BRK electronic EL52W-2 user manual Escape Ladder on Windowsills That are, Dimension a

Page 1

 

USER’S MANUAL

TO WORK PROPERLY IN A FIRE EMERGENCY, THIS LADDER MUST:

 

 

Be Stored Where It Is Easy To Reach Quickly...

 

 

 

 

Do not store the ladder on another floor of your home. If you have more than one second-floor room requiring

NYLON/STEEL 2-STORY

an alternate means of escape, put a fire ladder in each room. Store the ladder where it can be immediately

accessed--near the window, under a bed, or in the front part of a closet.

 

FIRE ESCAPE LADDER

Make sure nothing blocks you from reaching the ladder. In a fire you have limited time to react and take action.

Store the ladder in its original box to keep it from becoming tangled.

 

MODEL EL52W-2

 

Be Used On A Suitable Window...

 

 

This nylon/steel Fire Escape Ladder is easy to use, and

This ladder is intended for use in windows that are structurally safe for the intended load.

The ladder must be used from the correct height, and there should be no obstructions along the ladder path to

provides a reliable means of escape through a second

the ground.

 

 

floor window during a home fire.

 

 

This ladder is intended only for second-floor windows no higher than 16 feet (4.9 meters) from the ground.

 

 

FEATURES AND BENEFITS

The windowsill must be no narrower than 6 inches (15 cm) and no wider than 13 inches (33 cm).

The windowsill must be in good condition (no rotted wood, loose boards, etc.).

 

For use in two-story homes

The window must open easily and completely. Storm windows, screens or other types of multi-track windows

Strong nylon construction

can make it difficult to use this ladder in an emergency.

 

 

The window should not be blocked by furniture or security devices like grilles or bars.

 

Fully assembled, ready to use

 

For details on choosing a suitable window, see the “Choosing A Window” section of this manual.

Slip-resistant epoxy coated rungs

Be Properly Secured To The Windowsill Before You Start Climbing Down...

Large hooks secure easily to windowsills

To properly support your weight and provide the needed stability while you climb down, the ladder must be

Steel rung stabilizers on all rungs

properly attached to the windowsill. Make sure the sill hooks rest securely on the windowsill.

Make sure the folding crosspiece between the sill hooks is straight, and the straps do not tangle as you lower

Ladder complies with the ASTM Standard F 2175-02

the ladder out of the window.

 

 

375 lb. (170 kg) Ladder load rating

 

 

Choosing A Window

 

 

Ladder is 14 feet (4.3 meters) in length.

 

 

 

 

 

 

 

 

2. The window should be at least 20 inches (51 cm)

 

 

This escape ladder is not intended for use from

wide and 32 inches (81 cm) high to give you

 

 

second floor windows directly above first floor

enough clearance to exit safely.

Read instructions for use immediately upon purchase.

windows. The rung stabilizers could break a first

The windowsill width should be between a

floor window and cause injury.

Close doors before opening any windows to prevent fire from being drawn into the room.

 

minimum of 6 inches (15 cm) and a maximum

 

of 13 inches (33 cm). Measure windowsill from

Keep body close to ladder.

 

 

outside to inside. DO NOT USE THIS FIRE

Unless absolutely necessary, do not carry a child when using this ladder.

 

ESCAPE LADDER ON WINDOWSILLS THAT ARE

Do not carry pets or miscellaneous objects when using this ladder.

Do not use from a

TOO LARGE OR TOO SMALL FOR THE HOOKS.

 

 

Instruct family members to use this portable escape ladder only when the primary escape path

 

 

second floor window

 

 

 

(that is, the main exit) is blocked or unsafe to use.

 

 

 

directly above a first

 

 

This portable escape ladder is not a toy or recreational device. Instruct children that the ladder

 

 

floor window.

 

DIMENSION A:

 

is to be used only in an emergency.

 

 

 

A

The windowsill width

For use only in windows that are structurally safe for the intended load.

 

 

 

should be between

• Not recommended for use with storm windows or other windows that do not open to the

 

 

 

 

a minimum of 6'' (15

 

recommended minimum dimensions [20 inches (51 cm) wide and 32 inches (81 cm) high].

 

 

cm) and a maximum

Do not use above a 2 story height.

 

 

 

 

of 13'' (33 cm).

• Do not attempt to deploy the ladder from windows that are obstructed by furniture, radiators, air conditioning units, or security devices such as grilles or bars (without inside release mechanisms).

• Do not attempt to deploy the ladder into flames.

• Check for outside obstructions such as electric lines, telephone wires, or fences.

Do not attempt to use the ladder if the windowsill does not meet the size range specified.

 

 

 

The windowsill width should be between a minimum of 6 inches (15 cm) and a maximum of

 

3. DO NOT USE ON A DAMAGED OR WEAK

 

13 inches (33 cm).

 

 

 

 

 

WINDOWSILL. Check windowsill for weak, rotted

Always plan and practice drills to ensure that occupants are familiar enough for proper use.

You must test fit this ladder on your chosen

or loose wood, or damage. Consult a contractor

This ladder is intended to supplement (not replace) the more important fire protection principles

escape window before storing it. In a fire

or replace windowsill BEFORE attempting to hook

 

of fire drills, emergency evacuation plans, smoke alarms, fire extinguishers, etc.

 

emergency you will not have time to determine

the fire escape ladder to a damaged windowsill.

This ladder should be periodically inspected for damage, loosening of any items, or significant

whether or not a particular window is suitable,

This ladder is intended for use in windows that

 

deterioration of the materials of construction.

 

and using the ladder on an unsuitable window

are structurally safe for the intended load.

This ladder is designed for use by one person at a time.

 

could result in injury or death.

4. For safest use, there should be a clear path from

 

1. The ladder should be used ONLY from second

Store the ladder in a convenient location near the exit window; for example, under a bed, in a

the window all the way to the ground. BEFORE

floor windows no more than 16 feet (4.9 meters)

 

closet, etc.

 

STORING THE LADDER FOR AN EMERGENCY:

 

 

from the ground.

 

 

 

From outside of your home, check below the

 

 

 

 

 

 

 

 

window for any obstructions. Check for trees,

 

 

 

 

bushes, plants, windows, house fixtures, or any

 

 

 

 

other objects in the direct path below the chosen

 

 

 

 

window.

 

 

 

Use ONLY from second floor

5. Make sure the window you choose opens easily

 

 

 

windows no more than 16 feet

and completely. In an emergency, every minute

 

 

 

(4.9 meters) from the ground.

counts.

© 2008 BRK Brands Europe Ltd

 

 

 

A Jarden Corporation company (NYSE: JAH)

 

 

 

Unit 6, Carter Court, Davy Way, Waterwells Business Park

 

 

 

Quedgeley, Gloucester GL2 2DE United Kingdom

 

 

 

All rights reserved.

M08-0129-003

01/08

 

 

1

 

 

2

Securing the Ladder After Use

How to Use in a Fire Emergency

What Fire Escape Ladders Cannot Do

Limited Warranty

1. Lay the box on the floor with the lid folded open.

 

This fire escape ladder is NOT a means of

BRK Brands, Inc., ("BRK") the maker of First Alert®

 

This fire escape ladder is not a toy or recreational

 

protection against fire. It will not warn or alert

brand products warrants that for a period of six years

 

device. Use it only in a fire emergency.

 

you to a fire or of any other type of emergency.

from the date of purchase, this product will be free

2. Stretch the ladder out on the floor, with the rung

 

 

It is intended to be used as an alternate escape

from defects in material and workmanship. BRK, at

 

 

means in a fire emergency only.

its option, will repair or replace this product or any

standoffs facing up towards you placing the

 

 

 

 

 

component of the product found to be defective

rungs as close as possible next to each other.

It is strongly recommended that children and elderly

This fire escape ladder is NOT intended to be

during the warranty period. Replacement will be

Assemble the rungs into the box keeping the

adults be assisted by an adult if at all possible when

 

the main exit for escape in an emergency.

 

made with a new or remanufactured product or

standoffs facing upward.

using this ladder in a fire emergency.

 

Instruct family members to use the fire escape

 

component. If the product is no longer available,

 

 

 

ladder as a last resort, ONLY when their main

 

 

 

replacement may be made with a similar product of

 

 

 

exit is blocked, not accessible, or unsafe to use.

 

THIS LADDER IS DESIGNED FOR USE BY ONE

 

equal or greater value. This is your exclusive warranty.

 

 

 

 

This fire escape ladder is NOT a toy or recre-

This warranty is valid for the original retail purchaser

 

PERSON AT A TIME.

 

 

ational device. It is intended to be used as a

 

 

 

from the date of initial retail purchase and is not

 

1. Before you open the window, close the door

 

supplemental emergency escape device ONLY.

 

 

transferable. Keep the original sales receipt. Proof of

 

leading out of the room to prevent the fire from

 

Instruct children not to use this fire escape

purchase is required to obtain warranty performance.

 

being drawn into the room.

 

ladder for any reason, except in an emergency.

BRK dealers, service centers, or retail stores selling

 

2. Remove the ladder from the box and unfold sill

DO NOT carry any pets or other objects when

BRK products do not have the right to alter, modify or

 

hooks so the folding crosspiece is straight and

 

using the ladder.

any way change the terms and conditions of this

 

positioned towards you.

Unless absolutely necessary, do not carry a

warranty.

 

 

This warranty does not cover normal wear of parts or

 

 

 

child when using this ladder.

 

 

This portable fire escape ladder does not meet

damage resulting from any of the following: negligent

 

 

use or misuse of the product, use contrary to the

 

 

 

your local codes as a primary means of exit

operating instructions, disassembly, repair or alter-

 

 

 

from multi-family dwellings. It is not intended to

ation by anyone other than BRK or an authorized

3. Use the plastic strap (attached to the last rung)

 

 

replace fire escapes in multi-family residences,

service center. Further, the warranty does not cover

to wrap and secure the rungs. This will minimize

 

 

institutions, or rental properties. This ladder is

Acts of God, such as fire, flood, hurricanes and

the chance of the ladder becoming tangled when

 

 

intended for use as a means of escape from

tornadoes.

you remove it from the box in an emergency.

 

 

residential buildings, and may supplement the

BRK shall not be liable for any incidental or conse-

 

 

 

primary means of exit required by codes and

 

 

 

other local regulations.

quential damages caused by the breach of any

 

 

This fire escape ladder is NOT intended for use

express or implied warranty. Except to the extent

 

 

prohibited by applicable law, any implied warranty

 

 

 

from rooms above a second-floor level. DO NOT

 

 

 

of merchantability or fitness for a particular purpose

 

 

 

use from rooms above a second-floor height.

is limited in duration to the duration of the above

 

 

 

The ladder is 14 feet (4.3 meters) long and is

warranty. Some states, provinces or jurisdictions do

 

 

 

NOT intended for escape from rooms with

not allow the exclusion or limitation of incidental or

 

 

 

windowsills higher than 16 feet (4.9 meters)

consequential damages or limitations on how long

 

 

 

from the ground.

an implied warranty lasts, so the above limitations or

 

 

This fire escape ladder is NOT intended to be

exclusion may not apply to you. This warranty gives

 

 

you specific legal rights, and you may also have

 

 

 

hooked onto gutters, siding, or any other interior

 

 

 

or exterior fixture. It is ONLY intended to be

other rights that vary from state to state or province

 

3. Place the sill hooks firmly over the windowsill and

 

hooked to windowsills.

to province.

 

 

 

 

 

 

 

 

pull the release strap to deploy the ladder.

 

 

 

www.firstalert.eu

4. Place the folded sill hooks on top of the rungs, between the standoffs as shown in the diagram.

 

4. Exit carefully through the

 

window and place your

 

feet on the first rung.

 

Hold onto the window

 

frame until your weight is

 

evenly distributed on the

5. Store the escape ladder in an accessible

ladder. Climb down,

keeping your body close

location. Be sure nothing blocks your access

to the ladder.

to the ladder.

 

First Alert® is a registered trademark of the First Alert Trust.

M08-0129-003 01/08

3

4

Image 1
Contents Escape Ladder on Windowsills That are Dimension aTOO Large or TOO Small for the Hooks Do not USE on a Damaged or Weak

EL52W-2 specifications

The BRK electronic EL52W-2 is a state-of-the-art smoke and carbon monoxide alarm, designed to enhance safety in residential and commercial settings. This device combines advanced technologies with user-friendly features, making it an essential addition to any environment where fire and CO risks are present.

One of the main features of the BRK electronic EL52W-2 is its dual-sensor technology. It utilizes both photoelectric and ionization sensors, which work together to detect different types of smoke more effectively. The photoelectric sensor is particularly adept at identifying smoldering fires, which may produce a significant amount of smoke before bursting into flames. In contrast, the ionization sensor is effective at detecting fast-flaming fires. This dual-sensor approach ensures that the alarm provides a quicker response to various fire scenarios, thereby increasing safety.

The EL52W-2 also boasts a built-in 10-year battery, eliminating the need for frequent battery replacements. This feature is particularly convenient as it reduces user maintenance and ensures the device remains functional for a decade. Additionally, the alarm is equipped with a low-battery chirp to notify users when it’s time to replace the unit or check its functionality.

Another significant technology integrated into the BRK electronic EL52W-2 is the smart home connectivity feature. The device can connect wirelessly to other compatible smoke alarms within the network, allowing for synchronized alerts throughout the property. This feature is especially beneficial in larger homes, as it ensures that when one alarm detects smoke or CO, all interconnected alarms will sound, providing an early warning system that enhances safety.

The sleek and modern design of the EL52W-2 allows it to blend seamlessly into various decor styles, making it both functional and aesthetically pleasing. It comes with a user-friendly test/silence button, providing a simple way for users to check the device’s functionality or silence false alarms.

In conclusion, the BRK electronic EL52W-2 smoke and carbon monoxide alarm offers robust safety features, advanced detection technologies, and user-friendly characteristics, making it a reliable choice for protecting households and businesses alike. With its dual-sensor capability, long-lasting battery, and smart connectivity, it stands out as a sophisticated solution for modern safety needs.