GSW Signature Series Electric manual Capacity & Performance, Height to Overall

Page 15

CAPACITY & PERFORMANCE

 

 

 

 

 

Height to

Height to

 

Overall

 

 

 

 

Recovery

 

Top of Blower

Top of Tank

Diameter

Depth

Shipping

 

Capacity

Input

@100˚F/55˚C Rise

Energy

A

B

C

D

Weight

Model

USG (Litres)

BTU

USG (Litres)

Factor

in. (cm)

in. (cm)

in. (cm)

in. (cm)

lb. (kg)

NATURAL GAS

 

 

 

 

 

 

 

 

 

JW40NVH-FV

40 (151)

33,000

30 (112)

0.60

58 (147)

48.5 (123)

21.13 (54)

26 (66)

155 (70)

JW50NVH-FV

50 (189)

38,000

34 (129)

0.60

60.5 (154)

51 (129.5)

22.63 (57)

27.25 (69)

187 (85)

JW5065SNV-FV*

50 (189)

65,000

59 (223)

0.60

60.75 (154)

51.25 (130)

22.63 (57)

27.25 (69)

200 (90)

JW5065LNV-FV*

50 (189)

65,000

56 (212)

0.60

60.75 (154)

51.25 (130)

22.63 (57)

27.25 (69)

200 (90)

LIQUID PROPANE

 

 

 

 

 

 

 

 

 

6G40PVH-FV

40 (151)

33,000

30 (112)

0.60

58 (147)

48.5 (123)

21.13 (54)

26 (66)

155 (70)

6G50PVH-FV

50 (189)

38,000

34 (129)

0.60

60.5 (154)

51 (129.5)

22.63 (57)

27.25 (69)

187 (85)

6G65SPV-FV

50 (189)

65,000

59 (223)

0.60

60.75 (154)

51.25 (130)

22.63 (57)

27.25 (69)

200 (90)

High altitude, 0-4500', models are de-rated by 10% as per CSA. * Side taps

9

An advanced line of power vented water heaters for the professional.

John Wood® Power Vent

Image 15
Contents Page Another hot water solution from John Wood Table of Contents Tankless Products GSW Water Heating GSW Water Heating Residential Page GSW Safety Systems Proven Technology. Exceptional Reliability. Peace-of-mind Residential GasModel Natural GASResidential Propane Propane Top Jacket VentUSG Litres John Wood Power Vent Height to Overall Capacity & PerformanceLarge capacity power vent water heaters Height to Approx VentJohn Wood Power Direct Vent Height to Capacity & DimensionsUnique balanced flue design John Wood Direct VentDirect Vent Clearance MaxLitres Optimum in reliability, performance and energy efficiency Residential ElectricElectric SpaceSaver Put hot water right where you need itTop Entry Double Element Models Side Entry Single Element ModelsExclusive, patented innovation Residential OilCapacity and Performance ROUGH-IN DimensionsBeckett Oil Fired BurnersBeckett Oil Burners GPH Input BTU Input J3006Burner for Direct Vent Model JWF307V Quiet and efficient way to heat water PolarisModel Litres Input In. cm Residential GAS PolarisHeight Cold Heating Inlet OutletStorage Booster Tanks Capacity Water Connections Height Diameter Shipping Weight Valve conveniently located on the side FlowTHRUUSG/IMPGallon/Litres Capacity DimensionsShipping Weight Lb. kg Diameter B In. cm Height a In. cmIndirect Water Heaters JW5-40IT 45.5 42.5 160 JW5-75IT First Hr. Rating ContinuousFlow JW5-30ITCapacities from 2 to 119 US Gallons Diaphragm Pump TanksLb kg Pump Tank SpecificationsWeight Overall To CenterThermal Expansion Tanks Perfect solution for controlling thermal expansionExpansion Tank Specifications Maximum Maximum Accepted Volume USG LitresTank Volume Glass-lined, painted tank Range BoilerCommercial Page Proud tradition of leadership Signature SeriesSignature Series Gas Proud tradition of leadership Signature Series Propane JWSC75-125P De-rate Kits 100 59029 Power Vent KitsMax. Equivalent Vent Diameter Weight 59028Custom built-to-order Signature Series ElectricSignature Series Electric High output, high efficiency Commercial Oil379 RecoveryDiameter Flue Diameter Water Shipping Model JWF657 68.75Available in 80 and 119 US Gallon models Signature Series Storage TanksHeight to Upper Lower Handhole Drain Storage TanksLight Duty Commercial Gas Models Capacity Recovery @ Top of Vent DiameterLight Duty Commercial Electric Capacity Max. No Volts Max Model Gallons Elements PhasePolaris Model Litres Input In. cm Lb. kg Commercial GAS PolarisJohn Wood Signature Series Gas Commercial Water Heaters are Designed specifically for professional installersTankless Page John Wood by Noritz Tankless for professionals Min.+ Max Height Width Depth Vent Model ApplicationIn. cm In. mm Lb. kg Page Appendices Page Cross-Over Matrix Commercial GAS Cross Reference ChartJWSC75-300 G100-310 Sizing Guide # of Units# of Stations # of Units Model Commercial Gas Water Heater Quick Sizing GuideOhms Law Reference Guide for Water Heating Temperatures Oil vs. Electric vs. Propane vs. Natural Gas Formula for mixing hot water Electric GAS Conversions Innovative Designs, Built-to-Last Warranty