INSTALLATION
Install the appliance in the room to be
1)Check the installation of the air filter.
2)Install the exhaust hose connector (2, Fig. D) on the warm air outlet (at the back of the appliance), and turn it clockwise.
3)Connect the exhaust hose (1,Fig. D) to the connector turning it counterclockwise and pull the hose to the desired length.
4)Place the second connector (2, Fig. D) on the opposite end of the hose, turning it counterclockwise.
5)Drill a 4” diameter hole into a wall or install the plastic window panel in the window
and adjust it’s length.
6)Install nozzle fitting (3, Fig. D) into the hole in the wall or attach the nozzle fitting (3, Fig. D) to the plastic window panel with four screws.
7)Connect the exhaust hose connector (2, Fig. D) into the nozzle fitting (3, Fig. D).
8)The cover (4, Fig. D) needs to be installed on the nozzle fitting (3, Fig. D) when the appliance is not used.
For ceiling installation make sure there is adequate ventilation and airflow. The exhaust hose must clear the surrounding insulation.
The air conditioner can now be connected to a 110V/60 Hz dedicated 15 amp socket. You are advised not to use an extension cord. If, however, this is unavoidable, the cord must be 14 gauge, grounded at both ends and not be more than 30 feet long.
**Note: Make sure the unit is plugged into a “dedicated” circuit; this unit requires 12 amps of power every time it is started.
5