Herrmidifier Co 707U-UK specifications Selecting a location for the unit

Page 5

Selecting a location for the unit

Mounting behind a wall using the discharge extension (707U only)

When selecting a location for the installation of your humidifier as a free standing unit, certain conditions must be met for its proper operation:

Locate the humidifier in a convenient spot where the working part of the humidifier can be hidden (i.e. closet, stairway, garage, utility room, etc.)

When deciding on the location of the humidifier, please keep in mind the following points:

The discharge nozzle should be at least two (2) feet below the ceiling and from a vertical wall along the side.

The discharge nozzle should be about six and a half (6 1/2) feet from the floor. If this is not possible, locate the humidifier in the area of least traffic.

The humidifier should be located between wall studs to facilitate cutting the discharge hole through the wall.

No obstructions should be directly in the path of the discharge mist for six (6) feet. This includes, but is not limited to ceiling lights, light cords and ceiling fans.

DO NOT install the humidifier where freezing conditions could occur.

Indicates recommended locations for free standing humidifiers

Indicates humidistat locations

4

Image 5
Contents Duct Mount Centrifugal Atomizer Humidifier Introduction SpecificationsIntroduction Operation This chart uses A.R.I. standard designationsCapacity Selection Guide Selecting a location for the unit Selecting a location for the unit Physical installation Following items are located in the carton Mounting behind a wall using discharge extension 707U only Physical installation Final installation steps for all mounting locations Electrical installation Electrical installationTo reach comfortable levels Humidistat installationHumidistat Maintenance To clean the unit Parts List Humidifier Limited Two Year Warranty Warranty