2.4C Ducting for Fresh Air
Fresh air can be brought into the structure continuously by connecting a duct from outside to the
1.Outside air is filtered before entering the building.
2.Outside air will be dehumidified before entering if the
3.Drawing air from outside and blowing inside aids in pressurizing the structure. This helps prevent unfil- tered and humid air from entering elsewhere. It also reduces the potential for carcinogenic radon gas to enter.
4.The need for an alternate ventilation device may be eliminated.
(Note: Aldes Model
An insulated 6" diameter duct is generally sufficient to provide up to 100 CFM of outside air. An adjustable damper is recommended for controlling the airflow. Large quantities of outside air will impact the
The outside air duct should be connected into the main inlet duct close to the unit. If no other inlet duct is used, locate the outside air duct end on top of and as close as possible to the
3 Operation
3.1 Humidity Control Adjustment
Set the humidity control to the desired humidity level for the home. The dehumidifier will run continuously until the relative humidity (RH) is reduced to the humidity control dial setting. Setting the humidity control to lower RH levels will NOT increase the unit's dehumidification rate; the unit will simply run longer to reduce the area's RH to the setting. The ALDES
Quality humidity meters are available from the factory and are recommended to accurately monitor humidity levels.
3.2 Blower Switch
Turning ON the fan switch will cause the unit's internal blower to run continuously, whether the unit is dehumidifying or not. This function is desirable if the unit is used for air circulation or fresh air ventilation.
4 Maintenance
4.1 Air Filters
The
If dirty, the foam prefilter can be vacuumed or carefully hand washed with warm water and mild detergent, then rinsed. The pleated fabric filter can generally be vacuumed clean several times before needing replacement. Replacement filters can be ordered from the factory or purchased locally if available. DO NOT operate the unit without the filters or with a less effective filter. The heat exchange coils inside the unit could become clogged and require disassembly to clean.
4.2 Blower Oiling
The blower motor is factory lubricated for many years of normal operation. However, periodic oiling will extend motor bearing life. To oil, remove the plastic cap from the two oiling tubes extending from the unit above the humidity control (see Figure 3). Add 3 to 5 drops of SAE 20
3