Sebo K2 owner manual Additional Operating Instructions for K3 with Power Head

Page 9

ADDITIONAL OPERATING INSTRUCTIONS FOR K3 WITH POWER HEAD

Please refer to your power head owner’s manual for more information

Starting The Machine and Suction Control - Figures 1, 2, 8, 9, 10a & 10b

Before turning on your canister, make sure that the vacuum handle is in its upright locked position (figure 8).

1.With the canister main power control knob (9) in the OFF position, and the power control slider on the handle (#2, figure 9) in the OFF position, pull the power cord out from the base of the canister (figure 1). The power cord should be unwound from the cable reel at least two thirds of its length. Note: do not over-extend the cord.

2.Plug the polarized power cord into a 120 volt wall outlet located near the floor.

3.Press the main power control knob (9) on the base of the canister gently with your foot or hand. The green light (10) will illuminate indicating that the power is on (figure 2).

 

40

ET-H power head

ET-1 power head

Figure 8

4.Slide the Power Control Slider (2) to the ON position (the slider will “click” when it is pushed out of the OFF position). It will then slide freely between 0 suction and MAX suction. Set the slider to the suction desired. Release the foot pedal (#41, figure 10a) on the ET-1 or ET-2 power head or, for the ET-H power head, lower the handle (figure 10b).

Operating The Machine - Figures 10a & 10b

When the power head is on with the handle in the upright locked position (see figure 8 above), the brush roller will not spin.

2

To release the ET-1 or ET-2 power head from the upright locked position, press down on the foot pedal (#41, figure 10a) and lower the handle into the normal operating position and push the button on the top of the power head (#40, fig- ure 8) to engage the brush roller. The green light on the power head will illumi- nate.

Figure 9

0 = Zero Suction MAX = Maximum Suction

ON position - Slide the slider down toward 0 suction till it “clicks” out of position.

To release the ET-H power head from the upright locked position, gently place your foot on the power head for leverage and lower the handle into the operat- ing position (figure 10b). The brush roller will then start spinning. The amber indicator light may flicker for a few seconds when you lower the handle - this is normal.

The handle can be lowered to a horizontal position useful for vacuuming under beds.

You may adjust the suction control with the power control slider (2) as you vac- uum different surfaces or when using the accessory tools. For optimal cleaning and brushing, operate the machine at the maximum suction power setting and push the power head slowly over the carpet.

When the canister’s main power control knob is in the ON position, you may turn the power head off and on with the power control slider (2). To turn the power head off using the power control slider, pull the slider to 0 suction, then contin- ue pulling the slider up until it “clicks” into the OFF position. The green power head light will then shut off (the green light on the canister (10) will remain illu- minated until the vacuum is powered off using the main power control knob).

Always turn the power off on both the canister and the power head when changing heads or unplugging the vacuum. Slide the power control slider on the power head to its OFF position, press the power control knob on the base of the canister (9) gently with your foot or hand, then unplug the canister to com- pletely shut down the power when changing heads or storing the vacuum.

To retract the cord, switch the vacuum off, unplug it from the outlet, then gen- tly pull on the cord near the plug recess (22) and the mechanism will automat- ically rewind. Before rewinding the cable, always switch off and unplug the vac- uum. Hold the plug while rewinding the cord onto the cord reel. Avoid letting the plug whip while rewinding.

OFF position - Pull the slider up to 0 suc- tion then continue pulling the slider up until it “clicks” into the OFF position.

41

Figure 10a

Figure 10b

9

Image 9
Contents For Household Use Only Technical Details Table of ContentsRead ALL Instructions Before Using this Machine Important Safety InstructionsSebo Airbelt K Product Features Designed for All Floor Surfaces Optional ATTACHMENTS, ACCESSORIES, Bags & Filters Optional Power Heads for the Airbelt K3Identification of Parts AssemblyStarting The Machine Figures 1, 2 Suction Control FigureOperating the Machine Figures 4, 5, 6 Operating The Machine Figures 10a & 10b Additional Operating Instructions for K3 with Power HeadUsing the Telescopic Tube, Hose & Attachments Figures 11 USE and Maintenance of Brushes and HeadsPremium Parquet nozzle Figure Combination nozzle FigureChanging the Filter Bag Figure Vacuum MaintenanceChanging the Exhaust Filter Figure Changing the Micro-Hygiene Filter Figures 16 &18Clogs in the Head or Brush Figure Clog RemovalClogs in the Telescopic Tube Figure Clogs in the Hose Figures 21, 22Problem Reason Solution TROUBLE-SHOOTING GuideCanister with Handle/Hose Airbelt K2 Schematic and Parts ListDescription Airbelt K3 Schematic and Parts ListFive Years Non-Wear Parts Five Years Motor One Year Labor Sebo Vacuum Cleaner Warranty