Friedrich D50C, D65C, D30C, D40C OperatingInstructions, Water bucket must be properly installed

Page 11

OperatingInstructions

7 6

5 4 3

CONTROL PANEL

1.POWER key --- Pressing this key once turns the dehumidifier "ON" and pressing again turns the dehumidifier "OFF".

2.HUMIDITY CONTROL keys --- Are used to select the desired humidity setting.

A : Used to raise the desired humidity setting.

_ : Used to lower the desired humidity setting.

The desired humidity can be selected within a range of 35% to 70% RH in increments of 5%.

If you press the _ key once again at 35%RH, "On" mode is selected. In "On" mode the unit operates continuously, regardless of humidity conditions.

3.HUMIDITY SETTING display --- The desired humidity selected is displayed here.

4.FAN SPEED key --- Is used to set the fan speed as "High" or "Low".

Pressing this key changes the fan speed from High -_ Low -, High.

The selected fan speed is indicated by indicator lights marked "High" and "Low".

5.TIMER key --- It is used to select the type of operation.

Select either 2 or 4 hr. On/Off for cycled operation.

in this case the unit will run for 2 or 4 hours, and then shut off completely for 2 or 4 hours. The cycle will repeat until you change the setting.

When TIMER key is pressed, the TIMER indicator lights shift as 2hr.On/Off -, 4hr.On/Off -_Off.

6.BUCKET FULL Indicator --- This light glows when the bucket is full and needs to be emptied. It also

glows, when the bucket is not properly positioned. When bucket ful! indicator light glows, the compressor and fan wi!l turn "OFF".

7.AUTO RESTART --- Once the power is restored after a power outage, the unit begins to operate at its previous operation setting. The fan will run by default for 2 minutes. After 2 minutes both fan and compressor will be ON or OFF depending on the humidity conditions.

TO OPERATE THE DEHUMIDIFIER:

1.Plug the power cord into the electrical outlet. Press the POWER key.

2.Set the Humidity control between 35% to 70% for normal operation.

For less humidity, press the _ HUMIDITY CONTROL key.

For higher humidity, press the A HUMIDITY CONTROL key.

3.Press the TIMER key, to set the amount of time for which you want the unit to cycle On and Off. The time can be set for 2 hours or 4 hours.

4.If you want to change the fan speed, press the FAN SPEED key. Each time the FAN SPEED key is pressed the fan speed changes as High -, Low -, High.

5.Press the POWER key to stop the unit manually.

Water bucket must be properly installed.

The dehumidifier will not run if the bucket is not properly installed,

The dehumidifier shuts off when the desired humidity setting is reached.

Owner's Manual 11

Image 11
Contents Friedrich Dealers Name Date Purchased Model # Serial #Read ALL Instructions Prior to USE SafetyPrecautionsIt may cause electric shock Installation Safety Precautions Preparing for Operation PriortoOperationParts Symbols Used in this ManualThis symbol alerts you to hazards that could cause harm to Preferred method ElectricalSafetyTemporary USE of AN Extension Cord Temporary USE of AN AdapterOperatingInstructions Water bucket must be properly installedHose attachment wilt Automatic Shut OFFChoosing the Proper Location for Your Dehumidifier InstallationInstalling the Dehumidifier Properly Cleaning the BucketBe careful! Coils have sharp edges Electrical Shock HazardDehumidifier may be operating abnormally when TroubleshootingFriedrich

D40C, D65C, D30C, D50C specifications

Friedrich, a name synonymous with quality in the air conditioning industry, has designed a line of commercial cooling units that include models D30C, D40C, D50C, and D65C. Each of these models has been meticulously engineered to meet the diverse needs of businesses looking to maintain a comfortable environment while ensuring energy efficiency and reliability.

The Friedrich D30C, D40C, D50C, and D65C units are known for their robust construction and cutting-edge technology. One of the standout features across this line is the use of advanced inverter compressor technology, which significantly enhances energy efficiency by adjusting the compressor speed based on the cooling demand. This not only reduces energy consumption but also minimizes wear and tear on the unit, leading to a longer lifespan and reduced maintenance costs.

A key characteristic of these models is their superior airflow management. The units come equipped with multiple fan speeds and a variety of airflow modes, including quiet mode for minimal noise disruption and turbo mode for rapid cooling. This flexibility allows businesses to tailor their cooling needs according to the specific requirements of the space they are serving.

Another innovative aspect of the Friedrich D series is the integration of smart technology. Many models feature Wi-Fi connectivity that enables remote operation via a mobile app. This allows users to adjust settings, set schedules, and monitor energy usage from anywhere, providing convenience and control that is particularly beneficial for large commercial spaces.

In terms of design, the D30C, D40C, D50C, and D65C boast a sleek exterior that fits seamlessly into any commercial environment. Additionally, these units are designed with a focus on user-friendly controls. The intuitive interface simplifies operation, making it easy for staff to adjust settings as needed.

Additionally, the D series includes an array of filtration systems that help improve indoor air quality. These filters capture dust, allergens, and other particulates, ensuring that the air circulated within a commercial space is clean and healthy.

Overall, the Friedrich D30C, D40C, D50C, and D65C models exemplify a blend of efficiency, innovative technology, and user-friendly design, making them ideal solutions for businesses seeking high-performance air conditioning systems. Whether for retail locations, offices, or larger commercial establishments, these units promise to deliver reliable cooling, exceptional control, and comfort for all users.