonder 2847 is an innovative piece of outdoor equipment that has gained popularity among gardening enthusiasts and landscape professionals alike. Known for its durability and efficiency, the Little Wonder 2847 combines advanced engineering with user-friendly features, making it a top choice for both residential and commercial landscape maintenance.

One of the standout features of the Little Wonder 2847 is its powerful engine. Equipped with a robust Honda GX160 engine, the machine delivers reliable performance and exceptional efficiency. This engine allows the Little Wonder 2847 to handle various tasks, from leaf blowing to debris clearing, with ease. With a high air velocity, users can efficiently clear large areas, ensuring that their landscaping efforts maintain a pristine appearance.

In addition to its powerful engine, the Little Wonder 2847 also boasts an ergonomic design that prioritizes user comfort. The adjustable handle makes it suitable for operators of different heights and provides a comfortable grip during extended use. This design consideration reduces strain on the operator's back and arms, allowing for improved productivity and less fatigue.

The machine is equipped with a durable, steel frame that can withstand the rigors of daily use. This rugged construction ensures that the Little Wonder 2847 can handle the demands of both residential yards and commercial properties, providing years of dependable service. The design also features strategic weight distribution, which enhances stability while in operation.

Another notable characteristic of the Little Wonder 2847 is its versatility. It is designed to be easily transportable, with a compact size that allows it to navigate through tight spaces and around obstacles. This feature makes it ideal for use in various environments, from suburban gardens to larger commercial properties.

The Little Wonder 2847 is also equipped with advanced technology that enhances its performance. Its superior air filtration system ensures that debris is easily collected, preventing clogging and ensuring smooth operation. Additionally, a quick-release mechanism allows for effortless maintenance, making it easy for users to clean filters or perform routine checks.

In conclusion, the Little Wonder 2847 is a powerhouse in the outdoor equipment market, combining a strong engine, ergonomic design, durability, and advanced technology. Its versatility and ease of use make it an excellent choice for anyone looking to maintain and enhance outdoor spaces efficiently. Whether for personal use or professional landscaping, the Little Wonder 2847 proves to be an invaluable tool in achieving landscaping goals.