Macurco CM-S1 specifications General Information, Location, Specifications, Installation

Page 1

MACURCO GAS DETECTORS

CM-S1 INSTALLATION AND

 

OPERATION INSTRUCTIONS

GENERAL INFORMATION

The CM-S1 is a low voltage (12-24 VDC) all electronic detector of Carbon Monoxide (CO). The CM–S1 is designed for connection to UL Listed alarm control panels (Fire or Fire/Burglar or Critical Process Management Equipment). NOTE: Any time the words “Control Panel” or “Alarm Panel” or “Alarm Control Panel” are used in these instructions, what is meant is a UL Listed Fire or Fire/Burglar or Critical Process Management Equipment. Alarm control panels that work on 12 or 24 VDC can provide battery backup to the CM-S1 detectors. This carbon monoxide detector is designed to detect CO gas from ANY source of combustion. It is NOT designed to detect smoke, fire or any other gas.

LOCATION

There are two usual sources of CO in homes -- defective heat sources (furnaces or wood burning stoves) and automobiles running in adjoining garages. The CM-S1 can provide protection from these sources, as well as any other sources of CO.

For best protection, mount a CM-S1 in the hallway near each bedroom area. In addition, another CM-S1 may be mounted just inside the door from the adjoining garage. Consider placing another detector in a bedroom that is adjacent to a furnace room.

Do NOT mount the unit in the garage. Do NOT mount the CM-S1 where the normal ambient temperature is below 40° F (4.4° C) or exceeds 100° F (37.8° C), or within 5 feet (1.5 meters) of a cooking appliance.

SPECIFICATIONS

 

Voltage: 12-24 VDC

Current (standby/alarm @ 12-24V): 20mA/40mA (250 mA peak for 14ms/sec)

Size: 3 1/8” x 5 1/8” x 1 ½”

Power (standby/alarm @ 12V): ¼ Watt / ½ Watt

Shipping Weight (each): One pound

Power (standby/alarm @ 24V): ½ Watt / 1 Watt

Alarm Relay: SPDT, 1 Amp, 60 VDC, 60 VA

Operating Temperature Range: 32° to 120° F

Alarm Setting: Per UL 2034

Buzzer Rating: 85 dBA at 10 Feet

Color: White

 

INSTALLATION

See wiring diagram on page 4 for information on connections of the CM-S1. Macurco recommends a minimum of 22 AWG wire for runs up to 200 ft., and 18 AWG wire for longer runs.

Mount the CM-S1 at the height that people breath: 4 to 5 feet (1.2 to 1.5 meters) above the floor. The unit can be placed vertically or horizontally on a wall, so the information on the front of the CM-S1 can be read in a normal manner. The word UP and a directional arrow on the internal cover indicate the correct mounting orientation of the detector.

A rear housing enclosure is included with the CM-S1 faceplate. This enclosure configuration allows the unit to mount-flush on a wall. Wiring is routed through an access area on the base of the rear housing. A thin mid-plate enclosure component is also supplied with the CM-S1. This mid- plate component is used to mount the CM-S1 on a 2 x 4 single-gang, or “handy” electrical box, provided by the installer. The CM-S1’s faceplate component (with the detector attached) is then mounted on the mid-plate component. Electrical connections to the CM-S1 are made via the supplied five-conductor pigtail cable. The pigtail cable is first connected to the control panel wiring by means of wire nuts (refer to wiring diagram on page 4 for proper pigtail wiring). The pigtail cable’s connector then snaps into the mating connector on the back of the CM-S1 PCA, allowing easy installation and replacement of it. For proper detector operation, ensure that the CM-S1 is connected to a continuous source of power (not controlled by a wall switch). The CM-S1 power consumption figures represent worst-case conditions and will vary as the applied DC voltage varies.

The alarm relay of the CM-S1 is a dry contact and rated at 1 Amp, 60 VDC, 60 VA. It is not suitable for fan control use. When connecting the units to remote buzzers or other devices (all buzzers or "other devices" must be UL approved), make sure that the load does not exceed the relay’s rating. External buzzers must be capable of generating a sound output greater than 85 dBA at 10 ft.

Document #679-800-001

Page 1 of 4

Rev. 1.1, Jan 9, 2006

Image 1
Contents Installation SpecificationsGeneral Information LocationOperating Instructions Trouble Indicator RESET/SILENCE SwitchErrors MaintenanceWiring Diagrams Typical Connection of TWO CM-S1s to AN Alarm Control Panel

CM-S1 specifications

The Macurco CM-S1 is a sophisticated gas detection device designed to monitor and detect hazardous gases within various environments. Its primary focus is on safety, ensuring that users are alerted to potential dangers before they escalate into critical situations. The CM-S1 is widely used in commercial kitchens, laboratories, industrial settings, and other places where gas leaks may occur.

One of the standout features of the Macurco CM-S1 is its dual detection capability, allowing it to identify both carbon monoxide (CO) and natural gas (methane). This versatility makes it an invaluable tool for enhancing safety in various applications. The device employs advanced semiconductor technology for gas detection, which provides reliable and accurate readings, even in challenging conditions. The sensors are designed to deliver rapid response times, ensuring that any potentially harmful gas concentrations are detected almost immediately.

Another significant characteristic of the CM-S1 is its comprehensive digital display, which provides real-time data regarding gas levels and operational status. Users can see clear indicators of current gas concentrations, along with status updates that ensure optimal functioning. The device also features multiple alarm indicators, including audible, visual, and vibration alerts, ensuring that personnel are quickly made aware of any dangerous situations.

The Macurco CM-S1 is designed for easy installation and setup. It can be mounted on a wall or ceiling, providing flexibility depending on the specific environment. Additionally, the unit's compact design allows it to fit comfortably in various spaces without becoming obtrusive. The device is powered by a standard AC power supply, with a battery backup feature to ensure constant operation even during power outages.

For added convenience, the CM-S1 is equipped with user-friendly calibration and testing modes. This feature allows facility managers and safety personnel to conduct regular maintenance checks and adjustments, ensuring that the device remains fully functional.

In summary, the Macurco CM-S1 is an advanced gas detection solution that combines reliable performance with user comfort. Its cutting-edge technology, dual detection capability, and user-centric design make it an essential tool for safeguarding environments against potentially lethal gas leaks. Investing in the CM-S1 not only enhances safety but also promotes a proactive approach to hazard management in various settings.