Table of Contents
Troubleshooting
Never try to repair or dismantle the dehumidifer yourself. Tampering with the unit may result in the loss of warranty and can endanger the user and property.
THANK YOU | .........1 |
Important Safeguards | 1 |
SPECIFICATIONS | 2 |
PARTS | 3 |
SPECIAL FEATURES | 4 |
Automatic Dehumidification | 4 |
Continuous Drainage | 4 |
Air Filter | 4 |
OPERATION | .........5 |
Control Panel | 5 |
Operation Instruction | 5 |
Humidity Setting | 5 |
Alarm Indicator | 5 |
Defrost | 5 |
Installing the Drainage Hose | 6 |
Maintaining Set Humidity Level | 6 |
MAINTENANCE | ....7 |
How to Take Out the Filter | 7 |
Problem
The Unit
Does Not Operate
Dehumidifying
Capacity (moisture
removal) low
Relative Humidity setting not reached after long period of operation
Cause | Solution |
No power supply. | Plug power cord firmly into outlet. |
Unit is not turned on. | Turn the unit on. |
Humidity is set lower | Set humidity higher. |
than room humidity. |
|
Air filter is dirty and/or | Clean the filter. |
blocked. |
|
Ambient room temperature | Increase the room temperature. |
too low. |
|
Poor airflow circulation/ | Improve the airflow. |
obstruction. |
|
Humidity is set lower | Set humidity higher. |
than room humidity. |
|
There are windows or | Check that the doors and windows |
doors opened. | are closed. |
Area/room is too large for |
|
the capacity of the dehumidifier |
|
Cleaning the Filter | ..........................................7 |
End of Season Storage | ....................................7 |
TROUBLESHOOTING | 9 |
WARRANTY | ......10 |
Alarm
Indicator On
Defrost Light On
The condensation discharge hose is not positioned correctly or is bent
Check if temperature is above 41 ° .
Air filter is dirty.
Air inlet/outlet grills are obsructed.
Check the hose is correctly positioned. Disconect and reconnect the appliance.
If temperature is not above 41 ° F and light still on, stop unit. Temperature is too low.
Clean Air Filter.
Clear Air Inlet/Outlet grills.
If you have any questions regarding the operation of the AD 400 E please contact AMCOR at
If this product is defective or not working properly,
please DO NOT return to your retail store. Please contact Amcor for service or technical assistance
Amcor Inc.
www.amcorgroupusa.com