Videx Intercom Instructions and User Manual for VX800 Series

Page 1

 

Art.VX800N

 

Installation Instructions

MODELS:

 

VX800N-2

Module 2 Relay

VX800N-2L

Module 2 Relay plus panel illumination

VX800N/F

Stand alone unit 2 Relay. Flush mounting

VX800N/S

Stand alone unit 2 Relay. Surface mounting

VX800N-3

3 Relay

VX800N-3L

3 Relay plus panel illumination

FEATURES

￿Access control system with 2 codes and 2 Relay outputs (3 codes, 3 relays on VX800N-3.. version).

￿Engineer’s code to enter into the “Programming Menu” ( from 4 to 8 digits).

￿Programming of the activation time of each relay from 1 up to 99 seconds or latching.

￿Possibility to activate relay 1 by shorting terminal ”SW1” to GND and relay 2 by shorting terminal “SW2” to GND. Both relays will operate for the programmed time ( this feature is not available on VX800N-3 version).

￿Keypad gives an acoustic (buzzer) signal during the entering of codes and a continuous melody for 4 or more seconds, according to the number of mistakes (self protection).

￿Keypad includes panel illumination (VX800N-..L only) and 2 LED’s to show the following:

￿Correct relay code (green LED on for 2 seconds).

￿Red LED to indicate when in the “programming menu”.

￿Contacts of the relays are available ( N.O and N.C) with 5A max 24Vac/dc.

￿Power requirements: 12/24V AC/DC, 2VA.

￿Working temperature: -10 +50°C

OPERATION

To use the system, type in the programmed code and press “ENTER” , the green LED will illuminate and the relay will operate for the programmed time.To cancel remain open time, type in the same code and press “CLEAR”. If a wrong code is entered, a continuous melody will sound for 4 or more seconds, according to the number of mistakes.

INITIALIZATION

When the installation is concluded and carried out according to the wiring diagram, power up the system and program it by following the “VX800 PROGRAMMING” Flow Chart.

GENERAL DIRECTIONS FOR INSTALLATION

In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment, strictly keeping to the items indicated on each schematic and follow these General Directions for Installation:

￿The system must be installed according to national rules in force, in any case the running of cables of any intercom unit must be carried out separately from the mains;

￿All multipair cables should be compliant to CW1308 specification (0.5mm twisted pair telephone cable.

￿Cables for speech line and service should have a max resistance of 10￿

￿Lock release wires should be doubled up (Lock release wires and power supply wires should have a max resistance of 3￿);

￿The cable sizes above can be used for distances up to 50m. On distances above 50m the cable sizes should be increased to keep the overall resistance of the cable below the RESISTANCES indicated above;

￿Double check the connections before power up;

￿Power up the system then check all functions.

LOCK RELEASE BACK EMF PROTECTION

A capacitor must be fitted across the terminals on AC lock release (Fig.1A) and a diode must be fitted across the terminals on a DC lock release (Fig.1B) to suppress back EMF voltages.

Connect the components to the lock releases as shown in figures.

Fig.1A

Fig.1B

BUZZER BACK EMF

When using intercoms with buzzer call (Art.924/926, SMART1/2, 3101/2, 3001/2 and 3021/2) add one 0,1uF capacitor between terminals 6 and 3.

If help is required for installing or operating this unit please contact our technical department on +39 0734 631669 (all countries) or +44 0191 224 3174 (UK).

Factory - Office

VIDEX ELECTRONICS S.p.A. Via del lavoro,1 63020 MONTEGIBERTO (AP) - ITALY Phone: (+39) 0734 - 631669 Fax: (+39) 0734 - 632475 www.videx.it e-mail: info@videx.it

Northern UK Office

VIDEX LTD Unit 4-7 Chillingam Industrial Estate Chapman Street NEWCASTLE UPON TYNE Ne6 2XX

Phone: (+44) 0870 3001240 Fax: (+44) 0191 - 2241559 www.videx-security.com

PROGRAMMING(refer also to flow chart)

￿ Enter “ENGINEER’S CODE”: first time type six times “1” (111111 factory

preset) and press ENTER (The red LED will illuminate).

￿ Confirm “ENGINEER’S CODE” (typing again the same) or type the new

code (4 to 8 digits) then press ENTER (Melody). Pressing twice the

Press Enter (Red LED will be ON)

Press Enter (Melody)

Press Enter (Melody)

Press Enter (Melody)

Press Enter (Melody)

Press Enter (Melody)

Press Enter (Melody)

Press Enter (Melody)

ENTER

“ENGINEER’S CODE”

CONFIRM OR CHANGE “ENGINEER’S CODE”

ENTER

“ACCESS 1 CODE”

ENTER

“ACCESS 1 TIME”

ENTER

“ACCESS 2 CODE”

ENTER

“ACCESS 2 TIME”

ENTER

“ACCESS 3 CODE”

ENTER

“ACCESS 3 TIME”

SYSTEM READY TO

USE

FIRST TIME SIX TIMES 1 “111111” FACTORY PRESET

TYPE AGAIN SIX TIMES “1” OR THE NEW ENGINEER’S CODE 4 TO 8 DIGITS

CODE TO ENABLE RELAY 1

4 TO 8 DIGITS

TWO DIGITS (01 TO 99) I.E. 05=5 SECONDS 00= REMAIN OPEN

CODE TO ENABLE RELAY 2

4 TO 8 DIGITS

TWO DIGITS (01 TO 99)

ONLY 800-3 VERSION

ONLY 800-3 VERSION

RED LED WILL BE OFF

ENTER button without changing the “ENGINEER’S CODE”, will exit

from the programming.

￿ Enter the code (4 to 8 digits) to enable “RELAY 1” (ACCESS 1) or re-

enter the existing code then press ENTER (Melody).

￿ Enter the “RELAY 1” operation time (2 digits 01 to 99 I.E. 05=5 seconds,

00= remain open time) or re-enter the existing time then press ENTER

(Melody).

￿ Enter the code (4 to 8 digits) to enable “RELAY 2” (ACCESS 2) or re-

enter the existing code then press ENTER (Melody).

￿ Enter the “RELAY 2” operation time (2 digits 01 to 99 I.E. 05=5 seconds,

00= remain open time) or re-enter the existing time then press ENTER

(Melody).

￿ Enter the code (4 to 8 digits) to enable “RELAY 3” (ACCESS 3 only for 3

relay models) or re-enter the existing code then press ENTER (Melody).

￿ Enter the “RELAY 3” (only for 3 relay models) operation time (2 digits 01

to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing

time then press ENTER (Melody).

￿ The system is ready to use (the red LED will be off).

INSTRUCTION TO RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE

￿Turn off power to code lock.

￿Keep “ENTER” button pressed while turning back on the power to the code lock.

￿Release “ENTER” button.

￿The master code is now set at factory engineer’s code “111111” (six times “1”).

￿Proceed with programming for a new system.

NOTES

￿To switch off any relay while operating, type in the relevant code then press the “CLEAR” button.

￿To operate relays together, set the same code for each relay.

￿If a wrong code is entered, the system will lock out for 5 seconds which will increase each time a wrong code is entered. The system will operate only when the correct code is entered.

Image 1
Contents Models FeaturesOperation InitializationRE-PROGRAMMING Guide

VX800N/F, VX800N-2, VX800N-2L specifications

The Videx VX800N series, which includes models VX800N-2L, VX800N/F, and VX800N-2, is a comprehensive range of intercom systems designed for robust communication in residential and commercial buildings. These advanced intercoms are celebrated for their exceptional performance, adaptability, and innovative features, making them an ideal choice for modern security solutions.

One of the standout characteristics of the VX800N series is its utilization of advanced IP technology. This enables seamless integration with existing network infrastructures, allowing for easy installation and operation. The intercom systems support Power over Ethernet (PoE), simplifying the wiring requirements while ensuring reliable power delivery and minimizing installation costs.

The VX800N-2L model features a dual-line display, providing essential information at a glance. This innovative feature enhances user interaction by displaying caller information, making it easier for users to identify who is at the door before deciding to engage. With intuitive navigation buttons, the VX800N-2L ensures users can effortlessly access all functions.

The VX800N/F model is particularly noteworthy for its extensive multimedia capabilities. It supports video streaming, enabling clear visual communication between users and visitors. This function significantly enhances security by allowing users to see and interact with visitors before granting access, thus providing an added layer of protection.

The VX800N-2 variant features dual-channel communication, allowing for simultaneous two-way audio conversation, which is critical in high-traffic environments. This functionality is complemented by high-quality speakers and microphones, delivering crystal-clear audio for effective communication.

All models in the VX800N series are built to withstand various environmental conditions, ensuring longevity and performance regardless of outdoor exposure. The robust construction and weatherproof design make them suitable for outdoor installations, providing versatile options for different settings.

The integration with other security systems is another key advantage of the Videx VX800N series. The intercoms can be connected to access control systems, CCTV, and alarm systems, facilitating a comprehensive security network that enhances the overall safety and convenience for users.

In conclusion, the Videx VX800N-2L, VX800N/F, and VX800N-2 intercom systems embody cutting-edge technology, reliable performance, and user-friendly design. Their advanced features, such as dual-line displays, multimedia capabilities, and dual-channel communication, make them a top choice for enhancing communication and security in a variety of applications. Whether for residential or commercial use, the VX800N series stands out as an exemplary solution for modern intercom needs.