Electrical Specifications
1. All wiring must comply with local and national electrical codes and must be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3. This 115V air conditioner uses 10.1 or less (depending on model) nameplate amps and may be used in any properly wired, general purpose household receptacle. See Table 1 for specifications for individual branch circuit.
4. For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If
you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.
5. The wall outlet
6. The rating plate on the unit contains electrical and other technical data.
Table 1: Suggested Individual Branch Circuit
Nameplate Amps | AWG Wire Size* |
4.9 to 10.1 | 14 |
AWG- American Wire Gage
* Based on copper wire at 60 °C temperature rating.
Table 2: Receptacle and Fuse Types
Rated Volts | 125 | ||
Amps | 15 |
| |
|
|
|
|
Wall Outlet |
|
|
|
|
|
| |
|
|
| |
|
|
|
|
Fuse Size | 15 |
| |
Time Delay Fuse | Plug Type | ||
(or circuit breaker) |
|
|
|