Hex

0x38

0x30

0x35

0x72

0x62

0x30

0x36

0x37

0x0

D

Example2: Get Brightness from TV-05 , but the Brightness command ID is error

 

and it is NOT in the command table.

 

 

 

 

 

 

 

 

Send (Hex Format)

 

 

 

 

 

 

 

 

 

 

 

Name

Lengt

 

ID

Command

Comman

Value

 

Value

Value

 

CR

 

 

h

 

 

Type

d

1

 

2

3

 

 

 

Hex

0x38

 

0x30

0x67

0XD3

0x30

 

0x30

0x30

 

0x0

 

 

 

 

0x35

 

 

 

 

 

 

 

 

D

Reply (Hex Format)

 

 

 

 

 

 

 

 

 

 

 

Name

Lengt

 

ID

Command

CR

 

 

 

 

 

 

 

 

 

h

 

 

Type

 

 

 

 

 

 

 

 

 

Hex

0x34

 

0x30

0x2D

0x0

 

 

 

 

 

 

 

 

 

 

 

0x35

 

D

 

 

 

 

 

 

 

Example3: Get Tint from TV-0007 and this command is valid.

 

 

 

 

The Tint value is 32.

 

 

 

 

 

 

 

 

 

Send (Hex Format)

 

 

 

 

 

 

 

 

 

 

 

Name

Lengt

 

ID

Command

Comman

Value

 

Value

Value

 

CR

 

 

h

 

 

Type

d

1

 

2

3

 

 

 

Hex

0x38

 

0x30

0x67

0X65

0x30

 

0x30

0x30

 

0x0

 

 

 

 

0x37

 

 

 

 

 

 

 

 

D

Reply (Hex Format)

 

 

 

 

 

 

 

 

 

 

 

Name

Lengt

 

ID

Command

Comman

Value

 

Value

Value

 

CR

 

 

h

 

 

Type

d

1

 

2

3

 

 

 

Hex

0x38

 

0x30

0x72

0x65

0x30

 

0x33

0x32

 

0x0

 

 

 

 

0x37

 

 

 

 

 

 

 

 

D

Example4: Get Tint from TV-07 , but the Brightness command ID is error and it is NOT in the

command table.

 

 

 

 

 

 

 

 

Send (Hex Format)

 

 

 

 

 

 

 

 

 

Name

Lengt

 

ID

Command

Comman

Value

Value

Value

CR

 

 

h

 

 

Type

d

1

2

3

 

 

Hex

0x38

 

0x30

0x67

0XD7

0x30

0x30

0x30

0x0

 

 

 

 

0x37

 

 

 

 

 

 

D

Reply (Hex Format)

 

 

 

 

 

 

 

 

 

Name

Lengt

 

ID

Command

CR

 

 

 

 

 

 

 

h

 

 

Type

 

 

 

 

 

 

 

Hex

0x34

 

0x30

0x2D

0x0

 

 

 

 

 

 

 

 

 

0x37

 

D

 

 

 

 

 

Example5 Get backlight sensor from TV-0007 and this command is valid. The lux value is 1786 (ASCII code).