First Alert Model GCO1 user manual Understanding the LIGHT, HORN, and Display Patterns, Led

Page 4

SILENCING THE LOW BATTERY WARNING

This Silence Feature can temporarily quiet the low battery warning “chirp” for up to 8 hours if AC power is present. You can silence the low battery warning “chirp” two ways:

1.Manually: Press the Test/Silence button on the Alarm cover until you see the Green LED flicker, acknowledging the button-press.

2.Using Your Remote Control: Standing no further than 12 feet (3.6 meters) away from the Gas/CO Alarm, aim your IR remote at the Alarm and press the CHANNEL or VOLUME button for at least 3-5 seconds.

The display will flash “SILENCE” for 8 hours while the low battery warning “chirp” silence feature is activated. After 8 hours, the low battery “chirp” will resume. The Alarm will continue to operate as long as AC power is supplied. However, replace the battery as soon as possible, to maintain protection in event of a power outage.

USING THE PEAK CO MEMORY

The CO Memory Feature lets you check the highest level of CO recorded.

To check CO Memory:

1. Press the Display button until the peak CO level is displayed.

To clear CO Memory:

1. While checking CO memory, press or hold the Display button until “CLEAR” is displayed.

2. Press or hold the Display button until the CO Memory is cleared.

NOTE: The highest CO level will be saved, even after a power interruption, until you clear it. DO NOT clear the CO Memory reading if you plan to call someone to investigate a CO problem! Clear the CO Memory reading only after the investigator has checked your home.

UNDERSTANDING THE LIGHT, HORN, AND DISPLAY PATTERNS

Condition

LED

Horn

Display

NORMAL AC POWER

LED is Green.

Silent

All segments

 

 

 

of display are

 

 

 

turned on for

 

 

 

a short time

 

 

 

upon initial

 

 

 

power. Then

 

 

 

the battery level icon is displayed.

BATTERY BACK-UP POWER

LED is Off, flashing Green once every

Silent

All segments of display are turned

 

45 seconds

 

On for a short time upon initial

 

 

 

power. Then the battery level icon

 

 

 

is displayed flashing.

DURING TESTING

LED flashes Red in sync with the

First, the horn pattern for gas alarm

During the simulated

 

horn, simulating an Alarm condition:

(1 beep every second) is issued, and

gas alarm, “GAS” is

 

first gas then CO

then the CO alarm horn pattern

displayed along with

 

 

(4 beeps, pause, 4 beeps) is issued.

a full alarm level.

 

 

 

During the simulated

 

 

 

CO alarm, “CO” is

 

 

 

displayed along with

 

 

 

a full alarm level.

 

 

 

Several ppm CO

 

 

 

levels are also

 

 

 

displayed and

 

 

 

the alarm level is

 

 

 

shown increasing.

LOW OR MISSING BATTERY

Normal

A chirp is issued about every

Battery icon will show

 

 

minute.

an empty icon.

GAS ALARM CONDITION

LED flashes Red in sync with horn

Repeating 1 beep every second

“GAS”, a full level, and “EVACUATE”.

CARBON MONOXIDE ALARM

LED flashes Red in sync with horn

Repeating 4 beeps, pause

“CO” alternating

 

 

 

with the ppm

 

 

 

number, a full level,

 

 

 

and “EVACUATE”.

PRE-ALARM CONDITION

Normal

Normal

“CO” alternating with the ppm number.

CO IS PRESENT

 

 

The level will indicate relative CO

 

 

 

exposure level.

MALFUNCTION

LED flashing Green 3 times in sync

3 rapid chirps every minute

“ERROR” is displayed.

 

with 3 rapid chirps

 

 

LOW BATTERY SILENCE

LED is Green.

Silent

“SILENCE” is displayed.

4

Image 4
Contents Basic Safety Information Table of ContentsInstallation USER’S ManualWhere this Alarm should not be Installed Before YOU Begin InstallationHOW to Install this GAS/CO Alarm Activating the Battery BACK-UPHOW Your Alarm Works If Your GAS/CO Alarm SoundsSilencing the LOW Battery Warning Using the Peak CO MemoryUnderstanding the LIGHT, HORN, and Display Patterns LEDRegular Maintenance Weekly TestingWhat YOU Need to Know about CO Regulatory Information for Explosive GAS/CO Alarms General Limitations of Explosive GAS/CO AlarmsRegulatory Information for Explosive GAS Alarms Regulatory Information for CO AlarmsTroubleshooting Guide Limited WarrantyIf your Alarm does this It means You should How to Obtain Warranty Service

Model GCO1 specifications

The First Alert Model GCO1 is a high-performing carbon monoxide detector that provides essential safety features for homes and businesses. Designed to ensure your well-being, this model is equipped with advanced technologies and characteristics that make it an excellent choice for early detection of harmful CO gas.

One of the primary features of the GCO1 is its electrochemical sensor. This sensor technology is known for its quick response time and accuracy in detecting low levels of carbon monoxide. Traditional detectors may not pick up on minor CO levels until it’s too late, but the GCO1 can alert users earlier, potentially preventing dangerous health issues.

The device is designed with an easy-to-read digital display that continuously shows the level of carbon monoxide present in the air. This feature allows users to monitor CO levels in real-time, providing peace of mind and ensuring prompt action if necessary. The GCO1 also includes a loud 85-decibel alarm that goes off when dangerous levels of carbon monoxide are detected, ensuring that even those with hearing impairments or who are asleep will be alerted.

A significant advantage of the First Alert GCO1 is its battery backup system. In the event of a power outage, the unit continues to function, ensuring uninterrupted protection. The GCO1 typically operates on a 9-volt battery, which is easily replaceable, adding to its user-friendly design. Users can quickly change the battery when prompted by the low battery warning signal.

Moreover, the GCO1 highlights a user-friendly interface with a simple test/silence button. This allows for easy testing of the device to ensure it is working properly while also enabling users to silence false alarms, such as those caused by cooking or other household activities.

The compact design of the First Alert GCO1 allows it to fit seamlessly in any room, whether mounted on a wall or placed on a tabletop. With an attractive finish, it suits various interior decors without standing out as an eyesore.

In summary, the First Alert Model GCO1 combines sophisticated technology with user-centric features, making it a reliable carbon monoxide detector. Its advanced electrochemical sensor, digital display, battery backup, and compact design ensure that families and facilities stay protected from the silent threat of carbon monoxide, providing a significant layer of safety in everyday life.