REPLACEMENT INSTRUCTIONS
Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect the power cord from the wall outlet before replacing any of the parts below.
REPLACING THE FLAT BELT
Remove the bottom plate.
1 (refer to page 14)
Lift out the agitator assembly,and then remove the flat belt from the motor shaft and
2 the agitator pulley.
Motor Shaft
Flat Belt
3 Place a new flat belt onto the motor shaft and pulley.
Motor Shaft
Flat Belt
Flat Belt
Pulley
Place the agitator assembly into the grooves in the nozzle head, making sure that the new
4 flat belt slides securely into the guide.
Bearing Holder
Groove
Nozzle Head
Reattach the bottom plate
5 (refer to page 14)
Caution:
Install the flat belt so that it has no twists in it,and so that all components turn smoothly.
13