Dri-Eaz 2000 LG, 1200, 80, 2400 LG owner manual Warranty, Periodic Maintenance as needed

Page 3

PUMP TUBE: Make sure the pump tube is completely un- wrapped and not kinked. Failure to do so can cause water to back up in the pump and leak out. The control panel may signal this problem by displaying “ER9.”

KEEP OUT DUST. Keep dust from drywall, demolition, and other sources out of the coils. Failure to do so can cause the unit to overheat, leading to compressor failure or other problems. Do not run the unit during sanding, painting or other operations pro- ducing airborne particulate. When dust is present, use the op- tional pleated paper filter to keep more dust out of the unit; also, inspect and clean the coils as required.

USE A CLEAN FILTER. Keep a clean filter in the unit at all times to keep out dust. When using a foam filter, clean with a vacuum, or wash with water and mild detergent and allow it to dry. When using paper filters, discard the filter when visibly dirty and insert a clean one.

SHINE EXTERIOR: Use a sponge and mild detergent for regu- lar cleaning. Do not pour or run water onto the unit or allow wa- ter to soak the touchpad control. Bring back the original shine with a vinyl cleaner-polish.

Periodic Maintenance (as needed)

Make sure unit is unplugged. Remove housing as needed to permit access to interior parts.

KEEP COILS CLEAN. Dirty coils do not remove water efficiently. Inspect them regularly, especially if operating in dusty environ- ments. Clean if they are visibly dirty.

First make sure coils are dry, then blow them clean with direct compressed air from both sides of the coil. Do NOT hold too close to the coils, as high-pressure air may fold the fins.

If sticky or oily residue remain, do a wet cleaning. Use a squirt bottle to flush the coil with water and a little detergent. Do NOT run a hose or pressure washer on the coils, or permit water to enter the electrical compartment.

Remove dirt buildup with an aluminum evaporator coil cleaner available from a refrigeration supply outlet. Follow product direc- tions carefully.

When cleaning coils, also make sure that the drain tray, drain hose, and filter cover are free of dirt.

PUMP SYSTEM: Inspect and clean the pump system regularly to maintain effective operation. Remove the four screws holding down the pump cover. Clean the catch basin. Make sure the float shaft operates smoothly and does not stick in the OFF position. Use a pipe cleaner to clean the gravity drain hose.

WARRANTY

FILL OUT WARRANTY CARD: Please stop before proceeding and fill out the warranty card.

INSPECT ON ARRIVAL: When your Dri-Eaz product arrives, check immediately for signs of shipping damage. If you notice damage, save the shipping carton for claim purposes, and im- mediately report the problem to your supplier and the shipping company. Also, save the carton for shipping in case your product ever needs repair at a remote location.

Dri-Eaz promises, to the original purchaser, to perform the following as needed to correct defects in materials and workmanship:

7 Years on Housing: Repair or replace the housing of a Dri-Eaz Airmover or Dehumidifier, for seven years from date of purchase. (United States and Canada only.)

4 Years on Compressor, Coils and Rotor: Repair or replace the compressor and/or coil of a DrizAir Dehumidifier, or the desic- cant rotor of a DriTec Dehumidifier, for four years from the date of purchase. (United States and Canada only.)

1 Year on Parts and Labor: Cover parts and labor costs for the repair of a Dri-Eaz Airmover, Dehumidifier, Instrument, Acces- sory, and other product except Marketing Products, for a period of one year from the date of purchase.

90 Days on Shipping: Cover shipping costs for the repair of a Dri-Eaz Airmover, Dehumidifier, Instrument, Accessory, or other product except Marketing Products, both to and from the Service Center, for a period of 90 days from the date of purchase.

LIMITATIONS: This warranty shall not extend to any products showing effects of misuse, accident damage, disassembly, al- teration, lack of proper maintenance, corrosive chemicals, im- proper voltage, unauthorized repairs, use of other than genuine parts and materials, fire, flood, normal wear and tear, or any other causes beyond Dri-Eaz Products' control. The warranty obligation extends only to the repairs or replacement of parts found, upon Dri-Eaz Products' examination, to be defective. The foregoing constitutes the entire warranty and no other warranty, liability, contingency or responsibility, direct, indirect, conse- quential or in any way connected with the sale or operation of products is expressed or implied.

TO RECEIVE WARRANTY SERVICE: You must write or call for a Return Authorization. You must have the serial number avail- able. The Dri-Eaz Service Department must authorize all costs, including shipping, for any Service Centers worldwide. Please direct questions to an authorized distributor, or to Dri-Eaz at (360) 757-7776, extension 238.

Copyright 2000, 2002 Dri-Eaz Products, Inc.

3

Image 3
Contents HOW to USE Dehumidifiers Operating InstructionsPositioning Dehumidifiers Electrical Connections MaintenancePeriodic Maintenance as needed WarrantySpecifications

2000 LG, 2400 LG, 1200, 80 specifications

The Dri-Eaz 2400 LG is a powerful solution designed for effective water damage restoration and air movement applications. Known for its efficiency, the 2400 LG can significantly enhance drying times for various environments, from commercial properties to residential homes. One of its standout features is the high-velocity airflow, which is crucial for removing moisture effectively from floors, walls, and other surfaces.

Equipped with advanced technology, the Dri-Eaz 2400 LG utilizes an innovative design that maximizes performance while minimizing energy consumption. This makes it not only an efficient choice but also an environmentally friendly option for restoration professionals. The unit incorporates an adjustable airflow system, allowing users to customize air movement based on the specific needs of the job. This flexibility ensures optimal drying conditions and promotes a faster recovery process.

The structure of the Dri-Eaz 2400 LG is built to last, featuring durable materials that can withstand the rigors of daily use in demanding environments. Its compact form allows for easy transportation and setup, which is essential for professionals who are constantly on the move. Additionally, it includes integrated stacking capabilities, making it easy to store multiple units when not in operation.

Another noteworthy characteristic of the Dri-Eaz 2400 LG is its low operational noise level. This feature is especially beneficial in residential areas or sensitive environments where excessive noise could be disruptive. Users can operate the unit without disturbing occupants, making it a preferred choice for restoration tasks within homes and businesses.

The Dri-Eaz 2400 LG is also designed with user-friendly controls, allowing operators to quickly adjust settings and monitor performance. Advanced safety features ensure that the unit operates within designated parameters, reducing the risk of damage or failure during use.

In summary, the Dri-Eaz 2400 LG is an exceptional choice for anyone involved in water damage restoration or air movement tasks. With its powerful airflow, energy efficiency, durable construction, low noise output, and user-friendly design, it delivers the performance and reliability that modern restoration projects demand. This makes it a valuable addition to any restoration professional’s toolkit.