Americair 2500HV, 8500 & 10000, 4000HV, 6000V, 6500 Table of Contents, Specifications, Introduction

Page 2

Table of Contents

Rules for Safe Installation and Operation

................1

Maintenance

12

Shipping and Packing List

1

Filter Change Schedule

12

Specifications

2

Filter Changing Guidelines

12

Introduction

2

Dealer Filter Change Instructions

13-14

General Information

3

Dealer Motor Assembly Replacement Instructions

15

Product Application Guidelines

3

Electrical Diagram

15

Parts Identification

4-6

Replacement Parts

16

Physical Dimensions of Units

7-8

 

 

Dealer Installation Instructions

9-11

 

 

Operation

12

 

 

Specifications

 

2500HV

4000HV

6000V

6500

8500

10000

Nom. Air Flow @ 120VAC @ 0.0” E.S.P.

175 cfm

300 cfm

600 cfm

650 cfm

850 cfm

1000 cfm

Weight (max - unpackaged)

25 lbs.

27 lbs.

58 lbs.

120 lbs.

125 lbs.

130 lbs.

Supply Voltage

120 VAC

120 VAC

120 VAC

120 VAC

120 VAC

120 VAC

Nom. Measured Power Consumption

125 Watts

125 Watts

160 Watts

250 Watts

360 Watts

600 Watts

Motor Current Draw - Total

1.0 amps

1.0 amps

1.0 amps

2.1 amps

3.6 amps

4.8 amps

Air Intake Collar (max)

6”-round

6”-round

10”-round

10”x12”

10”x12”

10”x12”

Air Outflow Collar (max)

6”-round

6”-round

8”-round

10”x12”

10”x12”

10”x12”

Operating Temp. Range - Return air (ºF)

30 to 95

30 to 95

30 to 95

30 to 95

30 to 95

30 to 95

HEPA filter efficiency = 99.97% @ 0.3 micron particles

Ambient temperature range: -40ºF to 130ºF

Introduction

Congratulations! You will quickly realize that you have purchased a very effective air cleaning system. It incorporates state of the art HEPA (High Efficiency Particulate Air) technology.

Your Amaircare HEPA system comes with a limited warranty. With proper attention to its care and mainte- nance, you will receive optimum performance.

If your indoor air has abnormally high concentrations of particulates, the life span of the filter media may be shortened. Excessive particulates in the air will reduce the expected life of the HEPA filter. Under nor- mal conditions the HEPA filter will last from two to five years.

The optional activated carbon canister has a finite limit as to the amount of odor or other gaseous volatile organic compounds (V.O.C.’s) that it can adsorb. The higher the concentrations, the shorter the expected life. Higher humidity may shorten the life of the carbon canister. Under normal conditions, the carbon canister

should last up to 12 months.

Initially, the HEPA filter’s particulate removal efficiency improves with use. However, the air flow through the HEPA filter media will decrease, as dust builds up on the filter, thus lowering its ability to circulate and clean as much air as when it was new. If the air flow through your unit is noticeably reduced, you can inspect the pre-filter and HEPA filter to see if they should be replaced. Replacement (or washing if foam) of the pre- filter every 3 months will help extend the life of the HEPA filter.

Please contact your local Amaircare dealer regarding replacement of filter media, warranty information or if you have any questions or concerns about the perfor- mance of your HEPA system.

NOTE: This filtration system is an ADDITIONAL filter, and does NOT replace the existing air handler/furnace system filter.

2

Image 2
Contents Hepa System Models Rules for Safe Installation and OperationShipping and Packing List For Models 2500HV, 4000HV, 6000V, 6500, 8500Introduction Table of ContentsSpecifications Size of House vs. Air Changes per Hour General InformationProduct Application Guidelines Parts Identification 2500HV 4000HV Parts IdentificationParts Identification 6500, 8500 Filter Parts Identification Hepa Cartridge Parts 6500, 8500Physical Dimensions of Unit Model 2500 & 4000HVFilter Section Access Panel Motor Section Access Panel Models 6500, 8500 Air Intake Air OutflowDealer Installation Instructions Example of Return to Return InstallationForced air handler/furnace system with an HRV/ERV With an HRV/ERVExample of Single Room Stand Alone System Installation Independent OperationMaintenance OperationDealer Filter Change Instructions 2500HV, 4000HV Dealer Filter Change Instructions 6500, 8500 Dealer Motor Assembly Replacement Instructions Electrical DiagramReplacement Parts Replacement Parts for 6000V Qty Canadian International
Related manuals
Manual 8 pages 30.99 Kb

2500HV, 6000V, 8500 & 10000, 6500, 4000HV specifications

The Americair series, including the models 4000V, 8500, 10000, 6500, and 5000V, represents a significant advancement in air purification technology. Designed for commercial and industrial applications, these units are engineered to enhance indoor air quality while ensuring maximum efficiency and user convenience.

One of the standout features across these models is the use of advanced HEPA filtration system. HEPA filters are designed to capture at least 99.97% of airborne particles, including dust, pollen, smoke, and other allergens, down to 0.3 microns in size. This capability is crucial for environments that demand stringent air quality standards, such as hospitals, schools, and offices.

The Americair 4000V model is tailored for smaller spaces, yet it packs a powerful punch with a CADR (Clean Air Delivery Rate) that ensures rapid air cleaning. It's particularly suited for rooms up to 400 square feet, making it ideal for small businesses and home offices. The user-friendly interface allows for easy adjustments, and the lightweight design ensures portability.

Moving up in capacity, the Americair 5000V and 6500 models cater to medium-sized rooms, providing enhanced CADR levels. These units incorporate smart technology, allowing for app connectivity, enabling users to monitor air quality in real time and receive notifications for filter changes.

The Americair 8500 and 10000 models are designed for larger spaces such as auditoriums and open-plan offices. With high-performance motors and multi-stage filtration systems, these models not only purify the air but also circulate it efficiently. Additionally, they come equipped with UV-C light technology, which works to eliminate germs and bacteria, enhancing health safety in populated areas.

All models feature energy-efficient designs, ensuring they consume less power while maintaining high performance levels. Noise reduction technology is also integrated, making these units operate quietly, an essential factor for environments requiring minimal disruption.

In conclusion, the Americair series stands out with its combination of powerful filtration, energy efficiency, and user-friendly technology. Whether for a small office or a large industrial space, these models provide versatile solutions for improving indoor air quality, promoting a healthier environment for all.