Knoll Systems MR64 installation instructions SET a, RB8 Remote Control Functions

Page 3

necessary to have the source wires connected to program the MR64 labels.

Using the back of this manual, please write down the source name connected to source A, source B, source C and source D.

Turn the MVP44a, MVP64a on using the power button on the front panel or the MR640 by connecting the power supply. As soon as the power is turned on the MR64 will first show which software revision it is programmed with, display “Knoll Systems” and then display “System Off”.

Labels can only be programmed or changed by entering the MR64 installer menu when the LCD displays “System Off”. All of the available labels are the same for all four sources.

To enter the installer menu from “System Off” press the MR64 keypad (not remote) MUTE button for about 1 second then immediately press the INPUT for about 5 seconds. Release the INPUT button as soon as the LCD displays

SET A

Source A

Now press the UP or DOWN buttons next to the INPUT buttons to scroll through the label selections for source A on the bottom row of the LCD display. When the correct selection is displayed press the MUTE button to confirm this choice.

Note: If a mistake is made, go though the rest of the programming setup and restart the installer mode again.

The LCD display then displays

SET B

Source B

SET C

Source C

As above press the UP or DOWN buttons next to the INPUT buttons to scroll through the label selections for source C on the bottom row of the LCD display. When the correct selection is displayed press the MUTE button to confirm this choice. The LCD display then displays

SET D

Source D

As above press the UP or DOWN buttons next to the INPUT buttons to scroll through the label selections for source D on the bottom row of the LCD display. When the correct selection is displayed press the MUTE button to confirm this choice. The LCD display then displays

System

Off

And the MR64 labels have been set. To change any of the labels you can re-enter the installer menu and scroll through all four labels and reset the ones needed.

MR64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCD display

Input

 

 

 

Line 1

 

 

 

 

 

 

 

 

Volume up

 

 

 

 

 

 

 

 

 

 

 

select

 

 

 

Line 2

 

 

 

 

 

 

and down or

button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

source select or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sets backlighting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volume

 

 

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All button for

 

 

 

VOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

button

 

 

 

 

 

 

 

 

 

 

 

 

whole house

 

 

 

 

 

 

Mute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUTE

 

 

 

 

ALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

button

 

 

 

 

 

 

 

 

 

 

Shut off this room

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

Infrared

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or shut off whole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

house (press for

receiver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 seconds).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RB8 Remote Control Functions

As above press the UP or DOWN buttons next to the INPUT buttons to scroll through the label selections for source B on the bottom row of the LCD display. When the correct selection is displayed press the MUTE button to confirm this choice. The LCD display then displays

Power: switches room off or whol house off(press for 5 seconds)

Input 1-4: Turns on room and selects input music source

POWER

1 2

3 4

INPUT

systems

MUTE

+

VOL

-

RB8

Mute: Mutes music. to restore, press mute, input 1-4 or volume up/down

Volume Up/Down Press and hold for continuous volume changes

Image 3
Contents Music system consists Setting the dipswitchProgramming MR64 Labels Keypad WiringSET a RB8 Remote Control FunctionsSource Labels
Related manuals
Manual 2 pages 28.41 Kb

MR64 specifications

The Knoll Systems MR64 is a sophisticated hardware platform designed to meet the demands of modern audio and video distribution systems. As part of the renowned Knoll Systems lineup, the MR64 brings together advanced features and cutting-edge technology to deliver exceptional performance and functionality in AV applications.

At its core, the MR64 is a multi-room audio and video distribution system, ideally suited for both residential and commercial environments. One of its standout features is the ability to handle up to 64 zones of audio and video distribution, ensuring that users can enjoy content in multiple locations simultaneously without any compromise in quality or reliability. This makes the MR64 an ideal choice for large homes, conference centers, hotels, and various other venues.

The MR64 utilizes a robust digital signal processing (DSP) engine that enhances audio clarity and allows for a broad range of sound customization options. Users can easily configure equalization settings, volume controls, and other parameters for each individual zone, ensuring a tailored experience that fits the specific needs of different environments and preferences.

In terms of connectivity, the MR64 is equipped with various input and output options, including HDMI, serial, and analog connections. This versatility allows it to integrate seamlessly with a wide array of devices, such as televisions, projectors, sound systems, and smart home devices. Additionally, the system supports both wired and wireless networks, providing flexibility in installation and operation.

One of the key characteristics of the MR64 is its user-friendly interface. The system can be controlled via a mobile app, touch panels, or desktop applications, making it easy for users to access and adjust settings from anywhere within the network. This level of control enhances the overall user experience and allows for quick adjustments on the fly.

In terms of performance, the MR64 boasts low latency and high fidelity, ensuring that audio and video signals are transmitted without noticeable delay. This is particularly important in settings where live performances or presentations occur, as it ensures that sound and visuals are perfectly synchronized.

Overall, the Knoll Systems MR64 offers a comprehensive solution for audio and video distribution that combines powerful technology, versatility, and ease of use, making it a top choice for anyone looking to enhance their AV experience. Its ability to support a wide range of applications, coupled with its advanced features, solidifies its position as a leader in the field of multi-room distribution systems.