AllerAir 6000, 5000 To Begin Using the AIR Purifier, Additional Information, Important Notice

Page 4

TO BEGIN USING THE AIR PURIFIER

Wipe the unit with a damp cloth.

Plug the unit into a grounded 110 outlet.

Turn the unit on at TURBO and let it run for a moment.

Place the unit in the desired area and set at HIGH for regular daytime use and at LOW for overnight.

The most effective way to use the air purifier is to run it on low

TO REPLACE OR CLEAN THE PRE-FILTER

ALLERAIR'S AIR PURIFICATION SYSTEM

LASER TESTED TRUE HEPA

HEPA (Hight Efficiency Particulate Arrestance) filters were develped for the Atomic Energy Commission to remove radio active dust from their laboratories. The are now the primary filtration systems for electonic clean room assembly, hospital surgeries, bio engineering, pharmaceutical laboratories and any other space where clean air is critical.

HEPA will trap microscopic dust which will give you distress from allergies, asthma, respiratory problems, chemical sensitivities and sick building syndrome. It will trap 99.97% of all particles down to 0.3 microns (including bacteria, dust mite antigens, respiratory particles, fungal and other microbiologicals. For these reasons that HEPA filtration is recommended by more allergists, medical professionals and clean air consultants than any other filter system available.

CARBON FILTER (ACTIVATED AND GRANULATED)

We use only activated granular carbon mixed with zeolite and specially impregnated carbons. We stay away from dust carbon which has been impregnated onto a poly or foam material. This type of carbon filter has to be changed as often as every week to be fully effective. AllerAir's carbon filter can last up to 2 or 3 years and more, depending on the level of toxins in the area.

STEP A

Turn off the unit. Unplug the unit. Gently tilt over the unit.

STEP B

Remove the pre- filter

gently to avoid disturbing the dust on it.

Either

Vacuum the pre-filter

on both sides and replace.

STEP C

Replace the new or cleaned pre-filter by gently pressing against inner carbon filter.

Gently return the unit to the upright position.

The activated carbon we use is derived from coconut shell and can adsorb up to 60% of its own weight in toxic gases, fumes and chemicals. These toxic substances make us ill, and are found in every home, office and industry.

OTHER FILTERING SYSTEMS AVAILABLE

Ozone generators, negative ion machines and electrostatically charged units all generate ozone which is a toxic substance. Any unit which provides ozone cannot be recommended by Health and Welfare or by the Lung Association.

AllerAir's units on the other hand do not produce any ozone whatsoever. The latest air purification technology does not add anything to the air (especially impurities like

Or

Place the old pre- filter in a garbage bag for disposal.

Pre - filter : Vacuum every 1 or 2 months. Replace when necessary.

Warning

Before removing the top or bottom off the unit for any reason, unplug the unit.

Do not allow any object to be stuck or paked into any opening of the unit. (i.e. louvers or control knob.)

Prefilters Order Guide*

Models

Prefilters

4000

5000

6000

8000

Notes

Exec, Vocarb

Poly Prefilters

A4FMP006

A5FMP009

A6FMP012

A8FMP008

packs of 4 or 8

DS Models

Tacky Prefilters

A4FMPS06

A5FMPS09

A6FMPS12

 

packs of 10

MCS Models

Cotton Prefilters

A4FCP016

A5FCP019

A6FCP022

 

packs of 6

*Please use the above part numbers when ordering your replacement parts

2

AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com

ozone or P.V.C.s). AllerAir's unit scrubs impurities and toxins out of the air.

ENERGY COSTS

We use a high efficiency motor which cost pennies a day to operate in contrast to almost all other manufactures who use the lowest price motor available. One of the reasons we can offer a five year extendible to ten year warranty is because of the sophisticated motor we use. We have spared no effort to give you the most for the least.

ADDITIONAL INFORMATION

The rush of air on "Low", makes less noise which is often used to help people sleep more soundly. Use "High" in work places or home living rooms. Use "Turbo" when you are out of the area for the day or night. The sound you hear from the unit is the sound of the air passing through the vent to achieve a current so that your complete area will receive changes of air.

The air coming out of the unit may feel cool to your hand, but the temperture of the air is actually the same. And AllerAir units are specially designed to have no offgasing because our entire unit housing is made of steel.

IMPORTANT NOTICE

To receive maximum use of HEPA filter media when used in freshly painted room, you should first remove the HEPA filter from the unit to avoid contaminating the HEPA media. Turn unit off and Ungplug unit. Remove bottom screws. Open bottom of unit, Grasp outer filter ring firmly with both hands and remove carefully. Close unit, plug into grounded receptacle then turn on. Replace carbon filter before reinstalling HEPA filter.

Do not allow any object to be stuck or poked into any opening of the unit.

 

Never service the unit before turning unit off and removing electrical plug

7

from the wall receptacle.

 

AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193

www.allerair.com

 

Image 4
Contents Operation AllerairReplacement Carbon Filter Order Guide Microparticulate Electrostatic Filter Order GuideStep Models 4000 5000 6000 8000Hepa Filter Order Guide To Replace UV Bulb and Ballast To Replace the Hepa FilterStep Hepa filter 3 to 5 years depending on useTo Begin Using the AIR Purifier Additional InformationImportant Notice Prefilters Order Guide

5000, 6000 specifications

AllerAir 5000 and 6000 series air purifiers are designed to provide superior air quality for those who suffer from allergies, asthma, or are simply looking to enhance their indoor air environment. Both models utilize advanced technologies and features to create a healthier living space.

The AllerAir 5000 model is known for its effective multi-stage filtration system, which includes a combination of HEPA, activated carbon, and pre-filters. The HEPA filter captures 99.97% of airborne particles as small as 0.3 microns, making it effective against dust, pollen, pet dander, and mold spores. The activated carbon filter effectively removes volatile organic compounds (VOCs), odors, and harmful chemicals, providing a breathe-easy atmosphere while ensuring that indoor air is free from pollutants. Additionally, the pre-filter helps to extend the life of the HEPA and carbon filters by trapping larger particles.

On the other hand, the AllerAir 6000 series takes air purification to a higher level. It features an even larger activated carbon filter that significantly increases its ability to eliminate more contaminants, particularly in environments with high levels of chemical pollutants or industrial emissions. The 6000 series is often favored in larger spaces or areas with heavy odor issues due to its enhanced filtration capacity and airflow performance.

Both units are equipped with AllerAir’s unique Air Quality Indicator, which provides real-time feedback on the air quality, allowing users to adjust settings accordingly for optimal performance. The easy-to-use control panel allows for fan speed adjustments and filter replacement notifications, ensuring user convenience.

A standout feature of both the 5000 and 6000 series is their silent operation, making them ideal for bedrooms, offices, and other quiet spaces. They also feature durable, all-metal cabinetry that enhances their durability and aesthetic appeal.

In summary, the AllerAir 5000 and 6000 series air purifiers combine innovative filtration technologies with user-friendly designs to offer effective solutions for improving indoor air quality. They are perfect choices for individuals looking to mitigate allergens and pollutants while enjoying the benefits of cleaner, fresher air in their environments.