Charnwood Charnwood Grosvenor Safety Information, Important Information, Safety Reminders

Page 2

Charnwood Grosvenor

Safety Information

Important Information

It is most important that both you, the customer and the installation engineer not only follow the instructions in this booklet, but that you are satisfied that the following conditions have been complied with.

This stove must not be used with any solid fuel, it is only suitable for natural gas or liquefied petroleum gas (LPG) according to the burner unit supplied.

Ensure that the local gas distribution conditions, the nature of the gas pressure and the adjustment of the stove are compatible.

Check that the burner data plate corresponds with the type of gas which is to be used i.e. natural gas or LPG.

The burner unit data plate is attached by a chain to the underside of the burner unit.

The site of the stove i.e. the chimney, the flue and hearth etc., must comply with current Building regulations and Codes of Practice before the stove is installed.

The chimney flue outlet must be correctly positioned to align with the flue outlet on the stove that you have bought. Connection to the chimney, the job of the installation engineer, is detailed in Section 1.

The stove must not be used with the door open.

Safety Reminders

Charnwood stoves are efficient appliances giving off convected, conducted and radiated heat. All the surfaces of the stove (except the controls,) are working surfaces and become hot in use. They must not be touched or have any combustible objects or material placed on or near them. Adequate precautions should always be taken to protect children, the elderly, the infirm and pets, etc. from coming into contact with the stove.

Technical Data

 

Gas Flow

 

 

 

 

 

Rate

 

Input

 

 

 

Burner

(m3/h)

 

(kW)

 

 

 

Natural Gas (G20)

0.42

 

4.5

 

 

 

Natural Gas (G25)

0.488

 

4.5

 

 

 

LPG (G30)

0.103

 

3.7

 

 

 

 

 

 

 

 

Burner

 

Pilot Model

Injector

Injector Pressure

Nat. Gas (G20)

P4 48 Co Pilot NG20/A/400/M9/BE

BRAY 82/280

14 mbar

Nat. Gas (G25)

P4 48 Co Pilot NG20/A/400/M9/BE

BRAY 82/280

21.5 mbar

LPG (G30)

P4 49 Co Pilot LP37/A/400/M9/BE

BRAY 92/140

16 mbar

Page 2

SV 2/00

Image 2
Contents Tel 01983 537799 Fax 01983 CHARNWOOD GROSVENOR Operating and Installation InstructionsBishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K Technical Data Charnwood Grosvenor Safety InformationSafety Reminders Important InformationGeneral Notes Flue Spillage Safety Monitoring Device A Safety Cut-Off SystemCharnwood Grosvenor Operating Instructions Lighting and controlling the stoveGlass Replacement MAINTENANCE & SERVICING PROCEDURES Stove CleaningGlass Cleaning Regular Servicing For Safety And Efficient OperationFINAL REMINDERS Problem SolvingThe gas pilot will not stay alight And Fire Opening Specification Charnwood Grosvenor Installation InstructionsAssembly Flue Spillage Monitoring SystemVentilation Gas ConnectionGas Pressure Coals Layoutø8.0 Holes Fig. 3. Coal Layer 1 Natural GasFig. 4. Coal Layer 2 Natural Gas 1st Layer below shown dottedFig. 5. Coal Layer 1 LPG Fig. 6. Coal Layers 2 & 3 LPG