Security 100 KE-265 manual Tamper Alarm Lockout

Page 8
Tamper Alarm Lockout

Latching Authorization

Placing jumpers across the 4th Ex: Latching Authorization and 5th set of pins (1,2 LATCH

or 3,4,5 LATCH) determines which relay (if any) each User Group is authorized to manually latch.

How to Latch

When a valid code is entered on the keypad followed by “7”, the Latch

Authorization relay for that particular User Group will energize and remain energized until a valid code followed by “7” is entered again.

Example:

1.Placing a jumper across the 1st and 2nd pins of the “1, 2 LATCH” option allows User 1 and User 2 to Latch Relay #2.

2.Leaving a jumper off the “3,4,5 LATCH” option prevents User 3, User 4 and User 5 from latching either relay.

 Note: Because the Master Code is primarily used to program User codes, the Master Code does not have Latching Authorization.

CCTV/Doorbell Setup

Placing jumpers across the 6th or Ex: CCTV Setup 7th set of pins (CCTV or

DOORBELL) determines which relay (if any) will be used to activate a CCTV or Doorbell.

CCTV Operation: If either relay is configured to activate a CCTV, any key press on the Keypad triggers a 10 second output.

Doorbell Operation: If either relay is configured to activate a doorbell, pressing at the Keypad triggers a 1 second output. (Doorbell only functions with 12-Pad 3x4 or Thinline 2x6)

2nd Door Operation The KE-265 has been

designed to provide 2 door Ex: 2 Door Configuration operation with one or more

Keypads. With this configuration, certain codes will activate Relay #1 and certain codes will activate Relay #2. (Connect Relay #2 to the 2nd Locking Device)

Example:

1.Placing a jumper across the 2nd and 3rd pins of the “MASTER UNLOCK” option allows the master code to activate (unlock) Relay #1.

2.Placing a jumper across the 2nd and 3rd pins of the “1,2 UNLOCK” option allows User Code 1 and User Code 2 to activate (unlock) Relay #1.

3.Placing a jumper across the 1st and 2nd pins of the “3,4,5 UNLOCK” option allows User Code 3, User Code 4 and User Code 5 to activate (unlock) Relay #2

4.In this example, User Code 1 and User Code 2 have also been given Latching Authorization for Relay #1.

Note: In order for 2 Door configuration to operate correctly, be sure to remove any jumpers across the CCTV option and the Doorbell option.

Tamper Alarm Lockout

A person attempting to gain entry by guessing the code and pushing 25 wrong digits will cause the KE-265 to go into tamper alarm mode. The Keypad will beep constantly for 30 seconds during which time the door will remain locked and no keypad functions can be performed.

12

13

Image 8
Contents KE-265 Keyless Entry Access Control SystemInstallation and Operations Manual Table of Contents ESSEX ELECTRONICS, INCKE-265 Series Document InformationSystem Specifications IntroductionOverview Input RequirementsSystem Components Preparing for InstallationKeypad Options Required Tools The Installation ProcedurePrepare the Keypad for Installation Install the Wiring Cable Installing the Control ModuleConnecting the Locking Device Battery BackupSystem Hardware Setup Setting Relay OptionsRemote By-Pass Anti-TailgatingTamper Alarm Lockout System Programming Overview of System Code ProgrammingOverview of the Master Code Programming the Master CodeDefault Î 5 seconds Programming User CodesProgramming Door Open Time Troubleshooting I Changed or Deleted a code, but the old code still unlocks the doorThe Door opens with the first press on the Keypad Keypad is completely deadRepair Policy Repairs and Warranty5 YEAR LIMITED WARRANTY Appendix A - Circuit Board Layout DISCLAIMER OF WARRANTIES LIMITATION OF BUYER’S REMEDIESAppendix B- Typical Wiring Diagrams