Trion Supreme Series warranty Typical Mounting Positions, Application, Installation Requirements

Page 6

Installation

TYPICAL MOUNTING POSITIONS

(Air cleaner shown shaded in illustrations)

WARNING

Before making changes to a HVAC system that may affect the ventilation of fuel-burning appliances, contact your heating contractor.

Transitions

Transitions

Basement Furnace

Counterflow

Space Saver

(Lowboy) -Mounted

Furnace–

Furnace

horizontally in return

Mounted

(Highboy)- Side

plenum– just above

horizontally in

installation.

return duct–

the furnace.

Mounted

just above the

 

vertically, where

 

furnace.

 

return air enters

 

 

 

 

side inlet of

 

 

furnace.

 

 

Before

 

After

 

Horizontal Furnace–

 

 

 

Offset Installation– If there is less

Mounted vertically in return

than 7-in. for mounting the air

duct as close to the furnace

cleaner between the duct and the

as possible.

furnace, move the return air drop.

Installation

Application

This air cleaner is used in forced air heating, cooling, and ventilating systems. The air cleaner should be installed in the system such that all the system air is circulated through the air cleaner. Maximum performance is obtained with the system blower set for continuous operation.

Installation Requirements

The best location for the air cleaner is in the return air duct next to the blower compartment. In this location, the blower motor and cooling coils will be kept clean. Do not install the air cleaner in the discharge air duct. Before installing the air cleaner, consider the application. If a transition between the ductwork and air cleaner is required, refer to section entitled Transitions, below. The unit must be readily accessible for periodic inspection and replacement of the filter cartridge to maintain maximum efficiency and trouble-free operation. A clean coil will reduce utility costs by maintaining the coil’s efficiency. Failure to replace filter cartridge can cause damage to the cooling system. Allow a minimum of 26” clearance in front of the access panel for filter cartridge replacement.

Transitions

If the air duct does not fit the air cleaner cabinet opening, gradual transitions are recommended to reduce air turbulence through the air cleaner and maximize efficiency. Not more than 20° (about 4” per running foot) of expansion should be used on each side of the transition fitting.

Maximum 4" drop per linear foot

Air Flow

 

 

CleanerAir

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Flow

opening

 

Furnace opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Furnace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Cleaner

Transition section

4

5

Image 6
Contents Warranty Media AIR Cleaner Limited TEN-YEAR WarrantyTable of Contents Maintenance IntroductionSteps for Replacing Filter Cartridge Physical Installation Unit DiagramInstallation Prior to Installing this ProductTurning Vanes DimensionsDirection of Air Flow Through the Air Cleaner HumidifiersApplication Installation RequirementsTypical Mounting Positions Transitions