First Alert CO400 Testing & Maintenance, What YOU Need to Know about CO, Weekly Testing

Page 4

TESTING & MAINTENANCE

WEEKLY TESTING

Test the CO Alarm once a week. If the CO Alarm ever fails to test correctly, have it replaced immediately! If the CO Alarm is not working properly, it cannot alert you to a problem.

DO NOT stand close to the Alarm when the horn is sounding. Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding.

Push and hold the Test/Silence button on the cover until the LED flashes. The alarm horn will sound 4 beeps, a pause, then 4 beeps. The ALARM (RED) light will flash.

The alarm sequence should last 5-6 seconds. If it does not alarm, make sure fresh batteries are correctly installed, and test it again. If the unit still does not alarm, replace it immediately.

If the alarm does not test properly:

1.Make sure that fresh batteries are installed correctly.

2.Be sure the Alarm is clean and dust-free.

3.Install fresh AA batteries* and test the Alarm again.

DO NOT try fixing the Alarm yourself – this will void your warranty! If the CO Alarm is still not operating properly, and it is still under warranty, please see "How to Obtain Warranty Service" in the Limited Warranty. Install a new CO Alarm immediately.

The Test/Silence button is the only proper way to test the CO Alarm. NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty.

*For a list of acceptable replacement batteries, see “Regular Maintenance.”

REGULAR MAINTENANCE

To keep the CO Alarm in good working order:

Test it every week using the Test/Silence button.

Vacuum the CO Alarm cover once a month, using the soft brush attach- ment. Never use water, cleaners, or solvents, since these may damage the unit. Test the CO Alarm again after vacuuming.

Replace the batteries when the CO Alarm “chirps” about every minute (the low battery warning).

The low battery warning should last for 30 days, but you should replace the battery immediately to continue your protection.

Choosing a replacement battery:

This CO Alarm requires two standard AA batteries. The following batteries are acceptable as replacements: Energizer E91. These replacement batteries are commonly available at local retail stores.

Use only the replacement batteries listed. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge.

DO NOT spray cleaning chemicals or insect sprays directly on or near the CO Alarm. DO NOT paint over the CO Alarm. Doing so may cause permanent damage.

Household cleaners, aerosol chemicals, and other contaminants can affect the sensor. When using any of these materials near the CO Alarm, make sure the room is well ventilated.

WHAT YOU NEED TO KNOW ABOUT CO

WHAT IS CO?

CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). Electrical appliances typically do not produce CO.

These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane.

Common appliances are often sources of CO. If they are not properly main- tained, are improperly ventilated, or malfunction, CO levels can rise quickly. CO is a real danger now that homes are more energy efficient. “Air-tight” homes with added insulation, sealed windows, and other weatherproofing can “trap” CO inside.

SYMPTOMS OF CO POISONING

These symptoms are related to CO POISONING and should be discussed with ALL household members.

Mild Exposure:

Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).

Medium Exposure:

Throbbing headache, drowsiness, confusion, fast heart rate.

Extreme Exposure:

Convulsions, unconsciousness, heart and lung failure. Exposure to carbon monoxide can cause brain damage, death.

Some individuals are more sensitive to CO than others, including people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. Members of sensitive populations should consult their doctors for advice on taking additional precautions.

FINDING THE SOURCE OF CO AFTER AN ALARM

Carbon monoxide is an odorless, invisible gas, which often makes it difficult to locate the source of CO after an alarm. These are a few of the factors that can make it difficult to locate sources of CO:

House well ventilated before the investigator arrives.

Problem caused by “backdrafting.”

Transient CO problem caused by special circumstances.

Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.

HOW CAN I PROTECT MY FAMILY?

A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average, healthy adults.

A CO Alarm is not a substitute for proper maintenance of home appliances.

To help prevent CO problems and reduce the risk of CO poisoning:

Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper air flow. Also, have a professional check for rust and corrosion, cracks, or separations. These conditions can prevent proper air movement and cause backdrafting. Never “cap” or cover a chimney in any way that would block air flow.

Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC companies offer appliance inspections for a nominal fee.

Make regular visual inspections of all fuel-burning appliances. Check appli- ances for excessive rust and scaling. Also check the flame on the burner and pilot lights. The flame should be blue. A yellow flame means fuel is not being burned completely and CO may be present. Keep the blower door on the furnace closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure appliances are vented to the outside. Do not grill or barbecue indoors, or in garages or on screen porches.

Check for exhaust backflow from CO sources. Check the draft hood on an operating furnace for a backdraft. Look for cracks on furnace heat exchangers.

Check the house or garage on the other side of shared wall.

Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a window or a door. Opening windows and doors can significantly decrease CO levels.

In addition, familiarize yourself with all enclosed materials. Read this manual in its entirety, and make sure you understand what to do if your CO Alarm sounds.

4

Image 4
Contents Table of Contents HOW Your CO Alarm WorksIntroduction USER’S ManualInstallation Understanding Your CO AlarmWhere CO Alarms should not be Installed Where to Install CO AlarmsHOW to Install Your CO Alarm If Your CO Alarm SoundsUsing the Silence Feature Testing & Maintenance Weekly TestingRegular Maintenance What YOU Need to Know about CORegulatory Information for CO Alarms General Limitations of CO AlarmsWhat Levels of CO Cause AN ALARM? Potential Sources of CO in the HomeLimited Warranty Troubleshooting GuideProblem This Means YOU should
Related manuals
Manual 6 pages 10.73 Kb

CO400 specifications

The First Alert CO400 is a highly reliable carbon monoxide detector designed to ensure the safety of your home and loved ones. Carbon monoxide (CO) is a colorless, odorless gas produced by burning fossil fuels, making it essential for every household to have an effective CO detector, and the CO400 stands out in this regard.

One of the primary features of the First Alert CO400 is its advanced electrochemical sensor technology. This technology provides accurate detection of carbon monoxide levels in the air, ensuring swift alerts that can save lives. With an audible alarm that reaches 85 decibels, users can be assured that they will be alerted in the event of dangerous CO concentrations.

Battery operation is another standout characteristic of the CO400. This detector runs on three AA batteries, which provide a reliable power source that ensures it remains functional even during power outages. The low battery indicator is a helpful feature, notifying users when it’s time to replace batteries, thus ensuring constant monitoring.

The CO400 is also designed with convenience in mind. Its compact and sleek design allows for easy installation in various locations around the home, including bedrooms, living rooms, and hallways. Installation is hassle-free, as it can be wall-mounted or simply placed on a shelf, making it versatile for different home layouts.

A notable technological aspect of the CO400 is its end-of-life signal, which alerts users when the unit has reached the end of its operational lifespan, usually around 5-7 years. This reminder feature is crucial, as it prompts users to replace their detector to maintain safety standards.

In terms of certifications, the First Alert CO400 meets stringent safety standards, assuring users of its reliability. It is UL listed, which signifies that it has passed rigorous safety testing.

Overall, the First Alert CO400 carbon monoxide detector combines cutting-edge technology with user-friendly features to provide a crucial layer of safety for homes. Its robust detection capabilities, easy installation, and reliable battery operation make it an essential device in the fight against the silent threat of carbon monoxide poisoning. Investing in this reliable detector is a proactive step towards ensuring the wellbeing of your family and creating a safer living environment.