For the product, its color and style, please refer to the actual product as standard.
Please keep this manual in a safe place for future reference. If you should have any doubt or dissatisfaction with our product or service, including product technology, quality, installation and maintenance, please contact us immediately so that we can deal with your suggestions in a proper way.
• Product profile
As the gas detection expert, Honeywell Analytics brings together nearly
200 collective years of expertise in design, manufacture and technology. As the leader in gas detection and alarm equipment industry in the world, we apply high-precision detection standards to domestic gas leakage alarm systems. By integration of powerful catalytic flammable sensing technology and advanced electronic technology, Honeywell is dedicated to providing multiple protections for both our customers and their properties.
• Function and indication chart
| Operation | | LED | Relay | | B | | | |
| Description | | u | Timing/Interval | |
| | | | | | | |
| | | G | R | Y | Al | Ft | | z | | | |
| | | | z | | | |
| | | | | | | | | | | |
| Normal | When no gas is present, the green | Y | N | N | De | En | | N | Always G LED on if | |
| Operation | LED | | power is normal | |
| | | | | | | | | | | |
| Successful | On demand test result by press the | | | | | | | | 8 times beep with red | |
| button. Red LED and Yellow LED will | Y | Y | Y | En | En | | Y | LED flash 4 times and | |
| Test* | be blink in order. After then return to | | | | | | | | then yellow LED flash | |
| | normal mode | | | | | | | | 4 times | |
| Unsuc- | On demand test result by press the | Y | N | Y | De | De | | N | Same as default condition | |
cessful Test | button. After then return to normal | | |
| | | | | | | | | |
| | mode | | | | | | | | | | |
| | When detects gas, it will give the | | | | | | | | | | |
| Alarm | alarm signal continuously. The red | Y | Y | N | En | En | | Y | 8 times beep with red | |
| LED and sounder will annunciate | | |
| | | LED flash 8 times | |
| | When gas level is less then alarm | | | | | | | | | | |
| | point, return to normal operation. | | | | | | | | | | |
| | | | | | | | | | | | |
| Hush | If required, the audible alarm can be | | | | | | | | | | |
| silenced for 5 minutes by pushing | Y | Y | N | En | En | | N | Red LED flash 4 times | |
Function | the button marked “Test”. The red | | each time | |
| | alarm will continue to flash for 5 | | | | | | | | | | |
| | minutes | | | | | | | | | | |
| | If gas is still present after 5 minutes | | | | | | | | | | |
| | hush period, the audible alarm will | Y | Y | N | En | En | | Y | Same as alarm condition | |
| | sound | | |
| | | | | | | | | | | |
| | | | | | | | | | | |
| | End of life time(5 years) | Y | N | Y | De | De | | Y | 3 long chirps/min | |
| | | | | | | | | | | | |
| Trouble | Cell health trouble/No cell | Y | N | Y | De | De | | Y | 1 long chirps/min | |
Condition | | |
| | | | | | | | | | | | |
| | Power trouble | N | N | Y | De | De | | Y | 2 long chirps/min | |
| | | | | | | | | | | | |
| | EEPROM CRC fail/ Program | N | N | Y | De | De | | Y | Continues beep | |
| | code fail | | |
| | | | | | | | | | | |
| | | | | | | | | | | | |
* Alarm relay shall be teseted often 5 seconds of button when normal conduction.
Power LED (green)
Alarm LES (red)
Fault (yellow)
1.Power LED (green): indicates the power system is in normal operation
2.Alarm LED (red): indicates the concentration of combustible gas leakage reaches the set value
3.Fault LED (yellow): indicates the alarm is in fault condition
Flush mounting — in case flush mounting is selected, the adapter for mounting is not necessarily used. You need to dis-connect the AC power wire and remote sensor wire from main Assy and take off the adapter first.
Remote sensor connector
Remote sensor cable
Cut off the strip on the left edge of the host with a knife, and fixed the machine body into the groove previously excavated on the wall with screws (detailed dimensions of the groove: width 134mm~136mm, height 92mm~ 93mm).
Cut off
If relay is used for signal output, then remove the wire trunking and fix it with screws again after connecting the signal line to the corresponding connecting terminal.
| Fault | NC | NC:Normal close |
| COM | COM Alarm |
| |
| | | NO:Normal open |
Press down the panel onto the host to complete the installation.
• Procedures for remote sensor installation
Fix the sensor onto the ceiling with screws.
•Incorrect mounting position
1.Places where exhaust, steam and oil smoke from gas appliances may directly influence
2.Places near to the air inlet, exhaust fan, door and window where favorable ventilation is ensured
3.Places which are fenced off by the window curtain, vertical curtain, cabinet door, ceiling and cross beam, etc.
4.Places with high temperature and moisture like cooking room and boiler room, etc.
5.Places where power supply of the alarm may possibly be switched off
6.Places outdoor or where the temperature is lower than -10 °C or higher than +55 °C
•Precautions on using
1.Do not switch off the power supply of the alarm, otherwise the alarm may not work when gas leakage occurs.
2.Do not touch any part of the power supply with wet hand(s) as this could cause risk of electric shock.
3.Do not remove or retrofit the alarm.
4.Do not use volatile matters in the vicinity of the alarm, like hair spray, pesticide, paint, adhesive agent and alcohol, so as to avoid false alarm an eliminate any influence on the service life of the sensitive elements.
5.Do not eject high-concentration gas into the access opening to avoid performance of the sensor.
6.Frequently check the power LED (green) is always on.
7.Press down the self-test button of the detector once every 6 months to check it is in normal standby state.
8.In case a fault happens in the alarm, please contact our company or the local representative office immediately.
9Never connect the power supply to any signal output terminal.
10.Prevent the product from falling down from a high level during installation and operation, otherwise the performance of the product may be impaired.
11.Never attempt to replace the remote probe or change the length of its wire by any unauthorized person.
12.Never clean the alarm with a cleaning agent.
13.Please keep the alarm away from silicon-contained material.
•Our company will not assume any responsibility for product damage or loss of function caused by the following reasons:
1.Consumer’s disassembly or intentional damage
2.Force majored like fire, earthquake, lightening, abnormal voltage, etc.
3.Wrong installation position or failure to switch on power supply of the detector
4.Expiration of the lifetime
5.Falling down, impact and other faults and damages incurred by the consumer
6.Other contamination, damages, faults or damages not caused by the manufacturer
Honeywell Trading (Shanghai) Ltd | |
430 Li Bing Road | |
Zhangjiang Hi-Tech Park | |
Shanghai, China | H_RFI Manual_09_V1_AP |
|