CONTROL PANEL
14 | 5 | 15 |
| ||
6 |
| 4 |
7 |
| 13 |
| 9 | |
8 |
| |
| 10 | |
1 |
| |
|
| |
2 |
| 3 |
| 11 | 12 |
4. Water Removal Indicators |
* Pump ON |
Pump setting button is selected when using the |
automatic pump feature with included 18 ft. hose |
To select the pump as your water removal option, |
press the pump button (4). When the pump |
indicator (13) is on, the pump will automatically |
remove the water in the bucket only when the |
bucket is full. The pump light must be on at all time |
to use this function. It will only turn on for a period |
of 30 seconds to remove the water. The pump will |
turn off after 30 seconds and not turn on again until |
the bucket is full again. It is normal for a small |
amount of water to remain in the bucket after the |
pump has operated; this is to protect the pump. |
The pump button should be off at all times except |
when the user chooses this as their option to remove |
collected water (See Page 7, Option 3). The pump |
5. Low Room Humidity Indicator
Low room humidity indicator (7) will light when
unit detects low humidity levels.
Dehumidifier pint capacity is defined as how much moisture it can draw out of the air in a 24 hour period in 80 degrees F and 60% Relative Humidity. Once humidity begins to drop from 60%, the amount of moisture in the air begins to fall, which will result in less water in your bucket.
NOTE: THIS UNIT IS EQUIPPED WITH A POWER FAILURE AUTO RESTART. IN THE EVENT OF A POWER FAILURE THIS UNIT WILL TURN BACK ON TO ITS LAST SETTING ONCE POWER IS RESTORED.
1. Power ON/OFF
Pressing button (1) will turn the machine on. Pushing again will turn the machine off. Please note unit may run on and off depending on humidity levels and programmed humidity set.
2.Select Operating Mode * Auto Mode
When the unit is turned on for the first time or by cycling through the settings using the setting button
(3) until auto indicator (9) is lit, operation begins in auto mode. "50" will appear in the display (5) and the auto indicator (9) will light up. In this setting, humidity level and fan speed is adjusted for optimum comfort (50%) with no manual adjustment needed. If a humidity adjustment arrow (15) or fan speed button (2) is pressed while in auto mode, the unit will switch to humidity mode automatically.
* Humidity Mode
To set desired humidity level when not in auto mode, push setting button (3) until humidity indicator (10) is lit. The humidity levels will adjust in increments of 5% beginning at a low of 35% and reaching a maximum of 70%. Humidity will show in the display when adjusting humidity level. To adjust humidity level up or down, press humidity adjustment arrows (15) until desired humidity level is reached.
* Cycle Run Time
To set Cycle Run Time, push setting button (3) until cycle run time indicator (11) is lit. In this setting, the unit will run for either 3, 6, or 12 hours, then shut off for 3, 6, or 12 hours, then turn on
again in the same cycle. To program Cycle Run Time, the cycle run time indicator (11) must be lit. Cycle Run Time can be adjusted by pushing the timer adjustment arrows (14) up or down to set operating time for 3, 6, or 12 hours. The cycle timer function will continue until you change the setting or turn the unit power off. In this setting, the unit will operate on the last humidity setting programmed. During cycle run time operation, compressor and fan may shut off depending on programmed humidity level.
* Continuous Mode
To set the unit into continuous mode, push setting button (3) until continuous indicator (12) is lit. Continuous mode will run the compressor and fan continuously until it is powered off or until another setting is inputted. When continuous mode is programmed, “Co” will be displayed. Fan speed can be adjusted in this mode.
3. Select Your Fan Speed
By pressing fan speed button (2), fan speed will change. The indicator (8) of selected fan speed will light (High or Low). In Auto Mode, fan speed will adjust the fan speed automatically depending how close the room humidity is to 50%. For example, if the room is 70%, the unit will need to pull in air quickly, so it will turn on high. Once the room reaches 55%, the unit will slow the amount of air flow and turn the fan on low. Fan Speed can be adjusted in all settings except for auto mode.
option should only be selected when there is a ¼” |
hose properly installed in the pump drain location. |
If the pump button is pressed when using other |
disposal options, E3 (Error message – See page 10) |
will be displayed. If other disposal options are |
needed, push the pump button again to turn off the |
pump function. |
* Bucket Full Indicator |
When the collection bucket is full, bucket full |
indicator (6) will light. The unit will not run with the |
bucket full. Dispose of water and replace bucket |
properly. |