Coleman LC8T-UH warranty Cabinet and Duct Dimensions, Ratings & Physical / Electrical Data, Models

Page 2

246756-CTG-C-0407

B

A

FRONT

 

 

4” Diameter

 

 

3/4

20

(VENT CONNECTIONS)

 

 

 

 

POWER WIRING

 

 

 

 

7/8” HOLE

 

 

 

13-3/4

 

14-3/4

 

 

 

2-1/2

5-3/8

 

 

 

 

 

40

 

32-1/2

 

 

 

 

 

 

 

GAS INLET

ACCESS

 

 

 

1-1/4 x 2-1/2

 

 

 

WIRING

 

 

 

 

2

 

 

 

7/8” K.O.

 

 

 

 

 

 

T’STAT WIRING

 

14

 

 

7/8” K.O.

 

 

 

 

 

 

 

 

16

 

 

 

 

 

23-1/2

2-1/4

 

 

8-3/4

 

 

 

 

 

 

1-1/8

 

30-1/8

 

 

 

 

LEFT SIDE

 

RIGHT SIDE

 

 

1-1/2

 

5/8

 

 

 

 

 

26-3/4

1-1/4

20

5/8

 

 

D

 

B

 

 

C

 

 

 

 

 

 

 

4” Diameter

24-3/4

 

 

BOTTOM IMAGE

TOP IMAGE

RETURN END

SUPPLY END

 

CABINET AND DUCT DIMENSIONS

Models

CFM

Cabinet Size

 

Cabinet Dimension

 

A

B

C

D

 

 

 

 

 

 

 

 

 

 

FC8T040A12UH11

1200

A

14 1/2

13 1/4

11 1/2

10 1/8

(F,L)C8T060A12UH11

1200

A

14 1/2

13 1/4

11 1/2

10 1/8

(F,L)C8T080A12UH11

1200

A

14 1/2

13 1/4

11 1/2

10 1/8

(F,L)C8T080B16UH11

1600

B

17 1/2

16 1/4

14 1/2

11 5/8

(F,L)C8T080C16UH11

1600

C

21

19 3/4

18

13 3/8

FC8T100B12UH11

1200

B

17 1/2

16 1/4

14 1/2

11 5/8

(F,L)C8T100C20UH11

2000

C

21

19 3/4

18

13 3/8

FC8T120C16UH11

1600

C

21

19 3/4

18

13 3/8

(F,L)C8T120C20UH11

2000

C

21

19 3/4

18

13 3/8

RATINGS & PHYSICAL / ELECTRICAL DATA

 

Input/Cabinet

Output BTU/H

Nominal

Cabinet Width

 

Blower

Blower

Models

High/Low

High/Low

Airflow

AFUE

Size

 

 

 

 

 

 

 

 

 

 

MBH

MBH

CFM

In

 

Hp

Amps

In

FC8T040A12UH11

40/26

32/21

1200

14-1/2

80.0

1/2

7.7

10 x 8

(F,L)C8T060A12UH11

57/42

46/34

1200

14-1/2

80.0

1/2

7.7

10 x 8

(F,L)C8T080A12UH11

80/59

64/48

1200

14 1/2

80.0

1/2

7.7

10 x 8

(F,L)C8T080B16UH11

80/59

64/48

1600

17-1/2

80.0

3/4

11.5

10 x 10

(F,L)C8T080C16UH11

80/59

64/48

1600

21

80.0

3/4

11.5

10 x 10

FC8T100B12UH11

100/65

80/53

1200

17 1/2

80.0

1/2

11.5

10 x 10

(F,L)C8T100C20UH11

100/65

80/53

2000

21

80.0

1

14

11 x 10

FC8T120C16UH11

120/78

96/64

1600

21

80.0

3/4

11.5

11 x 10

(F,L)C8T120C20UH11

120/78

96/64

2000

21

80.0

1

14

11 x 11

 

Input/Cabinet

Max. Outlet

Low Fire

High Fire

Unit

Max

Min. wire Size

Operation

Models

High/Low

Air Temp

Air Temp. Rise

Air Temp. Rise

Over-Current

(awg) @ 75 ft

Weight

 

 

 

 

 

Amps

Protect

one way

 

 

MBH

°F

°F

°F

Lbs

 

 

FC8T040A12UH11

40/26

150

15-45

20-50

9.0

20

14

107

(F,L)C8T060A12UH11

57/42

160

25-55

35-65

9.0

20

14

107

(F,L)C8T080A12UH11

80/52

175

30-60

40-70

9.0

20

14

117

(F,L)C8T080B16UH11

80/59

160

25-55

25-55

12.0

20

14

129

(F,L)C8T080C16UH11

80/59

160

25-55

25-55

12.0

20

14

130

FC8T100B12UH11

100/65

170

25-55

40-70

12.0

20

14

128

(F,L)C8T100C20UH11

100/65

170

25-55

40-70

12.0

20

14

145

FC8T120C16UH11

120/78

180

25-55

45-75

12.0

20

14

145

(F,L)C8T120C20UH11

120/78

170

25-55

35-65

14.0

20

12

147

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.

Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.

2

Unitary Products Group

Image 2
Contents Description WarrantyFeatures Natural GASRatings & Physical / Electrical Data Cabinet and Duct DimensionsCabinet Size Cabinet Dimension ModelsBlower Performance CFM Upflow Without Filter Bottom Return 1060 1630 1560 1490 1390 12901350 1320 1280 1230 1080 1000 950Recommended Filter Sizes Horizontal Sidewall VentingFilter Performance Filter Performance Pressure Drop Inches W.C. and KPAAccessories Applying Filter Pressure Drop to Determine System AirflowGroup Unitary ProductsNorman OK Thermostat Chart HPYork Drive All rights Reserved

FC8T-UH, LC8T-UH specifications

The Coleman LC8T-UH and FC8T-UH are versatile heating solutions designed to provide effective warmth in diverse settings, whether at home, in a workshop, or during outdoor activities. Here, we’ll explore the main features, technologies, and characteristics that make these units stand out in the crowded heating market.

Both models boast a powerful heating capacity, ensuring reliable warmth even in extreme cold conditions. Their robust design allows for efficient heating while maintaining energy efficiency, making them an economical choice for consumers mindful of their energy usage.

One of the standout characteristics of the Coleman LC8T-UH is its user-friendly control panel, which enables easy adjustments to temperature settings. The intuitive interface ensures users can quickly find their comfort level without complicated programming or excessive trial and error.

The FC8T-UH model, on the other hand, incorporates advanced heating technologies designed to maximize performance and heat distribution. This model features a patented heating element configuration that provides even warmth across a large area, ensuring no cold spots are left unattended.

Safety is paramount in the design of the LC8T-UH and FC8T-UH. Both models are equipped with multiple safety features, including overheat protection, which automatically shuts off the unit if it starts to overheat. This is particularly important for users who might leave the heater running for extended periods, offering peace of mind.

Portability is another key feature of these models. Equipped with built-in handles and lightweight construction, both the LC8T-UH and FC8T-UH can be easily moved from room to room or taken along on outdoor adventures.

Durability is a hallmark of Coleman products, and these heating units are no exception. Built with high-quality materials that withstand wear and tear, both models are designed for long-term use.

In conclusion, the Coleman LC8T-UH and FC8T-UH represent a blend of efficiency, safety, and portability, making them ideal choices for anyone in need of reliable heating solutions. Whether you’re heating your garage, workshop, or outdoor space, these models are designed to meet varied demands, ensuring comfort and warmth when it’s most needed. By combining user-friendly features with advanced technologies, Coleman continues to uphold its reputation as a leader in the heating industry.