First Alert CO615 user manual HOW Your Alarm Works, If Your CO Alarm Sounds

Page 3

HOW YOUR ALARM WORKS

THE COVER OF YOUR ALARM

47

12

3

5

6

1.Test/Silence Button: Press and hold to activate test, or to silence the alarm.

2.Display Button: Press to recall highest CO level recorded

3.POWER Light (GREEN)

4.Display

5.(Behind the Cover) Alarm Horn: 85 dB audible alarm for test, alarm, and unit malfunction warning.

6.Battery Compartment (Behind the Door)

7.Open door here

USING THE SILENCE FEATURE

NEVER disconnect the power to your Alarm to silence the horn—use the Silence Feature. Disconnecting the Alarm removes your protection!

The Silence Feature is intended to temporarily silence the horn while you identify and correct the problem.

To use the Silence Feature, press the Test/Silence button until the horn is silent.

If the Test/Silence button is pressed while the Alarm is in the silence mode, the alarm will start sounding again.

WHEN THE CO ALARM IS SILENCED...

The CO Alarm will remain silent for up to 4 minutes. While the Alarm is silenced, it will continue to monitor the air for CO. After 4 minutes, if CO levels remain potentially dangerous the horn will start sounding again.

The Silence Feature is intended to temporarily silence the Alarm horn. It will not correct a CO problem.

USING THE REMOTE CONTROL TEST/SILENCE FEATURE

Using the VOLUME or CHANNEL buttons on most remote controls, you can test or silence this CO Alarm from up to 12 feet (3.6 meters) away.

To Test or Silence the Alarm:

IF YOUR CO ALARM SOUNDS

WHAT TO DO IF CARBON MONOXIDE IS DETECTED

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In other words, when your CO Alarm sounds, you must not ignore it!

IF THE CO ALARM SOUNDS:

1.Operate the Test/Silence button.

2.Call your emergency services, fire department or 911. Write down the number of your local emergency service here:

_______________________________________________________________

3.Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re- enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.

4.After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identi- fied during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:

_______________________________________________________________

1. Make sure you have a clear path between you and the Alarm, free of any obstructions.

2. Point the remote at the front of the Alarm.

3. Press the VOLUME or CHANNEL button for at least 5 seconds.

If the Alarm does not respond to your remote control:

• You may be standing too far away.

• Your remote may not be compatible.

• You did not hold the button on your remote for at least 5 seconds.

AC power must be present to Silence the low battery chirp.

SILENCING THE LOW BATTERY WARNING

This Silence Feature can temporarily quiet the low battery warning “chirp” for up to 8 hours if AC power is present. You can silence the low battery warning “chirp” two ways:

1.Manually: Press the Test/Silence button on the Alarm cover until you see the Green LED flicker, acknowledging the button-press.

2.Using Your Remote Control: Standing no further than 12 feet (3.6 meters) away from the Alarm, aim your IR remote at the Alarm and press the CHANNEL or VOLUME button for at least 3-5 seconds.

The display will flash “SILENCE” for 8 hours while the low battery warning “chirp” silence feature is activated. After 8 hours, the low battery “chirp” will resume. The Alarm will continue to operate as long as AC power is supplied. However, replace the battery as soon as possible, to maintain protection in event of a power outage.

USING THE PEAK CO MEMORY

The CO Memory Feature lets you check the highest level of CO recorded.

To check CO Memory:

1. Press the Display button until the peak CO level is displayed.

To clear CO Memory:

1. While checking CO memory, press or hold the Display button until “CLEAR” is displayed.

2. Press or hold the Display button until the CO Memory is cleared.

NOTE: The highest CO level will be saved, even after an AC power interruption, until you clear it. DO NOT clear the CO Memory reading if you plan to call someone to investigate a CO problem! Clear the CO Memory reading only after the investigator has checked your home.

3

Image 3
Contents USER’S Manual Table of ContentsBasic Safety Information InstallationActivating the Battery BACK-UP Where this Alarm should not be InstalledBefore YOU Begin Installation HOW to Install this CO AlarmIf Your CO Alarm Sounds HOW Your Alarm WorksHorn Display Understanding the LIGHT, HORN, and Display PatternsCondition LEDWeekly Testing Regular MaintenanceWhat YOU Need to Know about CO What Levels of CO Cause AN ALARM? Regulatory Information for CO AlarmsGeneral Limitations of CO Alarms Regulatory Information for CO AlarmsHow to Obtain Warranty Service Troubleshooting GuideLimited Warranty If your Alarm does this It means You should

CO615 specifications

The First Alert CO615 is a highly reliable carbon monoxide detector that combines advanced technology and essential features to ensure the safety of your home and loved ones. As an essential tool for detecting the presence of carbon monoxide, a colorless and odorless gas that can be fatal, the CO615 offers peace of mind through its efficient functionality.

One of the standout features of the CO615 is its electrochemical sensor, which is highly sensitive to low levels of carbon monoxide. This technology ensures that the detector can respond quickly to the presence of this dangerous gas, providing timely alerts and allowing for prompt action. The detector has a clear and loud alarm, which emits a powerful sound to alert residents of any potential danger.

The CO615 also includes a convenient digital display that shows the current level of carbon monoxide in the environment. This feature not only allows users to monitor the air quality continuously but also helps them understand if the levels are creeping up or are within a safe range. The display also features a battery status indicator, so users can easily check if the device is functioning properly.

In terms of power, the CO615 operates on three AA batteries, which provides a reliable source of energy. Additionally, this model is designed with a long battery life, ensuring that the unit performs effectively over time without the need for frequent replacements. The low battery chirp signal acts as a timely reminder when it's time to change the batteries, preventing the risk of the unit becoming inactive.

Installation is straightforward, as the CO615 can be mounted on walls or placed on flat surfaces. Its compact design allows it to blend seamlessly into any home environment. The unit is also backed by a comprehensive warranty, giving buyers confidence in their investment.

Overall, the First Alert CO615 is a top choice for those seeking a dependable carbon monoxide detector. Its advanced electrochemical sensor, clear digital display, and user-friendly design make it a practical solution for maintaining a safe living space. With its emphasis on efficiency and reliability, the CO615 serves as a crucial safeguard against the dangers of carbon monoxide exposure.