Emerson 1F80-0471 specifications Troubleshooting, Reset Operation

Page 8

TROUBLESHOOTING

Reset Operation

Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Note: Be sure to review the installer configuration menu settings.

To reset the programming, clock and configuration settings, press and and the FAN button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.

Symptom

Possible Cause

Corrective Action

 

 

 

 

No Heat/No Cool/No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety inter-

 

 

panel loose or not properly installed.

lock or door switch.

 

4.

Loose connection to thermostat or system.

Tighten connections.

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2.

Furnace Lock-Out Condition. Heat

Many furnaces have safety devices that shut down when

 

 

may also be intermittent.

a lock-out condition occurs. If the heat works intermittently

 

 

 

contact the furnace manufacturer or local HVAC service

 

 

 

person for assistance.

 

3.

Heating system requires service or

Diagnostic: Set SYSTEM Switch to HEAT and raise the

 

 

thermostat requires replacement.

setpoint above room temperature. Within a few seconds the

 

 

 

thermostat should make a soft click sound. This sound usu-

 

 

 

ally indicates the thermostat is operating properly. If the ther-

 

 

 

mostat does not click, try the reset operation listed above. If

 

 

 

the thermostat does not click after being reset contact your

 

 

 

heating and cooling service person or place of purchase for

 

 

 

a replacement. If the thermostat clicks, contact the furnace

 

 

 

manufacturer or a HVAC service person to verify the heating

 

 

 

is operating correctly.

 

 

 

 

No Cool

1.

Cooling system requires service or

Same as diagnostic for No Heat condition except set the

 

 

thermostat requires replacement.

thermostat to COOL and lower the setpoint below the room

 

 

 

temperature. There may be up to a five minute delay before

 

 

 

the thermostat clicks in Cooling.

 

 

 

 

Heat, Cool or Fan

1.

Possible short in wiring.

Check each wire connection to verify they are not shorted or

Runs Constantly

2.

Possible short in thermostat.

touching together. No bare wire should stick out from under

 

3.

Possible short in heat/cool/fan system.

terminal block. Try resetting the thermostat as described

 

4.

FAN Switch set to Fan ON.

above. If the condition persists the manufacturer of your

 

 

 

system or service person can instruct you on how to test the

 

 

 

Heat/Cool system for correct operation. If the system oper-

 

 

 

ates correctly, replace the thermostat.

 

 

 

 

Thermostat Setting &

1.

Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees. See

Thermostat Thermometer

 

requires adjustment.

Temperature Display Adjustment in the Configuration Menu

Disagree

 

 

section.

 

 

 

 

Furnace (Air Conditioner)

1.

The location of the thermostat and/or

Digital thermostats provide precise control and cycle faster

Cycles Too Fast or Too

 

the size of the Heating System may

than older mechanical models. The system turns on and off

Slow (narrow or wide

 

be influencing the cycle rate.

more frequently but runs for a shorter time so there is no

temperature swing)

 

 

increase in energy use. If you would like an increased cycle

 

 

 

time, choose SL for slow cycle in the Configuration menu,

 

 

 

step 6 (heat), 7 (cool) or 8 (heat pump). If an acceptable

 

 

 

cycle rate is not achieved, contact a local HVAC service

 

 

 

person for additional suggestions.

 

 

 

 

White-Rodgers is a division of Emerson Electric Co.

The Emerson logo is a trademark and service mark of Emerson Electric Co.

HOMEOWNER HELP LINE: 1-800-284-2925

www.white-rodgers.com

Image 8
Contents Specifications ApplicationsSave these instructions for future use IndexWiring Connections Programming and Configuration Items Thermostat Quick ReferenceHome Screen Description INSTALLER/CONFIGURATION Menu INSTALLER/CONFIGURATION MenuINSTALLER/CONFIGURATION Menu Operating Your Thermostat Worksheet for Re-Programming 5/2 Day and 5+1+1 Day Program Energy Saving Factory Pre-ProgramPlanning Your Program Important Troubleshooting Reset OperationDescripción AplicacionesEspecificaciones Instalación Conexiones EléctricasElementos de programación y configuración Guía DE Referencia Rápida DEL TermostatoDescripción de la pantalla principal Menú INSTALADOR/DE Configuración ParaModo Cómo Usar EL Termostato ¡IMPORTANTEPre-programación de ahorro de energía de fábrica Planificación del programa ImportantePeríodo SábSolución DE Problemas Operación de reajuste
Related manuals
Manual 2 pages 30.65 Kb

1F80-0471, 1F80-0471 specifications

The Emerson 1F86-0471, 1F80-0471, 1F86ST-0471, and 1F80ST-0471 are advanced smart thermostats designed to enhance home comfort while promoting energy efficiency. These models stand out for their user-friendly interfaces, robust features, and cutting-edge technologies, making them ideal choices for homeowners looking to optimize their heating and cooling systems.

One of the primary features of the Emerson thermostats is their compatibility with a wide range of HVAC systems, including conventional and heat pump systems. This versatility allows homeowners to upgrade their thermostats without having to change their existing heating and cooling setups. The smart thermostats also support multi-stage heating and cooling, granting users precise control over their home environments.

Equipped with Wi-Fi connectivity, the Emerson thermostats enable remote access via mobile apps. Homeowners can conveniently adjust their home's temperature, set schedules, and monitor energy usage from virtually anywhere. This remote functionality not only enhances comfort but also helps in reducing energy bills by allowing users to make real-time adjustments based on their daily routines.

Another noteworthy characteristic is the inclusion of a seven-day programming feature. Users can create custom heating and cooling schedules that suit their lifestyles, ensuring that their homes are always at the desired temperature when they need it. The thermostats also incorporate smart alerts, notifying users about filter changes and system maintenance requirements, which can help prolong the life of the HVAC system.

The Emerson models utilize adaptive intelligence, which learns user preferences over time and automatically adjusts settings to promote energy savings without sacrificing comfort. This technology allows the thermostat to optimize settings based on historical data, ensuring efficient operation.

Additionally, the user interface on these models is intuitive, with a clear LCD display that makes programming and adjustments straightforward. For those who prefer voice control, integration with popular smart home systems like Amazon Alexa and Google Assistant offers an added layer of convenience.

In summary, the Emerson 1F86-0471, 1F80-0471, 1F86ST-0471, and 1F80ST-0471 smart thermostats combine advanced technology with user-friendly features. Their adaptability, remote control capabilities, and efficient programming make them an excellent investment for maintaining a comfortable and energy-efficient home. With their focus on user experience and functionality, these thermostats represent a significant advancement in home climate control solutions.