Aprilaire 600A, 700M, 500M, 600M, 400A, 500A, 700A owner manual Model

Page 9

& 360

REQUIRED MAINTENANCE INSTRUCTIONS

(APRILAIRE HUMIDIFIER MODELS 350 & 360)

WARNING

120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing.

REQUIRED MAINTENANCE INSTRUCTIONS

(APRILAIRE HUMIDIFIER MODEL 400A)

CAUTION

Sudden operation may cause personal injury or property damage. Turn Humidifier Control to “OFF” or lowest setting before servicing.

400A

MODELS 350

4

2

5

3

8

9

1.

Inlet Grille

2.

Distribution Tray

3.

Scale Control Insert

4.

Distribution Tray Cover

5. Water Panel Evaporator

1.Front Cover

2.Feed Tube

3.Integral Bypass Damper

4. Water Panel Evaporative

1

Assembly

 

5.Distribution Tray

6.“V” Notches

7.Water Panel Evaporator

8.Scale Control Insert/Float Chamber

9.Overflow Drain Line

10.Float Cover

11.Float

12.Water Level Sensor Assembly

6

5

4

8

7

 

3

11

2

10

12

9

90-1077

MODEL

6

7

1

6. Drain Spud

7. Power Cord

8. Metal Housing

9. Water Panel

Evaporative Assembly

1.

Note Humidifier Control setting and turn dial to the “OFF” position.

2.

Turn off water supply. Turn the integral bypass damper (3) to the “SUMMER” position.

3.

Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off base

 

with both hands.

4.

Carefully pull the plastic feed tube (2) out of the distribution tray (5) at the top of the Water

 

Panel evaporative assembly (4). Tip the Water Panel evaporative assembly forward and lift it

1.Note Manual Humidifier Control setting and turn dial to the “OFF” position.

2.Disconnect electrical power and turn off water supply.

3.Remove inlet grille screws (1). Remove grille from metal housing (8).

4.Lift the Water Panel evaporative assembly (9) out of the humidifier housing (8).

5.To remove the distribution tray (2) from Water Panel evaporative assembly (9), push down on tray and pull out scale control insert (3). To clean the “V” openings of the tray, gently pry the distribution tray cover (4) from the tray. Lightly scrape out or brush off any mineral deposits, being careful not to stretch or loosen the synthetic fabric liner. Soaking the tray in vinegar or a lime-removing agent is helpful when trying to remove stubborn mineral deposits.

6.Slide the Water Panel evaporator (5) out from the scale control insert (3) and dispose of the Water Panel. Clean the scale control insert of mineral deposits. Replace the Water Panel evaporator (Stock No. 35) with a Genuine Aprilaire Water Panel. Slide the Water Panel back into the scale control insert (3) and snap the distribution tray cover (4) into the distribution tray (2). Then snap the distribution tray back into the scale control insert.

7.Inspect the plastic feed tube by gently flexing it and looking for cracks or signs of wear. Replace tube if it is cracked, brittle or has been damaged.

8.Remove the drain line from the bottom of the humidifier and flex it to loosen any mineral deposits or blockage. Then flush it with water under pressure. If it does not properly clear, replace it. Slip the drain line back onto the drain fitting (6). Make sure the drain line has a constant downward slope and is not flattened or blocked.

9.Reinstall Water Panel evaporative assembly (9) and intake grille (1).

10.Reconnect electrical power (7) and turn on water supply.

11.Turn up Manual Humidifier Control and check system operation.

12.Set Manual Humidifier Control to its original position.

 

out of the humidifier. Do not tip the Water Panel evaporative assembly more than needed to

 

clear the housing to avoid over-bending the water level sensor assembly (12).

5.

Unsnap the distribution tray (5) from the scale control insert (8). Lightly scrape out or brush

 

off any mineral deposits, being careful not to stretch or loosen the synthetic fabric liner.

 

Soaking the tray in vinegar or a lime-removing agent is helpful when trying to remove

 

stubborn mineral deposits.

6.

Slide the used Water Panel evaporator (7) out of the scale control insert/float chamber and

 

dispose of the Water Panel.

7.

Remove the float cover (10) and inspect the floats (11) and float chamber for mineral build-up.

 

Remove deposits as needed from floats, float chamber and scale control insert. Wash the

 

parts with a disinfecting cleaner. Reassemble the floats and float cover. Make sure stems of

 

both floats extend through openings in float cover and that floats move freely up and down.

8.

Inspect the plastic feed tube (2) by gently flexing it and looking for cracks or signs of wear.

 

Replace tube if it is cracked, brittle, or has been damaged.

9.

Slide a new Aprilaire No. 45 Water Panel evaporator (7) into the scale control insert/float

 

chamber (8). Snap the distribution tray (5) back on the scale control insert (8).

10.

Reinstall the Water Panel evaporative assembly (4) into the humidifier. Take care not to over-

 

bend the water level sensor assembly. Push the top of the Water Panel evaporative assembly

 

firmly back until it snaps into place.

11.

Push the end of the feed tube back firmly into the distribution tray. Replace the front cover.

12.

Under normal operation the overflow drain line (9) will never have water in it. However,

 

inspect it for mineral deposits and replace if necessary. Make sure the drain line has a

 

constant downward slope and is not flattened or blocked.

13.

Turn on the water supply. Return integral bypass damper to appropriate position.

14.

Check system operation:

 

Automatic Digital Humidifier Control: (Automatic or Manual mode) Check system operation

 

and reset Change Water Panel indicator by setting the knob to “Test/Reset”. With HVAC

 

blower operating and HVAC calling for heat, humidifier will operate for one minute. DO NOT

 

LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE.

15.

Set Humidifier Control to its original position.

- 14 -

- 15 -

Image 9
Contents Humidifiers Introduction Table of ContentsPrinciple of Operation Automatic Mode Automatic Digital Humidifier Control Indicator LightsWater Panel Change Indicator Manual ModeTEST/RESET Additional InformationCheck the Humidifier Operation Operating InstructionsAutomatic Digital Humidifier Control Not Operate Manual Humidifier ControlAnnual Maintenance Effect of Water CharacteristicsControl in Test Mode or Humidifier will not Operate Additional Information for ALL ModelsPeriodic Preventative Maintenance Water Line Inspection and Service InstructionsAnnual Summer Shutdown Model 600A & 600M Warranty Registration Limited Warranty
Related manuals
Manual 11 pages 28.78 Kb Manual 11 pages 16.26 Kb Manual 11 pages 23.7 Kb Manual 2 pages 53.65 Kb Manual 2 pages 60.13 Kb Manual 2 pages 42.33 Kb

700A, 500A, 600A, 500M, 700M specifications

Aprilaire is a leading brand in the field of indoor air quality, and its series of humidifiers like the 600A, 700M, 400A, 500A, and 600M have been designed for optimal performance and user convenience. These humidifiers are engineered to maintain ideal moisture levels in your home, which is especially important during dry winter months.

The Aprilaire 600A is an advanced model equipped with automatic humidity control. This feature enables the humidifier to adjust moisture levels based on the outdoor temperature, ensuring a comfortable indoor environment throughout the changing seasons. The 600A is also easy to install and integrates seamlessly with your home’s HVAC system, supplying humidity throughout the entire house.

In contrast, the 700M is a manual humidifier option that offers flexibility in controlling humidity levels. This model is particularly suitable for homeowners who prefer a hands-on approach. The 700M can deliver up to 0.75 gallons of moisture per hour, making it effective for larger homes or spaces where humidity needs to be closely monitored.

The Aprilaire 400A and 500A models are geared towards versatility and space efficiency. The 400A, designed for homes with lower humidity requirements, operates quietly and offers a less invasive installation. It is suitable for areas up to 4,000 square feet, making it ideal for many average-sized homes. The 500A, on the other hand, is particularly designed for homes with a higher demand for moisture, providing consistent humidity control for larger spaces.

The Aprilaire 600M is another manual option that combines a straightforward user interface with robust performance. Similar to the 700M, it allows users to manually adjust humidity levels but features a slightly superior output rate.

One of the standout characteristics shared among these models is their ability to minimize the effects of dry air. By maintaining the right humidity levels, these humidifiers help reduce the likelihood of respiratory issues, dry skin, and static electricity, along with protecting wooden furniture and flooring from damage.

Overall, the selection of Aprilaire humidifiers offers something for every homeowner, from automated models that take the guesswork out of humidity control to manual options that provide a personal touch. Each model boasts its unique features while ensuring a healthier and more comfortable living environment year-round.