Utica Gas-fired Boiler manual General Instructions, Do not Over OIL

Page 18

GENERAL INSTRUCTIONS

Before seasonal start-up, have a competent service agency check the boiler for soot and scale in the flues, clean the burners and check the gas input rate to maintain high operating efficiency.

CAUTION:

Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation.

Verify proper operation after service.

The service agency or owner should make certain the system is filled with water to minimum pressure and open air vents, if used, to expel any air that may have accumulated in the system. Check the entire piping system and if any leaks appear, have them repaired.

Many circulators like the one pictured in figure 17 below, require periodic servicing. The motor usually has openings at each end to lubricate the bearings. Put about one half teaspoon of SAE 20 or 30 non-detergent motor oil in each opening twice a year.

CAUTION:

DO NOT OVER OIL.

FIGURE 17

FIGURE 18

Many circulators have an oil opening for the shaft bearing. This should be oiled at the same time for quiet operation. Follow the manufacturer's instructions for oiling the shaft bearing.

The venting system should be inspected at the start of each heating season. Check the vent pipe from the boiler to the chimney for signs of deterioration by rust or sagging joints. Repair if necessary. Remove the vent pipe at the base of the chimney or flue and using a mirror, check vent for obstruction and make certain the vent is in good working order.

The boiler flue gas passageways may be inspected by a light and mirror. Remove the burner door, figure 18. Place a trouble lamp in the flue collector through the draft relief opening. With

PAGE 17

Image 18
Contents MGB Table of Contents Safety Symbols IMPORTANT! Read ALL Instructions Before InstallingInstallation Procedure Ventilation & Combustion AIR Combustion AIR RequirementsPage Connecting Supply and Return Piping Bypass Piping Primary Secondary Piping with by Pass Vent Installation Vent System Modification Removal of Boiler from Venting SystemVent Damper Installation and Instructions InstallationInstructions Connecting GAS Service Do not USE AN Open FlameSee Addendum a for Wiring Diagrams Component Coding Electrical WiringThermostat Installation Lighting InstructionsFor Your Safety Read Before Operating What to do if YOU Smell GASLighting Procedure for Boiler With Continuous Pilot For Your Safety Read Before LightingTo Turn OFF GAS to Appliance Normal Sequence of OperationNot Force General Instructions Do not Over OILPage Checking GAS Input Rate to Boiler MGB Series Replacement Parts Rollout & Spill Switch MGB Series Replacement Parts Pilots MGB Series Replacement Parts Base MGB Series Replacement Parts Jackets Panel TOP MGB150MGB Series Replacement Parts Heat Exchanger Right SectionMGB Series Replacement Parts Piping & Controls Ratings and Data Natural GAS and Propane GAS =B=RMGB Series Dimensions for Natural GAS and Propane GAS

Gas-fired Boiler specifications

The Utica Gas-fired Boiler is a highly efficient heating solution designed for residential and commercial applications. Recognized for its reliability and durability, the Utica Gas-fired Boiler utilizes gas as a clean energy source, which not only reduces emissions but also lowers operational costs. With various models available, this boiler caters to a wide range of heating needs, making it a versatile choice for different environments.

One of the main features of the Utica Gas-fired Boiler is its impressive energy efficiency. Many models are equipped with advanced combustion technology that ensures optimal fuel utilization, resulting in lower gas consumption and environmental impact. This efficiency is often reflected in high AFUE (Annual Fuel Utilization Efficiency) ratings, confirming the boiler's ability to convert a significant portion of fuel into usable heat.

The Utica Gas-fired Boiler employs a diversified product line, which includes both steam and hot water boiler systems. This flexibility allows users to choose the system that best suits their heating requirements. Additionally, the boilers are designed with user-friendly controls that facilitate easy operation and maintenance.

In terms of technology, Utica integrates multiple innovative features into their gas-fired boilers. The use of a modulating gas valve enables the boiler to adjust its output to match the heating demand, promoting energy efficiency and comfort. Many models also utilize a sealed combustion design that pulls in outside air for combustion, enhancing safety and improving performance in tightly sealed homes.

Moreover, the construction of Utica Gas-fired Boilers emphasizes durability. They are built from high-quality materials like cast iron or stainless steel, ensuring a long lifespan and resistance to corrosion. The robust design also facilitates easy servicing, with accessible components that minimize downtime in the event of maintenance or repairs.

Safety is another critical aspect of the Utica Gas-fired Boiler design. Features such as built-in safety controls, pressure relief valves, and flame rollout switches contribute to a safer operating environment.

In conclusion, the Utica Gas-fired Boiler exemplifies an exceptional heating solution characterized by efficiency, flexibility, and durability. With advanced technologies and a strong commitment to safety, it remains a preferred choice for those seeking reliable heating options for their spaces. The combination of low emissions, high performance, and user-friendly operation makes it ideal for modern heating applications.