THERMOTITE® | 800C SERIES |
Note to specifiers: Words in brackets indicate frequently specified and highly recommended options. |
PART I – GENERAL | | | | | bottom bar to [stop and reverse] the door |
1.01 | Work Included | PART I I – PRODUCTS | | 2.08 | when it contacts an object during the closing cycle. |
| A. | The opening will be equipped withWayne-Dalton | | Weatherstripping |
| | 800C Series rolling doors. | 2.01 | Curtain | | A. | Doors will include bottom astragal,surface guide |
1.02 | Related Work | A. | Curtain will be composed of interlocking #14 flat slats | | weatherstrip,and internal hood baffle weatherstrip. |
| [22,20,18 gauge galvanized steel] [16 B&S aluminum] | | Optional lintel brush weatherstrip available. |
| A. | Opening preparation,miscellaneous or structural | | [22,20 stainless steel] slats with [24 gauge][22 gauge | 2.09 | Locking |
| | metal work,access panels,finish or field painting, | | B&S aluminum] back slats,roll-formed perASTM |
| | field electrical wiring,wire,conduit,fuses,and | | standards. The area between the #14 exterior slat | A. | [Manual lift-up doors will have interior slide-bolts |
| | disconnect switches are in the Scope ofWork of | | and the back slat will be filled by polyurethane | | suitable for padlocks by others.] [Chain-hoist door |
| | other divisions or trades. | | insulation,R-value of 6.7 (U = 0.15). Curtain designed | | will have chain keepers suitable for padlocks by |
1.03 | Reference Standards | | to withstand a 20 PSF windload. Ends of | | others.] [Electric-motor operation doors will lock |
| alternate/continuous slats will be fitted with metal | | through the operator gearing.] [Cylinder locks can |
| A. | ANSI/DASMA 203 – American National | B. | endlocks/windlocks. | | | be provided with the doors.] |
Standards | Institute Specifications for non-rated fire rolling doors | Bottom Bar will consist of two equal steel | Note: When specifying locks on electric-motor operated |
| | | [stainless steel] [aluminum] angles, .121" minimum | | doors,electric interlocks should also be specified to |
| | published by Door &Access Systems Manufacturers | | thickness,to stiffen curtain,with astragal. When | | prevent operation when lock bolts are engaged in the |
| B. | Association International. | | required for additional security,provide [slide bolts] | | guides,thus preventing damage to the curtain |
ings | ASTM A123 – Zinc [hot-dipped galvanized] coat- | | [cylinder locks] on the bottom bar operable from | | and/or operator. |
C. | on iron and steel products. | 2.02 | [coil side] [both sides]. | | 2.10 | Windload |
| ASTM A229 – Steel wire,oil-tempered for | Guides | | A. | Windload – minimum 20 psf per DASMA 102-2003 |
| D | mechanical springs. | A. | Guides will be roll-formed steel channel bolted to | | and as required by local codes. |
| ASTM A-653-94– Steel sheet,zinc-coated | | angle or structural grade,three angle assembly of | PART III – EXECUTION |
| | [galvanized] by the hot-dipped process, | | steel [stainless steel] [aluminum] to form a slot of |
| E. | commercial quality. | | sufficient depth to retain curtains in guides to achieve | 3.01 | Installation |
| ASTM E330 – Structural performance of exterior | | 20 PSF windload standard. Guides may be provided | A. | General: |
| | windows,curtain walls,and doors by uniform static air | | with integral windlock bars and removable bottom | | 1. Install doors in accordance with manufacturer’s |
| F. | pressure difference. | | bar stops. | | | instructions and standards. Installation shall be by |
| ASTM E413-87– Sound transmission class | 2.03 | Brackets | | | an authorizedWayne-Dalton representative. |
| | acoustical performance value = 22. | | | 2. Verify that existing conditions are ready to receive |
| | | A. | Brackets will be of 3/16” [1/4"] minimum thick steel | | rolling door work. |
1.04 | Quality Assurance | | plates,with permanently sealed ball bearings. Designed | | 3. Beginning of rolling door work means acceptance |
| to enclose ends of coil and provide support for | B. | of existing conditions. |
| A. | Rolling doors and all accessories and components | | counterbalance pipe at each end. | Install door complete with necessary hardware,jamb |
| | required for complete and secure installations shall be | 2.04 | Counterbalance | | | and head mold strips,anchors,inserts,hangers,and |
| | manufactured as a system from one manufacturer. | | | equipment supports in accordance with final shop |
1.05 | Systems Description | A. | Curtain to be coiled on a pipe of sufficient size to | | drawings,manufacturer’s instructions,and as specified |
| carry door load with deflection not to exceed .033" | C. | herein. |
| A. | Rolling Door:Type: | | per foot of door span and to be correctly balanced by | Fit,align and adjust rolling door assemblies level and |
| B. | Model 800C | | helical springs,oil tempered torsion type. Cast iron | D. | plumb for smooth operation. |
| Mounting:[steel] [wood] [masonry] jambs | | barrel plugs will be used to anchor springs to tension | Upon completion of final installation,lubricate,test and |
| C. | Operation:[manual push-up] [crank] [chain hoist] | | shaft and pipe. | | | adjust doors to operate easily,free from warp,twist or |
| D. | [motor] [motor with chain hoist] | 2.05 | Hood | | | distortion and fitting for entire perimeter. |
| Material:Galvanized steel with polyester finish paint | | Note: Architect may consider providing a schedule when |
1.06 | Submittals | A. | Hood will be minimum 24-gauge [aluminum, | | more than one rolling door or opening type is |
| 22 gauge B&S] [galvanized] [stainless steel] sheet | | required. |
| A. | Shop Drawings:Clearly indicate the following: | | metal,flanged at top for attachment to header and | | |
| | 1. Design and installation details to withstand | | flanged at bottom to provide longitudinal stiffness. | | |
| | standard windload. | | Hood will enclose curtain coil and counterbalance | | |
| | 2. All details required for complete operation | | mechanism. A flexible hood baffle is included. | | |
| | and installation. | 2.06 | Finish | | | |
| | 3. Hardware locations. | | | |
| | 4. Type of metal and finish for door sections. | A. | Shop coat of rust inhibitive primer on non-galvanized | | |
| | 5. Finish for miscellaneous components and | | surfaces and operating mechanisms. Guides and | | |
| B. | accessories. | | bracket plates will be coated with a flat black prime | | |
| Product Data:Indicating manufacturer’s product | | paint. Aluminum finish to be [mill] [204R1 clear | | |
| | data,and installation instructions. | | anodized] [bronze anodized]. Stainless steel finish | | |
1.07 | Delivery, Handling, Storage | | available. Curtain color will be [white] [blue] [gray] | | |
| [beige] [brown] (white,blue,beige,brown only | | |
| A. | Deliver products in manufacturer’s original | | available as 22 gauge). Powder coating is available in | | |
| B. | containers,dry,undamaged,seals and labels intact. | | 180 colors. | | | |
| Store and protect products in accordance with | 2.07 | Operation | | | |
| | manufacturer’s recommendations. | | | |
1.08 | Warranty | A. | Door will be operated by means of [manual,lift-up] | | |
| [chain hoist with gear drive reduction] [awning crank] | | |
| A. | Standard manufacturer’s one year warranty against | | [wall crank box] [motor operation]. Optional | | |
| | defects in material and workmanship. | | [electrical] [pneumatic] sensing edge to be attached to | | |