| C-240 0 | | | | |
| Note to specifiers: Words in parentheses indicate frequently specified and highly recommended options. |
PART I – GENERAL | 1.08 | Warranty | 2.04 | Locks |
1.01 | Section Includes | A. | Standard manufacturer’sTENYEAR warranty | A. | Locks shall engage the right-hand vertical track |
A. | Sectional overhead doors [manually] [motor] operated | | against cracking,splitting or deterioration due to | | and utilize [an interior side lock] [standard size |
| with accessories and components. | | rust-through. | | rim cylinder]. |
1.02 | Related Work | PART I I – PRODUCTS | 2.05 | Weatherstripping |
A. | Opening preparation, miscellaneous or structural | 2.01 | Manufacturer | A. | Doors shall be equipped with vinyl bulb shaped astragal |
| steel work, access panels finish or field painting are in | A. | Wayne-Dalton or approved equal Model C-2400 | | as standard on the bottom section.Optional joint,top |
| the scope of work of other trades and divisions of | | insulated sectional overhead doors of steel | | head,and jamb seals are available. |
| these specifications. | | construction complete as specified in this section and | 2.06 | Glazing |
1.03 | Reference Standards | | as manufactured by Wayne-Dalton Corp. |
2.02 | Materials | A. | Optional. |
A. | ANSI/DASMA 102 – American National | 2.07 | Windload |
| Standards Institute [A216.1] Specifications for | A. | Door Sections:Shall be of roll formed steel type with |
| sectional overhead doors published by Door & | | box shaped 20 ga. [intermediate and end stile | A. | Windload – per DASMA 102-2003 and as required by |
| Access Systems Manufacturers Association | | construction] and calculated materials“R”- value of | | local codes. |
B. | International in bulletin 102-1990. | | 7.60 [optional] in accordance with industry guidelines. | PART III – EXECUTION |
ASTM A123 – Zinc [hot-dipped galvanized] | | 1. Exterior Skin:Structural quality,hot-dipped |
C. | coatings on iron and steel products. | | galvanized steel, with [embossed stucco] [smooth] | 3.01 | Installation |
ASTM A216 – Specifications for sectional | | finish nominal 24 ga. with baked-on polyester | A. | General: |
D. | overhead type doors. | | primer and [white] [brown] polyester finish coats | | 1. Install doors in accordance with manufacturer’s |
ASTM A229 – Steel wire, oil-tempered for | | with [smooth][non-repeating random stucco | | instructions and standards.Installation shall be by an |
E. | mechanical springs. | | texture] and 4 deep pinstripes. | | authorizedWayne-Dalton representative. |
ASTM A-653-94– Steel sheet, zinc-coated | | 2. Insulation:Cavity shall be filled with laid-in-place | | 2. Verify that existing conditions are ready to receive |
| [galvanized] by the hot-dipped process, | | [polyurethane] [expanded polystyrene] and | | sectional overhead door work. |
F. | commercial quality. | | covered with [vinyl] [ 0.015” minimum embossed | | 3. Beginning of sectional overhead door work means |
ASTM E330 – Structural performance of | B. | steel] held in place with polymer clips. | B. | acceptance of existing conditions. |
| exterior windows,curtain walls,and doors by | Track:Track design shall be [standard lift] [high lift] | Install door complete with necessary hardware,jamb |
G. | uniform static air pressure difference. | | [vertical lift] [low headroom].Vertical mounting angles | | and head mold strips,anchors,inserts,hangers,and |
ASTM E413-87– Sound transmission class. | | shall be hot-dipped galvanized.Track size shall be [2"] | | equipment supports in accordance with final shop |
H. | Acoustical performance value = 23 per. J. | | [3"].Vertical track shall be graduated to provide wedge | | drawings,manufacturer’s instructions,and as specified |
ASTM E1332-90– Outdoor-indoor | | type weathertight closing with continuous angle | C. | herein. |
| transmission class. | | mounting for [steel] [wood] jambs,and shall be fully | Fit,align and adjust sectional overhead door assemblies |
| Acoustical performance value = 19. | | adjustable to seal door at jambs [bracket mount for | D. | level and plumb for smooth operation. |
1.04 | Quality Assurance | | wood]. Horizontal track shall be reinforced with | Upon completion of final installation,lubricate,test and |
| continuous angle of adequate length and gauge to | | adjust doors to operate easily,free from warp,twist or |
A. | Sectional overhead doors and all accessories and | | minimize deflection. | | distortion and fitting for entire perimeter. |
| components required for complete and secure | Note: Horizontal track applies to standard lift,high lift,low | Note: Architect may consider providing a schedule when |
| installations shall be manufactured as a system from | | headroom and follow-the-roof designs only. | | more than one sectional overhead door or opening |
| one manufacturer. | C. Hardware:Hinge and RollerAssembly: | | type is required. |
1.05 | Systems Description | | 1. Hinges and brackets shall be made from hot- | 3.02 | Materials (See note above.) |
| dipped,galvanized steel. |
A. | Sectional Overhead Door:Type: | | 2. Track rollers shall be case-hardened inner | | |
B. | Model C-2400 | | steel races with 10-ball [2"] [3"] rollers. | | |
Mounting:Continuous angle mounting for [steel] | | 3. All factory authorized attachments shall be | | |
C. | [wood] jambs [bracket mounting for wood jambs] | D. | made at locations indicated. | | |
Operation:[manual push-up] [chain hoist] [motor] | Counterbalance: | | |
D. | [motor with chain hoist] | | 1. Springs shall be torsion type,low-stress,helical | | |
Material:Galvanized steel with polyester finish paint | | wound,oil-tempered spring wire to provide | | |
E. | Insulation:Optional [polystyrene] [polyurethane] | | minimum [10,000 standard] [25,000] [50,000] | | |
1.06 | Submittals | | [100,000] cycles of use,on continuous steel [solid]. | | |
| 2. Spring fittings and drums made of die cast,high | | |
A. | Shop Drawings:Clearly indicate the following: | | strength aluminum. | | |
| 1. Design and installation details to withstand | | 3. Pre-formed galvanized steel aircraft cable shall | | |
| standard windload. | | provide a minimum of a 5:1 safety factor. | | |
| 2. All details required for complete operation | 2.03 | Operation | | |
| and installation. | | |
| 3. Hardware locations. | A. | Operation shall be [manual push-up] [chain hoist] | | |
| 4. Type of metal and finish for door sections. | | [motor] [motor with chain hoist]. | | |
| 5. Finish for miscellaneous components and | Note: Manufacturer does not recommend chain hoists or | | |
B. | accessories. | | jack shaft operators on the following track applications. | | |
Product Data:Indicating manufacturer’s product | | • 15" radius standard lift with roof pitch | | |
| data,and installation instructions. | | less than 2:12 | | |
1.07 | Delivery, Handling, Storage | | • Hi-lift less than 24" | | |
| • Hi-lift between 12" – 23" with roof pitch | | |
A. | Deliver products in manufacturer’s original | | less than 1:12 | | |
B. | containers,dry,undamaged,seals and labels intact. | | • Low headroom track | | |
Store and protect products in accordance with | | Special chain hoist assemblies (using a trolley rail) | | |
| manufacturer’s recommendations. | | are available for the above track systems. | | |